Measurement Options (continued)

ICON

TYPE

PARAMETER

VALUE TO SET, COMMENTS

ViSession vi

Session 

handle

ViInt32 AutoZero

Default 

Auto

ViSession vi

Session 

handle

ViInt32 ADC 

Calibration 

Default 

Auto

ViSession vi 

Session 

handle

ViInt32 

Offset Compensated

Default = Off

Ohms

ViSession

vi

Session handle

ViReal64 Minimum 

Frequency Hz

ViReal64 Maximum 

Frequency Hz

ViSession vi 

Session 

handle

ViReal64 Frequency 

Voltage

Default 

AutoRange

Range

ViSession

vi

Session handle

ViReal64 

Current Source 

Default = 1.00 mA

ViSession

vi

Session handle

ViInt32 

Waveform 

AC or DC

Coupling

niDMM Configure Waveform Coupling

(niDMM_ConfigureWaveformCoupling)

Configures instrument coupling for voltage waveforms on the NI 4070/4071/4072.

niDMM Configure Current Source

(niDMM_ConfigureCurrentSource)

Configures the current source for diode measurements on the NI 4070/4071/4072.

niDMM Configure Frequency Voltage Range

(niDMM_ConfigureFrequencyVoltageRange)

Specifies the expected maximum amplitude of the input signal for frequency and
period measurements on the NI 4070/4071/4072.

niDMM Configure AC Bandwidth

(niDMM_ConfigureACBandwidth)

Configures the Min Frequency and Max Frequency properties that the DMM uses
for AC measurements.

niDMM Configure Offset Comp Ohms

(niDMM_ConfigureOffsetCompOhms)

Allows the NI 4070/4071/4072 to compensate for voltage offsets in resistance
measurements.

niDMM Configure ADC Calibration

(niDMM_ConfigureADCCalibration)

Allows the NI 4070/4071/4072 to compensate for gain drift since the last external or 
self-calibration.

niDMM Configure Auto Zero

(niDMM_ConfigureAutoZeroMode)

Configures the DMM for Auto Zero.

©

National Instruments Corporation

3

NI-DMM Instrument Driver Quick Reference

322614f.qxp  11/23/2004  10:13 AM  Page 3

Содержание Instrument Driver NI-DMM

Страница 1: ...name ViBoolean IDQuery NIDMM_VAL_TRUE NIDMM_VAL_FALSE ViBoolean resetDevice NIDMM_VAL_TRUE NIDMM_VAL_FALSE ViString Option String Simulate 0 RangeCheck 1 QueryInstrStatus 1 Cache 1 ViSession vi Refer...

Страница 2: ...te ViInt32 WaveformPoints Measurement Options ICON TYPE PARAMETER VALUE TO SET COMMENTS ViSession vi Session handle ViReal64 Powerline Default 60 Hz Frequency niDMM Configure Powerline Frequency niDMM...

Страница 3: ...entSource Configures the current source for diode measurements on the NI 4070 4071 4072 niDMM Configure Frequency Voltage Range niDMM_ConfigureFrequencyVoltageRange Specifies the expected maximum ampl...

Страница 4: ...e values on the NI 4072 niDMM Perform Open Cable Comp niDMM_PerformOpenCableComp Performs the open cable compensation measurements and returns open cable compensation conductance and susceptance value...

Страница 5: ...to either rising edge or falling edge polarity niDMM Configure Meas Complete Dest niDMM_ConfigureMeasCompleteDest Specifies the destination of the Measurement Complete MC signal niDMM Configure Sampl...

Страница 6: ...s ViInt32 Number to Read Default 4 ViReal64 Measurements Output ViInt32 Actual Number Output niDMM Read Multi Point niDMM_ReadMultiPoint Acquires multiple measurements and returns an array of measured...

Страница 7: ...surements Output ViInt32 Actual Number Output niDMM Fetch Multi Point niDMM_FetchMultiPoint Returns an array of values from a previously initiated multipoint measurement niDMM Fetch niDMM_Fetch Return...

Страница 8: ...are Revision Output niDMM Revision Query niDMM_revision_query Returns the revision numbers of the instrument driver and instrument firmware niDMM Self Test niDMM_self_test Performs a self test on the...

Страница 9: ...nal ViInt32 Count Output niDMM Get Cal Count niDMM_GetCalCount Returns the calibration count for the specified type of calibration niDMM Self Cal niDMM_SelfCal Executes the self calibration routine to...

Страница 10: ...put ViInt32 Year Output ViInt32 Hour Output ViInt32 Minute Output niDMM Get Cal Date and Time niDMM_GetCalDateAndTime Returns the date and time of the last calibration performed on the NI 4070 4071 40...

Страница 11: ...nts Corporation 11 NI DMM Instrument Driver Quick Reference National Instruments Corporation Initialize Configure Hardware Read Close Session Initiate Fetch DMM Programming Flow 322614f qxp 11 23 2004...

Страница 12: ...ther product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products refer to the appropriate location Help Pa...

Отзывы: