Getting Started with the NI PXI/PCI-1409

Measurement Category

1

: Measurement circuits are subjected to working voltages

2

 and transient 

stresses (overvoltage) from the circuit to which they are connected during measurement or test. 
Measurement Category establishes standardized impulse withstand voltage levels that commonly occur 
in electrical distribution systems. The following is a description of Measurement (Installation

3

Categories:

Measurement Category I is for measurements performed on circuits 

not

 directly connected to the 

electrical distribution system referred to as MAINS

4

 voltage. This category is for measurements of 

voltages from specially protected secondary circuits. Such voltage measurements include signal 
levels, special equipment, limited-energy parts of equipment, circuits powered by regulated 
low-voltage sources, and electronics.

Measurement Category II is for measurements performed on circuits directly connected to the 
electrical distribution system. This category refers to local-level electrical distribution, such as that 
provided by a standard wall outlet (e.g., 115 V for U.S. or 230 V for Europe). Examples of 
Measurement Category II are measurements performed on household appliances, portable tools, 
and similar products.

Measurement Category III is for measurements performed in the building installation at the 
distribution level. This category refers to measurements on hard-wired equipment such as 
equipment in fixed installations, distribution boards, and circuit breakers. Other examples are 
wiring, including cables, bus-bars, junction boxes, switches, socket-outlets in the fixed installation, 
and stationary motors with permanent connections to fixed installations.

Unpacking

The NI 1409 ships in an antistatic package to prevent electrostatic discharge from damaging device 
components. To avoid such damage in handling the device, take the following precautions:

1.

Ground yourself using a grounding strap or by touching a grounded object, such as the computer 
chassis.

2.

Touch the antistatic package to a metal part of the computer chassis before removing the device 
from the package.

Caution

Never

 touch the exposed pins of connectors.

3.

Remove the device from the package and inspect it for loose components or any other signs of 
damage. Notify National Instruments if the device appears damaged in any way. Do 

not

 install a 

damaged device in the computer.

Store the NI 1409 in the antistatic package when not in use.

Installation

The following instructions are for general installation. Refer to the documentation provided by your 
computer manufacturer for specific instructions and warnings. Refer to the 

Specifications

 section for 

typical power requirements for the NI 1409.

1   

Measurement Categories as defined in electrical safety standard IEC 61010-1.

2   

Working voltage is the highest rms value of an AC or DC voltage that can occur across any particular insulation.

3   

Measurement Category is also referred to as Installation Category.

4   

MAINS is defined as the (hazardous live) electrical supply system to which equipment is designed to be connected for the 
purpose of powering the equipment. Suitably rated measuring circuits may be connected to the MAINS for measuring 
purposes.

Содержание IMAQ PXI-1409

Страница 1: ...Vista NI Vision Acquisition Software 8 0 or later which includes the NI IMAQ driver software Optional software for developing applications NI Vision Builder for Automated Inspection NI Vision Developm...

Страница 2: ...f introducing additional hazards do not install unauthorized parts or modify the device Use the device only with the chassis modules accessories and cables specified in the installation instructions A...

Страница 3: ...ircuit breakers Other examples are wiring including cables bus bars junction boxes switches socket outlets in the fixed installation and stationary motors with permanent connections to fixed installat...

Страница 4: ...or handle to fully inject the device into place 8 Secure the front panel of the NI PXI 1409 to the front panel mounting rails of the PXI or CompactPCI chassis 9 Connect the BNC cable included with the...

Страница 5: ...nt Automation Explorer MAX the National Instruments configuration utility to configure the NI 1409 for acquisition Refer to the Measurement Automation Explorer Help for NI IMAQ for additional informat...

Страница 6: ...eo sources 5 Pixel jitter 2 ns peak PCI Interface PCI initiator master capability Supported PCI target slave capability Supported Data path 32 bits Card voltage 5 V only Card type 32 bit half size car...

Страница 7: ...IL STD 810E Method 514 Test levels exceed those recommended in MIL STD 810E for Category 1 Basic Transportation Figures 514 4 1 through 514 4 3 Approved at altitudes up to 2 000 m Safety This product...

Страница 8: ...assistance from NI Application Engineers A Declaration of Conformity DoC is our claim of compliance with the Council of the European Communities using the manufacturer s declaration of conformity Thi...

Отзывы: