Safety Guidelines for Hazardous Voltages
If
hazardous voltages
are connected to the module, take the
following precautions. A hazardous voltage is a voltage greater
than 42.4 V
peak
or 60 VDC to earth ground.
Caution
Ensure that hazardous voltage wiring is
performed only by qualified personnel adhering to local
electrical standards.
Caution
Do
not
mix hazardous voltage circuits and
human-accessible circuits on the same module.
Caution
Make sure that devices and circuits connected to
the module are properly insulated from human contact.
Caution
When terminals on the connector block are live
with hazardous voltages, make sure that the terminals are
not
accessible.
Specifications
The following specifications are typical for the range –40 to 70 °C
unless otherwise noted. Gain errors are given as a percentage of
input signal value. Specifications are subject to change without
notice.
Input Characteristics
Number of channels.......................... 8
ADC resolution................................. 16 bits at 50 or 60 Hz;
10 bits at 500 Hz
Type of ADC..................................... Delta-sigma