Shock and Vibration
To meet these specifications, you must panel mount the system.
Operating vibration
...................................................
Random (IEC
60068-2-64)
5 g
rms
, 10 Hz to 500 Hz
...................................................
Sinusoidal (IEC
60068-2-6)
5 g, 10 Hz to 500 Hz
...........................................................
Operating shock (IEC
60068-2-27)
30 g, 11 ms half sine; 50 g,
3 ms half sine;
18 shocks at 6 orientations
Environmental
Refer to the manual for the chassis you are using for more
information about meeting these specifications.
...........................................................
Operating temperature
(IEC 60068-2-1, IEC 60068-2-2)
-40 °C to 70 °C
...........................................................
Storage temperature
(IEC 60068-2-1, IEC 60068-2-2)
-40 °C to 85 °C