background image

Worldwide Support and Services

The NI website is your complete resource for technical support.
At 

ni.com/support

, you have access to everything from

troubleshooting and application development self-help resources
to email and phone assistance from NI Application Engineers.

Visit 

ni.com/services

 for NI Factory Installation Services, repairs,

extended warranty, and other services.

Visit 

ni.com/register

 to register your NI product. Product

registration facilitates technical support and ensures that you
receive important information updates from NI.

A Declaration of Conformity (DoC) is our claim of compliance
with the Council of the European Communities using the
manufacturer’s declaration of conformity. This system affords the
user protection for electromagnetic compatibility (EMC) and
product safety. You can obtain the DoC for your product by
visiting 

ni.com/certification

. If your product supports calibration,

you can obtain the calibration certificate for your product at 

ni.com/calibration

.

20

  | 

ni.com

  | 

NI 9229 Getting Started Guide

Содержание 9229

Страница 1: ...GETTING STARTED GUIDE NI 9229 4 AI 60 V 24 Bit 50 kS s ch Simultaneous ...

Страница 2: ... Refer to the documentation for each component in the system to determine the safety and EMC ratings for the entire system Safety Guidelines Operate the NI 9229 only as described in this document Caution Do not operate the NI 9229 in a manner not specified in this document Product misuse can result in a hazard You can compromise the safety protection built into the product if the product is damage...

Страница 3: ...tages Connect only voltages that are within the following limits Isolation Channel to channel Continuous 250 Vrms Measurement Category II Withstand 1 390 V verified by a 5 s dielectric withstand test Channel to earth ground Continuous 250 Vrms Measurement Category II Withstand 2 300 V verified by a 5 s dielectric withstand test NI 9229 Getting Started Guide National Instruments 3 ...

Страница 4: ...ary circuits Such voltage measurements include signal levels special equipment limited energy parts of equipment circuits powered by regulated low voltage sources and electronics Note Measurement Categories CAT I and CAT O are equivalent These test and measurement circuits are not intended for direct connection to the MAINS building installations of Measurement Categories CAT II CAT III or CAT IV ...

Страница 5: ...t provided by a standard wall outlet for example 115 V for U S or 230 V for Europe Caution Do not connect the NI 9229 with screw terminal to signals or use for measurements within Measurement Categories III or IV NI 9229 with BNC Safety Voltages Connect only voltages that are within the following limits Isolation Channel to channel Continuous 60 VDC Measurement Category I Withstand 1 000 V verifie...

Страница 6: ...hat powers equipment This category is for measurements of voltages from specially protected secondary circuits Such voltage measurements include signal levels special equipment limited energy parts of equipment circuits powered by regulated low voltage sources and electronics Note Measurement Categories CAT I and CAT O are equivalent These test and measurement circuits are not intended for direct ...

Страница 7: ...recautions A hazardous voltage is a voltage greater than 42 4 Vpk voltage or 60 VDC to earth ground Caution Ensure that hazardous voltage wiring is performed only by qualified personnel adhering to local electrical standards Caution Do not mix hazardous voltage circuits and human accessible circuits on the same module Caution Ensure that devices and circuits connected to the module are properly in...

Страница 8: ...azardous locations and nonhazardous locations only Follow these guidelines if you are installing the NI 9229 in a potentially explosive environment Not following these guidelines may result in serious injury or death Caution Do not disconnect I O side wires or connectors unless power has been switched off or the area is known to be nonhazardous Caution Do not remove modules unless power has been s...

Страница 9: ...thin 84 VDC to earth ground if there is a transient overvoltage condition Caution For Division 2 and Zone 2 applications connected voltage sources must be within 60 VDC to earth ground Caution For Division 2 and Zone 2 applications connected signals must be within the following limits Capacitance 0 01 μF max Special Conditions for Hazardous Locations Use in Europe and Internationally The NI 9229 h...

Страница 10: ...T4 or Ex nL IIC T4 equipment Caution You must make sure that transient disturbances do not exceed 140 of the rated voltage Caution The system shall only be used in an area of not more than Pollution Degree 2 as defined in IEC 60664 1 Caution The system shall be mounted in an ATEX IECEx certified enclosure with a minimum ingress protection rating of at least IP54 as defined in IEC EN 60079 15 Cauti...

Страница 11: ...owever harmful interference may occur in some installations when the product is connected to a peripheral device or test object or if the product is used in residential or commercial areas To minimize interference with radio and television reception and prevent unacceptable performance degradation install and use this product in strict accordance with the instructions in the product documentation ...

Страница 12: ...NI part number 782801 01 in accordance with the product installation instructions Refer to the NI 9229 product page on ni com for purchasing information about clamp on ferrite beads Cable Requirements for EMC Compliance Select and install cables for the NI 9229 with BNC in accordance with the following requirements Install a clamp on ferrite bead NI part number 782801 01 on the BNC cable for each ...

Страница 13: ...Lloyd s Register LR Type Approved for marine shipboard applications To verify Lloyd s Register certification for a product visit ni com certification and search for the LR certificate or look for the Lloyd s Register mark on the product Caution In order to meet the EMC requirements for marine applications install the product in a shielded NI 9229 Getting Started Guide National Instruments 13 ...

Страница 14: ...paring the Environment Ensure that the environment in which you are using the NI 9229 meets the following specifications Operating temperature IEC 60068 2 1 IEC 60068 2 2 40 C to 70 C Operating humidity IEC 60068 2 78 10 RH to 90 RH noncondensing Pollution Degree 2 Maximum altitude 2 000 m Indoor use only Note Refer to the device datasheet on ni com manuals for complete specifications 14 ni com NI...

Страница 15: ...NI 9229 Pinout AI0 AI0 AI1 AI1 AI2 AI2 AI3 AI3 0 1 0 1 0 1 0 1 AI0 AI0 AI1 AI1 AI2 AI2 AI3 AI3 NI 9229 Getting Started Guide National Instruments 15 ...

Страница 16: ...ignal connection AI Negative analog input signal connection Grounded Connections NI 9229 Signal Source AI AI Make sure the voltage on the AI and AI connections are in the channel to earth safety voltage range to ensure proper operation 16 ni com NI 9229 Getting Started Guide ...

Страница 17: ... that devices you connect to the NI 9229 are compatible with the module specifications You must use 2 wire ferrules to create a secure connection when connecting more than one wire to a single terminal on the NI 9229 with screw terminal NI 9229 Getting Started Guide National Instruments 17 ...

Страница 18: ...ons to the NI 9229 with screw terminal Use ferrules to terminate wires to the detachable connector Use the NI 9971 backshell kit Overvoltage Protection The NI 9229 provides overvoltage protection for each channel Note Refer to the device datasheet on ni com manuals for more information about overvoltage protection 18 ni com NI 9229 Getting Started Guide ...

Страница 19: ...CompactRIO NI CompactDAQ RELATED INFORMATION NI 9229 Datasheet NI RIO Help LabVIEW FPGA Help NI 9229 Datasheet NI DAQmx Help LabVIEW Help Services ni com services C Series Documentation Resources ni com info cseriesdoc NI 9229 Getting Started Guide National Instruments 19 ...

Страница 20: ...r NI product Product registration facilitates technical support and ensures that you receive important information updates from NI A Declaration of Conformity DoC is our claim of compliance with the Council of the European Communities using the manufacturer s declaration of conformity This system affords the user protection for electromagnetic compatibility EMC and product safety You can obtain th...

Страница 21: ...ates create your service request at ni com support or dial 1 866 ASK MYNI 275 6964 For telephone support outside the United States visit the Worldwide Offices section of ni com niglobal to access the branch office websites which provide up to date contact information support phone numbers email addresses and current events NI 9229 Getting Started Guide National Instruments 21 ...

Страница 22: ...party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal export compliance for the NI global trade compliance policy and how to obtain relevant HTS codes ECCNs and other import export data NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS U S Government...

Отзывы: