background image

Figure 15.

 Installing the NI FlexRIO Adapter Module

PXI-1000B

1

4

3

2

5

1. NI FlexRIO Adapter Module
2. Captive Screw
3. Guide Pin

4. PXI/PXI Express Chassis
5. NI FlexRIO FPGA Module

The connection may be tight, but do not force the adapter module into place.

2.

Tighten the captive screws on the NI FlexRIO adapter module to secure it to the
NI FlexRIO FPGA module. NI recommends using the laser-tipped screwdriver (part
number 748677-01) included in the NI 6587 packaging.

3.

Launch LabVIEW to begin configuring your NI FlexRIO system.

Installing PXI EMC Filler Panels

To ensure specified EMC performance, PXI EMC filler panels must be properly installed in
your NI FlexRIO system. The PXI EMC filler panels (National Instruments part number
778700-01) must be purchased separately.
1.

Remove the captive screw covers.

2.

Install the PXI EMC filler panels by securing the captive mounting screws to the chassis,
as shown in the figure below. Make sure that the EMC gasket is on the right side of the
PXI EMC filler panel.

24

  | 

ni.com

  | 

NI 6587 Getting Started Guide

Содержание 6587

Страница 1: ...our NI 6587 you must install the appropriate software and hardware Refer to the getting started guide for your NI FlexRIO FPGA module for installation instructions The following figure shows an example of a properly connected NI FlexRIO device Figure 1 NI FlexRIO Device NI FlexRIO Adapter Module NI FlexRIO Device NI FlexRIO FPGA Module Contents Electromagnetic Compatibility Guidelines 2 How to Use...

Страница 2: ... operated in the intended operational electromagnetic environment This product is intended for use in industrial locations However harmful interference may occur in some installations when the product is connected to a peripheral device or test object or if the product is used in residential or commercial areas To minimize interference with radio and television reception and prevent unacceptable p...

Страница 3: ...GA module NI FlexRIO Adapter Module Development Kit User Manual Table 1 NI FlexRIO Documentation Locations and Descriptions Document Location Description Getting started guide for your FPGA module Available from the Start menu and at ni com manuals Contains installation instructions for your NI FlexRIO system Specifications document for your FPGA module Available from the Start menu and at ni com ...

Страница 4: ...se with NI FlexRIO FPGA modules LabVIEW Examples Available in NI Example Finder In LabVIEW click Help Find Examples Hardware Input and Output FlexRIO Contains examples of how to run FPGA VIs and Host VIs on your device IPNet ni com ipnet Contains LabVIEW FPGA functions and intellectual property to share NI FlexRIO product page ni com flexrio Contains product information and data sheets for NI Flex...

Страница 5: ...K IN 1 Gbps LVDS GND PFI 1 GND PFI 2 GND PFI 3 GND GND DIO 0 GND DIO 1 GND DIO 2 GND DIO 3 GND DIO 4 GND DIO 5 GND DIO 6 GND DIO 7 GND DIO 8 GND DIO 9 GND DIO 10 GND DIO 11 GND DIO 12 GND DIO 13 GND DIO 14 GND DIO 15 GND GND GND GND GND PFI 1 PFI 2 PFI 3 DIO 0 DIO 1 DIO 2 DIO 3 DIO 4 DIO 5 DIO 6 DIO 7 DIO 8 DIO 9 DIO 10 DIO 11 DIO 12 DIO 13 DIO 14 DIO 15 1 3 2 4 6 5 7 9 8 10 12 11 13 15 14 16 18 1...

Страница 6: ...mation for the SMA connectors on the NI 6587 Table 2 SMA Connector Names and Descriptions Signal Name Connector Signal Type Signal Description PFI 0 PFI 0 Control Bidirectional single ended terminal for channel PFI 0 CLOCK IN CLOCK IN Clock External single ended clock input terminal The following table contains pin location information and signal information for the DDC connectors on the NI 6587 T...

Страница 7: ...channels 1 through 4 SE_PFI 1 3 68 71 72 Control Single ended terminals for bidirectional PFI channels 1 through 3 GND 1 4 7 10 13 16 19 22 25 28 31 34 37 40 42 46 49 52 55 58 69 Ground Ground reference for signals For more detailed information about the NI 6587 front panel connectors refer to the NI 6587 Specifications Block Diagrams Figures 4 through 8 show the data flow through the NI 6587 Sing...

Страница 8: ...1 4 Figure 6 Single Ended PFI Lines Data from NI FlexRIO FPGA Module GPIO Output Output Enable from NI FlexRIO FPGA Module GPIO Direction Data to NI FlexRIO FPGA Module GPIO Input SE_PFI 1 3 and PFI 0 50 Ohm Figure 7 Clock Output Signals Clock from NI FlexRIO FPGA Module GPIO Output Output Enable from NI FlexRIO FPGA Module GPIO Direction DDC CLK OUT LVDS LVDS DDC CLK OUT Switch 110 Ohm 10 kOhm 10...

Страница 9: ...6587 Component Level Intellectual Property CLIP The LabVIEW FPGA Module includes component level intellectual property CLIP for HDL IP integration NI FlexRIO devices support two types of CLIP user defined and socketed User defined CLIP allows you to insert HDL IP into an FPGA target enabling VHDL code to communicate directly with an FPGA VI Socketed CLIP provides the same IP integration of the use...

Страница 10: ...IP DRAM 1 CLIP Socket Socketed CLIP Fixed I O Fixed I O DRAM 0 DRAM 1 The NI 6587 ships with socketed CLIP items that add module I O to the LabVIEW project Related Information Block Diagrams on page 7 NI 6587 CLIP Refer to the following table for the available NI 6587 CLIP items and each CLIP item s function and available signals Note All NI 6587 CLIP items allow individual clock output inversion ...

Страница 11: ...ata LVDS lines Four LVDS PFI lines One LVDS STROBE line One LVDS clock output signal Four single ended PFI lines One single ended clock input signal Provides read write access to all LVDS and single ended channels using a channel based interface You can access the LVDS data and PFI channels using a U16 data type in which the top six bits are unused Each LVDS line PFI line and clock output is conne...

Страница 12: ... or deserializes respectively the signal by a factor of six by default Therefore with every regional clock cycle the NI 6587 reads or writes six samples to or from the ISERDES or OSERDES blocks All OSERDES and ISERDES blocks are set to double data rate DDR mode The following table lists the NI 6587 SMA connector signals and corresponding NI FlexRIO FPGA module signals necessary for designing custo...

Страница 13: ...GPIO_48 GPIO_15_n PFI 4 GPIO_47_n GPIO_48_n DIO 0 GPIO_62 GPIO_32 GPIO_4_n DIO 0 GPIO_62_n GPIO_32_n DIO 1 GPIO_63 GPIO_28 GPIO_11 DIO 1 GPIO_63_n GPIO_28_n DIO 2 GPIO_64 GPIO_23 GPIO_9_n DIO 2 GPIO_64_n GPIO_23_n DIO 3 GPIO_65 GPIO_19 GPIO_3 DIO 3 GPIO_65_n GPIO_19_n DIO 4 GPIO_60 GPIO_31 GPIO_4 DIO 4 GPIO_60_n GPIO_31_n DIO 5 GPIO_61 GPIO_27 GPIO_5 DIO 5 GPIO_61_n GPIO_27_n DIO 6 GPIO_55 GPIO_22...

Страница 14: ... DIO 9 GPIO_52_n GPIO_25_n DIO 10 GPIO_51 GPIO_21 GPIO_10 DIO 10 GPIO_51_n GPIO_21_n DIO 11 GPIO_50 GPIO_17 GPIO_2 DIO 11 GPIO_50_n GPIO_17_n DIO 12 GPIO_49_CC GPIO_29 GPIO_12 DIO 12 GPIO_49_n_CC GPIO_29_n DIO 13 GPIO_57_CC GPIO_24 GPIO_13 DIO 13 GPIO_57_n_CC GPIO_24_n DIO 14 GPIO_58_CC GPIO_20 GPIO_3_n DIO 14 GPIO_58_n_CC GPIO_20_n DIO 15 GPIO_59_CC GPIO_16 GPIO_1_n DIO 15 GPIO_59_n_CC GPIO_16_n ...

Страница 15: ...a list of available socketed CLIP signals Cables Caution You must operate the NI 6587 with shielded cables and shielded accessories to ensure compliance with the EMC requirements defined in the NI 6587 Specifications Do not use unshielded cables or accessories unless they are installed in a shielded enclosure with properly designed and shielded input output ports and are connected to the NI 6587 u...

Страница 16: ...on pin 1 maps to pin 73 at the end connector The following NI cables and accessories are not properly shielded for EMC compliant use with the NI 6587 NI SMA 2164 accessory NI SHB12X H3X24 differential flying lead cable Note Whether you use NI cables and accessories or design your own terminate cables properly to avoid improper measurements caused by signal reflections overshoot and undershoot Acce...

Страница 17: ...2164 DIFFERENTIAL DIGITAL I O ACCESSORY FOR PATENTS NI COM PATENTS COPYRIGHT 2005 NI 6587 PFI 0 CLOCK IN 1 Gbps LVDS 1 PXI PXIe Chassis with an NI 6587R 2 NI SHB12 B12X Cable 3 NI SMA 2164 A flying lead cable the NI SHB12X H3X24 is also available for differential signals This cable offers connectivity similar to that found on a typical logic analyzer so you can use it in logic analyzer type applic...

Страница 18: ...or example the signal shown on pin 1 maps to pin 73 at the end connector For more information about connecting I O signals on your device refer to the NI 6587 Specifications Related Information http www ni com info Clocking The clocks on the NI 6587 control the sample rate and other timing functions on your NI FlexRIO system The following figure shows the NI 6587 clock sources routed through the c...

Страница 19: ...the values of the crosspoint switch clock options Table 7 Clock Values Value Clock Option 0 Tristate Output disabled high impedance 2 Sync Clock PXI Express Only Clock from PXI Express backplane You can select PXI_CLK10 or DStarA in the Details category of the IO Module Properties dialog box 3 Adapter Module Onboard Clock Clock generated from the Si570 clock chip 4 Strobe From Crosspoint Switch LV...

Страница 20: ... selecting Start All Programs National Instruments LabVIEW LabVIEW Manuals 3 Optional Install the LabVIEW Real Time Module Refer to the LabVIEW Real Time Module Release and Upgrade Notes for system requirements installation instructions and additional information about using the LabVIEW Real Time Module 4 Install NI FlexRIO Refer to the NI FlexRIO Readme on the NI FlexRIO installation media for sy...

Страница 21: ... module into the chassis Preparing the Environment Ensure that the environment you are using the NI 6587 in meets the following specifications Operating temperature IEC 60068 2 1 IEC 60068 2 2 0 C to 55 C Operating humidity IEC 60068 2 56 10 to 90 RH noncondensing Pollution Degree 2 Maximum altitude 2 000 m at 25 C ambient temperature Indoor use only Note Refer to the NI 6587 Specifications at ni ...

Страница 22: ...ny static electricity Place the PXI Express module edges into the module guides at the top and bottom of the chassis and slide the module into the chassis until the module is fully inserted as shown in the figure below Figure 14 Installing an NI FlexRIO FPGA Module in the PXI Express Chassis PXI 1000B 1 3 6 2 5 4 1 PXI Express Chassis 2 PXI Express System Controller 3 NI FlexRIO FPGA Module 4 Fron...

Страница 23: ... list of installed devices Installed devices appear under the name of their associated chassis 3 Expand your Chassis tree item MAX lists all devices installed in the chassis Your default device names may vary Note If you do not see your hardware listed press F5 to refresh the list of installed devices If the device is still not listed power off the system ensure the device is correctly installed a...

Страница 24: ... 748677 01 included in the NI 6587 packaging 3 Launch LabVIEW to begin configuring your NI FlexRIO system Installing PXI EMC Filler Panels To ensure specified EMC performance PXI EMC filler panels must be properly installed in your NI FlexRIO system The PXI EMC filler panels National Instruments part number 778700 01 must be purchased separately 1 Remove the captive screw covers 2 Install the PXI ...

Страница 25: ...ratures and cause burns Allow the module to cool before removing it from the chassis 1 Caution Disconnect or disable any external RF clock or digital connections to the NI 6587 front panel Applying external signals while the device is powered off may cause damage Disconnect any cables from the module front panel connectors 2 Power off the chassis 3 Ground yourself with a grounding strap or touch a...

Страница 26: ...e Environment Ambient temperature range 20 C to 70 C Tested in accordance with IEC 60068 2 1 and IEC 60068 2 2 Meets MIL PRF 28800F Class 3 limits Relative humidity range 5 to 95 noncondensing Tested in accordance with IEC 60068 2 56 Shock and Vibration Operating shock 30 g peak half sine 11 ms pulse Tested in accordance with IEC 60068 2 27 Meets MIL PRF 28800F Class 2 limits Random vibration Oper...

Страница 27: ...ustrial locations In Europe Canada Australia and New Zealand per CISPR 11 Class A equipment is intended for use only in heavy industrial locations Note Group 1 equipment per CISPR 11 is any industrial scientific or medical equipment that does not intentionally generate radio frequency energy for the treatment of material or inspection analysis purposes Note For EMC declarations certifications and ...

Страница 28: ...HS 中国客户 National Instruments 符合中国电子信息产品中限制使用某些有害物 质指令 RoHS 关于 National Instruments 中国 RoHS 合规性信息 请登录 ni com environment rohs_china For information about China RoHS compliance go to ni com environment rohs_china Where to Go Next Refer to the following figure for information about other product tasks and associated resources for those tasks custom applications within an application programming inter...

Страница 29: ...s declaration of conformity This system affords the user protection for electromagnetic compatibility EMC and product safety You can obtain the DoC for your product by visiting ni com certification If your product supports calibration you can obtain the calibration certificate for your product at ni com calibration National Instruments corporate headquarters is located at 11500 North Mopac Express...

Страница 30: ... and third party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal export compliance for the National Instruments global trade compliance policy and how to obtain relevant HTS codes ECCNs and other import export data NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE ...

Отзывы: