![National Flooring Equipment DL4000 Скачать руководство пользователя страница 20](http://html2.mh-extra.com/html/national-flooring-equipment/dl4000/dl4000_instruction-manual_3378141020.webp)
Operation Section
- 17 -
➢
This specific model is equipped with two sockets for auxiliary equipment connection. (See 3.2
Description of controls.) On the right side of the dust collector there is a 230V three-phase socket and
on the left side a 230V single-phase socket. On the panel there is a switch for socket selection (it is
possible to use
only one socket
at a time). When the dust collector is on it supplies power to the
panel; after having selected the socket to be used, it is possible to connect the auxiliary equipment to
the socket selected. Remember that the user cannot use to both sockets simultaneously.
➢
To move the dust collector, use the handles.
Warning!
The dust collector can be moved only on flat ground!
If the dust collector is moved on inclined ground, you can risk to lose the control, because of the weight
and to damage persons or things.
Warning!
During vacuuming, avoid rolling up or bending the flexible hose.