National Comfort Product 1000 SERIES Скачать руководство пользователя страница 16

16

National Comfort Products

539 Dunksferry Road • Bensalem, PA 19020 • (215) 244-1400 • 1-800-523-7138 • Fax: (215) 244-9579

DESCRIPTION

NCPD-418

NCPD-424

1

2

 

3

4

Contactor

Dual Run Capacitor

30-5 mFd / 370V

35-5 mFd / 370V

 

Low Pressure Switch

High Pressure Switch

14262082

14225376

 

14265026

14265027

14262082

14225375

 

14265026

14265027

5

Compressor

H82J15BABCA

H82J19BABCA

14210102

14210215

6

7

Liquid Service Valve

Vapor Service Valve

14258603A

14258606A

14258603A

14258606A

8

9

10

11

12

13  

 

14 

 

15 

 

16 

 

17 

 

18 

Outdoor Coil

Motor

0.25 HP 1500 RPM

14” Prop Fan

Motor Mount

Access Panel 1000

Top Panel 1000 

 

Right Side Panel 

 

Left Side Panel 

 

Wire Grille 1000 

 

Radial Fan Mount 

 

Touch Up Paint

14208360

 

14270049

14214033

14270102 

14256318

14256316 

 

14256315 

 

14256314 

 

14256001A 

 

14256317 

 

14299630

14208361

 

14270049

14214033

14270102

14256318

14256316 

 

14256315 

 

14256314 

 

14256001A 

 

14256317 

 

14299630

REPLACEMENT PARTS GUIDE     

      

NCPD SERIES 1000

NCPD1000/D SERIES

ITEM

DESCRIPTION

4000 SERIES

19

20 

 

20A

21

22

23 

 

23A

Time Relay on Make

Crankcase Heater Bristol

Crankcase Heater Copeland 

 

Low Ambient Control

Hard Start Kit

Compressor Cover Bristol 

 

Compressor Cover Copeland

14262054

14206023 

 

14206033

14260017

14216307

14210053 

 

14210221

**ADDITIONAL PARTS - MADISON SERIES ONLY

Содержание 1000 SERIES

Страница 1: ...Wall Installation If the optional wall sleeve is used caulk the spaces between the sleeve and the wall Completely fill the clearance between the unit and the wall sleeve with a polyurethane foam seala...

Страница 2: ...fully charged at the factory for the recom mended model of indoor unit With other models of indoor units the charge must be adjusted Be sure both service valves are closed during tubing installation...

Страница 3: ...alloy is used Step 5 This is not a back seating valve To open the valve re move the valve cap with an adjustable wrench Insert a 3 16 or 5 16 hex wrench into the stem Back out counter clockwise until...

Страница 4: ...into the system NOTE Oil charge is polyester 32bce 3 When the correct refrigerant charge level is obtained remove the manifold gauge set 4 Replace the gauge port caps Permanently stamp the unit data...

Страница 5: ...or tight ness balance and rust or corrosion 8 Inspect wire connection for evidence of arcing overheating and deterioration Sequence of Operations for Madison Avenue Option Step 7 Maintenance The compr...

Страница 6: ...6 Wiring Schematic NCPD XXX 1010 D NCPD XXX 3010 D Bristol Compressor MODEL CAPACITOR NCPD 418 30ufd 370VAC NCPD 424 35ufd 370VAC NCPD 430 35ufd 370VAC...

Страница 7: ...7 Wiring Schematic NCPE XXX 1010 NCPE XXX 3010 NCPE XXX 4010 Copeland Compressor MODEL CAPACITOR NCPE 418 30ufd 370VAC NCPE 424 35ufd 370VAC NCPE 430 40ufd 370VAC...

Страница 8: ...8 Wiring Schematic NCPE XXX 1010 D NCPE XXX 3010 D NCPE XXX 4010 D Copeland Compressor NCPE 430 XXXX D MODEL CAPACITOR NCPE 418 30ufd 370VAC NCPE 424 35ufd 370VAC NCPE 430 40ufd 370VAC...

Страница 9: ...9 Wiring Schematic NCPD XXX 1010 D NCPD XXX 3010 D Bristol Compressor MODEL CAPACITOR NCPD 418 30ufd 370VAC NCPD 424 35ufd 370VAC NCPD 430 35ufd 370VAC...

Страница 10: ...10 Wiring Schematic NCPD XXX 4010 NCPDXXX 4010 Bristol Compressor MODEL CAPACITOR NCPD 418 30ufd 370VAC NCPD 424 35ufd 370VAC NCPD 430 35ufd 370VAC...

Страница 11: ...11 Wiring Schematic NCPE XXX 4010 Bristol Compressor MODEL CAPACITOR NCPE 418 30ufd 370VAC NCPE 424 35ufd 370VAC...

Страница 12: ...12 Wiring Schematic NCPE XXX 4010 D 30uFd 350VAC Bristol Compressor MODEL CAPACITOR NCPE 418 4010 D 30ufd 370VAC NCPE 424 4010 D 35ufd 370VAC...

Страница 13: ...4 20 208 230 60 1 12 14 4 20 208 230 60 1 12 14 8 25 Volts Hertz Phase Min AWG Wire Min Cir Ampacity Max Fuse COMPRESSOR 6 5 43 7 3 48 8 0 43 9 1 58 3 10 0 64 RLA Amps LRA Amps FAN MOTOR 0 25 1500 1 4...

Страница 14: ...08 230 60 1 12 14 4 20 208 230 60 1 12 14 4 20 208 230 60 1 12 14 8 25 Volts Hertz Phase Min AWG Wire Min Cir Ampacity Max Fuse COMPRESSOR 6 5 43 7 3 48 8 0 43 9 1 58 3 10 64 RLA Amps LRA Amps FAN MOT...

Страница 15: ...208 230 60 1 14 10 2 15 208 230 60 1 12 14 4 20 208 230 60 1 12 14 8 25 Volts Hertz Phase Min AWG Wire Min Cir Ampacity Max Fuse COMPRESSOR 6 5 43 7 3 48 9 1 58 3 10 0 64 RLA Amps LRA Amps FAN MOTOR...

Страница 16: ...P 1500 RPM 14 Prop Fan Motor Mount Access Panel 1000 Top Panel 1000 Right Side Panel Left Side Panel Wire Grille 1000 Radial Fan Mount Touch Up Paint 14208360 14270049 14214033 14270102 14256318 14256...

Страница 17: ...Access Panel 1000 Top Panel 1000 Right Side Panel Left Side Panel Wire Grille 1000 Radial Fan Mount Touch Up Paint 14208361 14270049 14214033 14270102 14256318 14256316 14256315 14256343 14256001A 142...

Страница 18: ...8 9 10 11 12 13 14 15 16 17 18 Outdoor Coil Motor 0 25 HP 1500 RPM 14 Prop Fan Motor Mount Access Panel 3000 Top Panel 3000 Right Side Panel Left Side Panel Wire Grille 3000 Radial Fan Mount Touch Up...

Страница 19: ...Mount Access Panel 3000 Top Panel 3000 14208356 14270049 14214033 14270102 14256305 14256303 14208357 14270049 14214033 14270102 14256305 14256303 14208357 14270049 14214033 14270102 14256305 14256303...

Страница 20: ...23 Outdoor Coil Motor 0 25 HP DC DC Motor Control Blower Wheel 7 6 x 8 0 Blower Housing Inlet Ring 2 req d Motor Blower Mount Access Panel 4000 Top Panel 4000 Right Side Panel Left Side Panel Wire Gri...

Страница 21: ...h Up Paint 14208359 14270049 14214033 14256102 14256332 14256335 14256338 14256337 14269004A 14256339 14299630 14208358 14270049 14214033 14256102 14256332 14256335 14256338 114256337 14269004A 142563...

Страница 22: ...22...

Страница 23: ...equire that defective parts be returned to verify and identify the cause of the defect LIMITATION OF WARRANTIES ALL IMPLIED WARRANTIES INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY ARE HEREBY LIMITE...

Страница 24: ...24...

Страница 25: ...a replacement compressor to be shipped from Bensalem PA The situation may present itself where it is better for the compressor to be returned to National Comfort Products during the 20 month Bristol w...

Страница 26: ...26...

Страница 27: ...eamless rifled copper tubes CABINET Unit cabinet shall be constructed of heavy gauge galvanized or aluminized steel The steel shall be treated by phosphate washes prior to electrostatically applied an...

Страница 28: ...NCPD E Split System Condensing Unit Installation Instructions Rev 08 11 2014...

Отзывы: