NATI Speedway 52619 Скачать руководство пользователя страница 9

9

Important Operating Instructions

DUTY CYCLE

Guard against electrical shock. Avoid body contact with grounded services such as pipes,
ovens, stoves, and refrigerator enclosures. If not properly grounded, this air compressor
can incur the potential hazard of light trickle shock, particularly when used in damp
locations. If electrical shock occurs, there is the potential of secondary hazard such your
hands contacting an operating air tool.

DUTY CYCLE

This air compressor pump is capable of running continuously. However, in order to
prolong the life of your air compressor, it is recommended that a 50% average duty cycle
be maintained. Duty cycle refers to the percentage of time a compressor can safely run
within a given amount of time expressed as a ratio. Example: Oil lubricated compressors
are typically rate at a 50% duty cycle, meaning that the compressor motor can run about
50% of the total time it is being used to supply air to a tool. During the ON time, the motor
is running to pressurize the tank. During the OFF time, the motor is stopped and the tools
are running off on the pressurized air stored in the tank. If your air tools are draining
pressure off of the tank too quickly, the compressor motor must run more than 50% of the
time the compressor is in use. This can lead to overheating and will significantly shorten
the life of the compressors.
This compressor is designed for household use only and is not intended for commercial
applications. It is well suited for do-it-yourselfers with a variety of automotive and home
uses.
This instruction manual is intended for your benefit. Please read and follow the safety,
maintenance, and troubleshooting steps described within to ensure your safety and
satisfaction. The contents of this instruction manual are based upon the latest product
information available at the time of publication. The manufacturer reserves the right to
make product changes at any time without notice.

WARNING: Read and understand this entire instruction manual before attempting
to assemble, install, operate, or maintain this air compressor. Failure to comply
with the instructions may result in serious personal injury and/or property damage.
SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.

Содержание Speedway 52619

Страница 1: ...88052619 01 2014 28 Gallon Air Compressor Model 52619 Actual product may vary slightly...

Страница 2: ...to avoid injuries and damage Please read the complete operating manual with due care Keep this manual in a safe place so that the information is available at all times If you give the equipment to an...

Страница 3: ...s ANSI Z28 1 specifications during air compressor operation Eyeglasses are not always safety glasses Be responsible for your hearing Wear hearing protection during extended periods of operation Use th...

Страница 4: ...when kept clean and in good working condition Keeping the air compressor clean dry and free of grime will add to its life and performance Childproof the workshop The use of master switches and padlock...

Страница 5: ...control tank pressure Never substitute parts or attempt to alter the factory set operating pressures Risk of burns Touching exposed metal such as the compressor head or exhaust tube can result in ser...

Страница 6: ...o be tilted from the normal position when operating The compressor must be run with the rubber feet resting on a flat and stable horizontal surface The air compressor must be used in a clean and well...

Страница 7: ...imilar to the adapter illustrated in Figure 1 B may be used to connect this plug to a 2 pole receptacle as shown in figure 1 B when a properly grounded outlet is not available The temporary adapter sh...

Страница 8: ...nt your product will draw Refer to the guide for minimum gauge required for extension cords Important Operating Instructions EXTENSION CORDS Use only extension cords that are intended for outdoor use...

Страница 9: ...g the OFF time the motor is stopped and the tools are running off on the pressurized air stored in the tank If your air tools are draining pressure off of the tank too quickly the compressor motor mus...

Страница 10: ...w the minimum preset pressure cut in pressure WARNING Do not leave the compressor unattended while the power switch is in the ON AUTO position 2 AIR TANK PRESSURE GAUGE The tank pressure gauge provide...

Страница 11: ...oad protector will shut off the motor Turn pressure switch to the OFF position and wait for unit to cool before pushing the reset button and restarting the compressor NOTICE This air compressor is des...

Страница 12: ...ain valve The air compressor will build air pressure to the maximum preset pressure cut out pressure and automatically shut off 9 Slowly turn the tank drain valve to open airflow from drain and bleed...

Страница 13: ...pressure gauge to ensure that it reads 0 PSI 4 Remove the air hose and any air accessories 5 Drain moisture from the air tank by slowly opening the air tank drain valve by turning counterclockwise Ti...

Страница 14: ...be replaced if it cannot be actuated or it leaks air after the ring is released 1 The air compressor must be turned OFF 2 Disconnect compressor from the power source 3 Open tank drain to bleed off al...

Страница 15: ...se compressed air to blow loose dirt and debris from the paper filter element Replace filter element if it cannot be cleaned sufficiently 7 Reinsert filter element into filter body and reinstall filte...

Страница 16: ...d length Wrong gauge wire or length of extension cord Symptom Possible Cause s Corrective Action The compressor does not start or restart Power cord not plugged in Plug cord into grounded outlet Motor...

Страница 17: ...le Cause s Symptom Remove clean or replace Defective pilot valve the check valve is stuck open Air continues to leak at motor pressure switch release valve after motor stops Limit the air pressure to...

Страница 18: ...to all fittings and connections Bubbles will appear at leakage points Tighten or replace leaking fittings or connections as needed Air leaks Replace with larger hose or connectors Hose or hose connect...

Страница 19: ...s or alterations or a lack of maintenance This product is intended for personal use The warranty will be voided if used in commercial rental or industrial applications NATI shall in no event be liable...

Страница 20: ...20 PARTS LIST 28 Gallon Air Compressor Model 52619 88052619 01 2014...

Страница 21: ...21 PARTS LIST 28 Gallon Air Compressor Model 52619 88052619 01 2014...

Страница 22: ...50 2 Capacitor 49 1 Stator 48 1 Dentiform Washer 47 1 Nut 46 1 Cylinder 45 1 Crankcase 44 1 Crank Shaft 43 1 Bolt M5 42 1 Spring Washer 41 1 Connect Rod 40 1 Bearing 39 1 Fan 38 1 Washer 37 1 Spring W...

Отзывы: