16
KEYBOARD FAULT
A keyboard button has been
pressed for more than 120 seconds
Check that the push-button panel is not accidentally
pressed
Call the assistance service
GENERAT. TIMEOUT
Failure to detect AC power within
30 seconds of starting the
generator.
Check the generator start signal wiring.
Check the AC power supply wiring.
Check the correct functioning of the generator.
INV SUPPLY:OFF
Deactivation of both AC and DC
contactors following the
simultaneous pressing of both the
AC and DC buttons.
Select a power source using the corresponding
button.
INV SUPPLY: DC
Closing the DC contactor
INV SUPPLY: AC
Closing the AC contactor
AC Wait
Waiting for the AC power supply
(generator) following a request.
DC Wait
Waiting for the DC supply to
stabilize for 5 minutes before
attempting to switch to DC.
Charging Battery
Battery charging in progress.
Low PV Energy
Insufficient energy to switch to DC.
Daily Flow OK
Daily flow rate reached.