background image

www.nassarelectronics.com

3

PM-22 PUMP MONITOR MANUAL

Supply Voltage Selection

When the Pump-Monitor is turned ON for the first time 
it  will  ask  the  user  to  input  if  the  supply  voltage  is 
220VAC or 120VAC. This selection is done to calibrate 
the voltage readings.

Once the  supply  voltage  is  selected it  won’t  ask  the 
user  again  for  this  setup.  If  the  supply  voltage 
configuration needs to be changed, power off the PM-
22  by  removing  the  supply  voltage.  Then  keep  the 
Reset  button  pressed  while  you  turn  ON  the  PM-22 
again.  If  done  correctly  the  PM-22  will  ask  for  the 
supply voltage again.

SELECT:
220 V  PRESS RESET

Before the PM-22 unit is ready to be used it MUST BE 
CALIBRATED. Calibration may be performed as many 
times as desired.

 

Important  Note:  Please  make  sure  the  PM-22  is 
calibrated during normal pumping conditions.

While  the  pump  is  operating    press  and  hold  both 
arrow buttons until LCD displays the calibration.

Automatic calibration

  UL=780  OL=1500

CAL.  P=1200 W

Setup

Reset

Last

Failure

CALIBRATION

AUTO CALIBRATION

  WAIT 5 SEC.

The  PM-22  measures  the  power  and  sets  the 
calibration  for  underload  (UL)  at  65%  of  the  power 
consumption and at 125% for overload (OL). These are 
the recommended values, but they can be manually 
adjusted later if desired. 

The calibration is permanently stored, it does not 
need to be recalibrated if power is lost. 

Verify  that  the  pump  is  running  normally  (i.e.  the 
system  is  pumping  water  and  the  motor  current  is 
normal). Try to achieve the maximum water flow rate. 
Calibration on a fully recovered well is recommended. 
The calibration may be repeated to assure that setup 
was done when the pump was running under normal 
conditions.

SET: RESET DELAY

 60 Min.

SET RESET:

 MANUAL

SET:UNDER LOAD

 UL=2312 W

Setup

Press the SETUP button to select between manual or 
automatic reset. Press the downwards arrow button to 
choose MANUAL reset or the upwards arrow button to 
choose AUTOMATIC reset.

RESET DELAY

Press  the  SETUP  button  again.  If  the  AUTOMATIC 
option is selected  the reset delay setup will be shown.
Press  the  up  or  down  arrow  buttons  to  adjust  the 
desired reset delay from 1 to 120 minutes.

UNDERLOAD

Proceed  by  pressing  again  the  SETUP  button,  the 
underload  trip  value  will  be  displayed.  This  setup 
allows  to  modify  the  underload  protection  if  the 
a u t o m a t i c   c a l i b r a t i o n   a d j u s t m e n t   w a s   n o t  
appropriate. The  PM-22  will  disconnect  the  pump  if 
the power is below the selected value.

Use the arrow buttons to set up the desired value in 
10W increments. If the button is kept pressed it will 
move by 100W  increments.

OVERLOAD

When pressing the SETUP button the overload setup is 
displayed.  This  setup  allows  to  modify  the  overload 
protection  if  the  automatic  calibration  adjustment 
was not   appropriate. The PM-22 will disconnect the 
pump if the power is above the selected value.

SET:OVER LOAD

 OL=3451 W

PM-22 PUMP MONITOR MANUAL ENGLISH 2018

viernes, 4 de octubre de 2019 10:45:09 a. m.

Содержание PM-22

Страница 1: ...INCE 1973 PUMP MONITOR MODEL PM 22 www nassarelectronics com The best solutions for automation and protection User Manual PM 22 PUMP MONITOR MANUAL ENGLISH 2018 viernes 4 de octubre de 2019 10 45 06 a m ...

Страница 2: ...osureshouldbeused The PM 22 must be protected by a fuse or circuit breaker to avoid any damage The following diagrams show how to connect the PM 22 depending on the supplyvoltageavailable 120VACSUPPLYVOLTAGE Features Ÿ Protects pumps from dry well dead head jammed impeller waterlogged tanks rapid cycling under over voltage and over underload Ÿ Starts motors up to 1 5 HP without the need of an exte...

Страница 3: ...rify that the pump is running normally i e the system is pumping water and the motor current is normal Try to achieve the maximum water flow rate Calibration on a fully recovered well is recommended The calibration may be repeated to assure that setup was done when the pump was running under normal conditions SET RESET DELAY 60 Min SET RESET MANUAL SET UNDER LOAD UL 2312 W Setup Press the SETUP bu...

Страница 4: ...reen This is useful when the system presents considerable load variation and the automatic calibrationvaluesneedtobeadjusted AUTOMATICRESET After a failure has occured except under over voltage the PM 22 will start to count down the time set on the restart delay if the automatic reset is enabled The pump will restart when the timer finishes RESET DELAY 6 MIN LEFT The display shows the time left to...

Страница 5: ...howninthegraphicbelow 100 125 150 175 200 225 250 275 5 10 15 20 25 OVERLOAD TRIP DELAY Sec OVER LOAD TRIP DELAY The overload trip point is set to 125 of the power consumption during automatic calibration but it can alsobe adjustedmanually UNDERVOLTAGEPROTECTION The PM 22 protects the motor if the voltage drops from normal conditions It shuts down the motor after a 5 s trip delay The under voltage...

Страница 6: ...justmentseasier Ifthisunit ispanelmounted thepanelneedstobeinstalledindoors Din rail mounting Mounting hole Mounting hole Mounting options Dimensions This unit can be mounted on a standard 35 mm DIN rail or screwed into a surface using the screws included in the package Enclousure Dimensions 5 7 x 4 1 x 2 4 in PM 22 PUMP MONITOR MANUAL PM 22 PUMP MONITOR MANUAL ENGLISH 2018 viernes 4 de octubre de...

Страница 7: ... by this limited warranty and shall be at the buyer s expense All costs of dismantling reinstallationandfreight andthetimeandexpensesshallbebornebythebuyer LIMITATIONOFREMEDYANDLIABILITY NASSAR ELECTRONICS SHALL NOT BE LIABLE FOR DAMAGES CAUSED BY DELAY IN PERFORMANCE THE REMEDIES OFTHE BUYER SET FORTH IN THIS AGREEMENT ARE EXCLUSIVE IN NO EVENT REGARDLESS OF THE FORM OF THE CLAIM OR CAUSE OF ACTI...

Отзывы: