List of Components

3

LIST OF COMPONENTS FOR LF01274

•  2-oz. bottle of Baby powder 

•  2-oz bottle of lubricant

•  Replacement Skin, Light

LIST OF COMPONENTS FOR LF01275

•  2-oz. bottle of Baby powder 

•  2-oz bottle of lubricant 

•  Replacement Skin, Medium

LIST OF COMPONENTS FOR LF01276

•  2-oz. bottle of Baby powder 

•  2-oz bottle of lubricant 

•  Replacement Skin, Dark

LIST OF COMPONENTS FOR LF01277

•  2-oz. bottle of Baby powder 

•  2-oz bottle of lubricant 

•  Replacement Skin, Medium

•  8 Tubing Adapters

•  4 Dry Natural Rubber Tubes (Veins)

Содержание LF01274 Light

Страница 1: ...Skin and Vein Replacement LF01274 Light LF01275 Medium LF01276 Dark LF01277 Veins INSTRUCTION MANUAL WARNING Products may contain dry natural rubber Do not remove film from tubing ...

Страница 2: ...2 ...

Страница 3: ...OR LF01275 2 oz bottle of Baby powder 2 oz bottle of lubricant Replacement Skin Medium LIST OF COMPONENTS FOR LF01276 2 oz bottle of Baby powder 2 oz bottle of lubricant Replacement Skin Dark LIST OF COMPONENTS FOR LF01277 2 oz bottle of Baby powder 2 oz bottle of lubricant Replacement Skin Medium 8 Tubing Adapters 4 Dry Natural Rubber Tubes Veins ...

Страница 4: ...s and discard If replacing only the veins pull the skin down only far enough to expose the veins without removing the skin completely from the fingers This will make it easier to pull the skin back on when finished C Remove the foam shoulder injection pad See figure 2 D Remove the bicep muscle located over the manifold E Remove the old veins from the grooves unplug them from the manifold and disca...

Страница 5: ...ons shown on the diagram Veins may be trimmed with scissors for a good fit just make sure that the connector block is back in its cor rect location within the core and that the tubing is not kinked pinched or too tightly stretched Slight pinching in the finger area is normal and will not obstruct blood flow A Figure 3 shows how the four vein tubing sections should be connected to the connector blo...

Страница 6: ...he same channel Pass the tubing over the first section of green tubing and under the second section refer to diagram above The couplers should be approximately in the positions shown in the diagram Connect the tubing to fitting 5 trimming excess C Refer to Figure 5 Green Plug one end of a uniform diameter tubing piece into fitting 2 Press the tubing into the channel around the loop near the wrist ...

Страница 7: ... care to minimize pinching in the loops around the two fingers and the back of the hand Run the tubing under the red tubing and over both lengths of yellow tubing before connecting to fitting 8 trimming excess F Double check that all the tubing is in the correct channel and free of kinks or other obstructions Check that all fitting connections are as tight as possible to prevent leaks ...

Страница 8: ... finger section to the core fingers see Figure 9 Caution work the skin on gently NOTE Plastic wrap is occasionally used during the manufacturing process to keep the veins in place Plastic wrap can be used prior to sliding the skin into place to assist in keeping the veins in place during this process D Guide the fingers and thumb carefully into the proper holes Mistakes can be corrected by sliding...

Страница 9: ...orrectly seated Tubing that has moved can usually be moved back into position by working on the outside of the skin See figure 11 Figure 11 Figure 12 Figure 13 G Feed the inlet outlet tubing through the skin to the outside H Adjust the end flap over the top of the arm ...

Страница 10: ...ection Pad Replacement LF00993U Replacement Vein Manifold LF00985U Lubricant pack of 6 2 oz bottles LF01279U Skin Sealant LF01022U Fluid Supply Stand LF01099U Vein Tubing Sealant LF01104U Life form IV Arm Skin Vein Replacement DVD FREE LF01105U Life form IV Arm Set Up Troubleshooting DVD FREE LF01274 Light Skin Replacement Kit LF01275 Medium Skin Replacement Kit LF01276 Dark Skin Replacement Kit L...

Страница 11: ...nfusion LF01121U Advanced IV Arm LF01131U Venipuncture and Injection Arm LF01139U Advanced IV Hand LF01162U Venatech IV Trainer LF01184U Venatech IM Sub Q LF03616U Complete Child CRiSis Manikin LF03617U Deluxe Child CRiSis Manikin with Arrhythmia Tutor LF03620U PALS Update Kit LF03632U Child Intraosseous Infusion Femoral Access Leg on a Stand LF03636U Infant IV Leg LF03637U Infant IV Arm LF03709U ...

Страница 12: ...asco Healthcare 16 Simulaids Drive Saugerties NY 12477 1 833 NASCOHC 627 2642 info nascohealthcare com www nascohealthcare com NC 307633 IM 601004 05 20 2020 Nasco Healthcare FORMERLY SIMULAIDS LIFEFORM ...