INTELLIREAM
®
MP
pg.
41
B.2 Wire Cutter Replacement
•
Disconnect air and electrical supply.
• Unfasten (4) #8-32 button head cap screws, item 1.
(9/64
” hex drive)
• Remove wire cutter guard, item 2.
• Remove wire cutter module, item 3.
• Insert new wire cutter module. NOTE: The cutters
will close slightly when positioning the rollers against
the wedge.
• Replace wire cutter guard, item 2.
• Fasten (4) #8-32 button head cap screws, item 1.
Apply medium strength thread-locker.
(9/64
” hex drive)
• Reconnect air and electrical supply
B.3 Wire Cutter Troubleshooting
Additional troubleshooting information can be found in the Troubleshooting Section 7. As the wire cutter uses
the same electrical and pneumatic signals as the clamp, check the troubleshooting instructions for the clamp.
Problem
Possible Cause
Solution
Wire cutter won’t cut wire
but the cutter closes
-Insufficient air supply
-Cutters are worn or
damaged
-Wire diameter too large
-Set to 80 PSI
-Replace damaged components
-Check wire diameter
1
2
3