background image

7. OVERHEAT PROTECTION

- Once the temperature of the stone housing exceeds 320 degrees, a separate overheat  
  protection circuit cuts the power feed to the heating elements. As a result, the following  
  text will be displayed on the screen: Er3
- The overheat protection circuit is in the connection casing of the heater
- The overheat protection circuit can be mechanically reset by pressing the return button
- Once the heater has cooled down to under 280 degrees, the overheat protection can be  
 restored
- Overheat protection can only be reset by a person who is certified to do electrical work.
- Electricity supply to the heater must be switched off from the fuse panel before any  
  service measures. 
- Turn the mains switch to the 0 position
- The return button is pressed with enough force to hear a click (see image 2)
- Turn the mains switch to the power-on position 

8. PLACEMENT OF SAUNA HEATER STONES

- The electric sauna heater stones must be specific heavy and large 10-15 cm
  diameter cut-off stones intended for heat-retentive sauna heaters
- The use of ceramic, lightweight, or stones with few edges or of even sizes are not 
  allowed.  These may cause poor air circulation in the stone housing. 
  Soft soapstones cannot be used as heater stones
- The stones should be rinsed with water prior to being placed in the heater
- When positioning the stones, care must be exercised to prevent the heating elements 
  from bending or limiting air circulation
- Position the stones scarcely. If the stone housing is loaded too full, sufficient air
  circulation will be prevented
- The stone housing must be completely filled, while ensuring that the cover can
  properly close
- The heater stones should be inspected and repositioned every 6 months and the stones
  should be replaced every 2-3 years
- The heater cannot be heated without the stones in place
- Initial heating of the stove must be completed twice (heat for one hour using full power).

9. HEATING THE SAUNA ROOM FOR USE

- The heater stones are ready to use for bathing due to the initial heating, but raising
  the temperature of the sauna room to a pleasant temperature will require some 
  additional time
- The heater is set to full power, the cover is opened and 5-15 minutes later the sauna
  has reached a pleasant temperature
- Water can be thrown on the heater stones to increase the temperature in the sauna
  prior to bathing

6. THERMOSTAT

-   The heater temperature is monitored by a thermostat
-   Measuring the temperature is implemented using a heat-monitoring temperature sensor
-   The thermostat will maintain the precise temperature in the stone housing of the
  heater, even if the heater cover would be closed and the heater would be on full
  power, the thermostat will prevent an excessive rise in temperature

Содержание STEAM READY 905005

Страница 1: ...NARVI STEAM READY FI SE GB DE RU ASENNUS JA K YTT OHJE INSTALLATIONS OCH BRUKSANVISNING INSTALLATION AND INSTRUCTION MANUAL INSTALLATIONS UND BETRIEBSANLEITUNG VERSIO 03 2014...

Страница 2: ...a ei tarvita muuta l mmityst saunan kuivana pit miseen Kiuasmalli Teho Muhimisteho L ylyhuone Kivim r Liit nt Tilavuus Korkeus 400 V 3N Sulakkeet min max min kW W m3 m3 cm kg mm2 A 905005 6 650 5 9 19...

Страница 3: ...l n kyy kivitilan l mp tila Muhimisl mp tilan s d t napeilla kun ko toiminto on p ll Pitk painallus 1 sekunti ohjausyksikk kiuas pois p lt 5 T YSTEHO P LLE T ysteho saadaan painamalla toiminton pp int...

Страница 4: ...ukaan kivet on syyt huuhdella ennen kiukaaseen laittoa Kivien ladonnassa on huolehdittava etteiv t vastukset taivu eik riitt v ilmankierto esty Lado kivet harvaan Liian tiiviiksi t ytetty kivitila est...

Страница 5: ...astunut Tarkista kivien kunto Ovatko kivet laskeutuneet liian tiiviiksi 12 SAUNAHUONE S hk l mmitteisess saunassa kaikki massiiviset sein pinnat jotka varaavat l mp pit isi erist riitt v sti N in saad...

Страница 6: ...a kiinnitet n vastakkaisista kulmista lattiaan Kiukaan voi asentaa suoraan puulattian p lle min 700 max 500 min 20 min 100 min 100 max 900 min 200 P virtakytkin Kuva 4 Kiukaan asennuksessa on huomioit...

Страница 7: ...Kytkent rasian on oltava roiskeveden pit v ja sen korkeus lattiasta korkeintaan 50 cm Tarkempia asennukseen liittyvi ohjeita saa paikalliselta s hk viranomaiselta ks kytkent kaavio kuva 7 Kuva 7...

Страница 8: ...h vs n gon annan form av v rmek lla i bastun 2 TEKNISK INFORMATION Bastuugnsmodell Effekt Varmh llnings Basturum Stenm ngd Anslutning effekt Anslutning H jd 400 V 3N S kringar min max min kW W m3 m3 c...

Страница 9: ...armh llningseffekten inst lls med knapparna d denna funktion r p kopplad En l ng tryckning p knappen 1 sekund bryter str mmen till styrenheten bastuaggregatet 5 INKOPPLING AV FULL EFFEKT Funktionen Fu...

Страница 10: ...och skador p elementen p grund av d lig luftcirkulation Anv nd inte heller mjuk t ljsten som bastusten Stenarna b r tv ttas innan de staplas i stenmagasinet Se till att v rmeelementen inte b js och a...

Страница 11: ...ull effekt Basturummet v rms upp onormalt l ngsamt Kontrollera stenarnas skick Har stenarna sjunkit ned och packats samman 12 BASTURUMMET I en eluppv rmd bastu b r alla massiva v ggytor som lagrar v r...

Страница 12: ...ceras fritt p golvet och monteras s att motst ende h rn f sts i underlaget Aggregatet kan placeras direkt p tr golv Aggregatet b r riktas s att dess lock som f ngar upp det kastade vattnet styr den up...

Страница 13: ...N rmare anvisningar f r montering ges av de lokala elmyndigheterna se kopplingsschema bild 7 Bild 7...

Страница 14: ...heating is needed to keep the sauna dry 2 TECHNICAL SPECIFICATIONS Model Power Heat retention Steam room Stone volume Connection function Volume Height 400 V 3N Fuses min max min kW W m3 m3 cm kg mm2...

Страница 15: ...The display will show the stone housing s temperature The standby temperature is adjusted using the keys when the function in question is on Long press 1 second control unit heater turned off 5 TURNI...

Страница 16: ...water prior to being placed in the heater When positioning the stones care must be exercised to prevent the heating elements from bending or limiting air circulation Position the stones scarcely If th...

Страница 17: ...minated engage full power The temperature increase in the sauna room is slower Inspect the stones Have the stones settled too tightly 12 SAUNA ROOM In an electric sauna all wall surfaces that retain h...

Страница 18: ...he opposite corners to the floor The heater can be installed directly onto a wooden floor The direction of the water being thrown must be taken into consideration when installing the heater as the cov...

Страница 19: ...oupling box must be water resistant and its height from the floor should be a maximum of 50 cm More detailed instructions are available from the local electrical authority see wiring diagram image 7 I...

Страница 20: ...t der Saunaraum keine andere W rmequelle um die Sauna trocken zu halten 2 TECHNISCHE DATEN Saunamodell Leistung Stand by Leistung Saunaraum Steinmenge Anschluss Rauminhalt H he 400 V 3N Sicherungen mi...

Страница 21: ...er wird angezeigt Die Stand by Temperatur wird mit den Tasten ver ndert wenn diese Funktion aktiviert ist Langes Dr cken 1 Sekunde schaltet die Steuereinheit und den Saunaofen aus 5 ZUSCHALTEN DER VOL...

Страница 22: ...ine sollten vor dem Einschichten in den Saunaofen abgesp lt werden Beim Stapeln der Steine muss daf r gesorgt werden dass die Heizwiderst nde nicht verbogen werden und die Luftzirkulation nicht behind...

Страница 23: ...ine zu dicht abgesetzt 12 SAUNARAUM In einer elektrisch beheizten Sauna m ssen alle massiven Wandfl chen die W rme speichern aufreichend isoliert werden So wird die Leistung des Saunaofens angemessen...

Страница 24: ...nur ein saunaofen installiert werden Wenn das Haus elektrisch geheizt wird kann dann die Heizung niedriger eingestellt werden Sicherungen und Anschlusskabel entsprechend den Vorschriften Der Saunaofen...

Страница 25: ...nschlussdose muss spritzwasserfest sein und der Abstand vom Boden h chstens 50 cm betragen Genauere Anweisungen f r das Anklemmen erhalten Sie vom lokalen Versorgungsunternehmen Siehe Schaltplan in Ab...

Страница 26: ...Leistung Stand by Leistung Saunaraum Anschluss Rauminhalt H he 400 V 3N Sicherungen min max min kW W m3 m3 cm kg mm2 A 905005 6 650 5 9 190 80 5x1 5 3x10 905006 9 1000 9 14 190 80 5x2 5 3x16 Anschluss...

Страница 27: ...3 90 20 1 2 3 5 x 15 2 4 I O 3 150 220 5 1 5 min 700 max 500 min 20 min 100 min 100 max 900 min 200 min 30 1 2 3 4 5 6 1 2 3 4 5 6 1 3 2...

Страница 28: ...7 320 Er3 280 2 8 10 15 1 2 2 3 9 5 15 6...

Страница 29: ...10 11 12 1 5 3 1 5 13 500 50 100 100 150...

Страница 30: ...0 4 5 6 min 700 max 500 min 20 min 100 min 100 max 900 min 200 P virtakytkin min 50 min 20 min 50 min 20 m min 100 505 max 900 min 200 P virtakytkin max 700 min 50 min 20 min 50 min 20 min 50 min 20 m...

Страница 31: ...7 50 7...

Страница 32: ...Narvi Oy Yritt j ntie 14 27230 Lappi Finland Tel 358 207 416 740 www narvi fi Narvi Oy pid tt oikeudet tuotteisiin tuleviin muutoksiin 03 2014...

Отзывы: