INSTALLATION AND OPERATING
INSTRUCTIONS
NARVI NM
4,5kW
6kW
9kW
NARVI MINEX 2,3kW
3kW
3,6kW
GB
Please read the manual carefully before you start installing and using it and
keep the manual for future reference. The products are meant only to be
used as a sauna heater and for heating the sauna.
1. THE ELECTRICAL SAUNA STOVE PACKAGE INCLUDES:
1. Sauna stove jacket
2. Stone basket with control device
3. Mounting plate + anchor screws
4. Installation instructions and instructions how to use
2. BEFORE INSTALLATION:
Check the following:
- The sauna stove is the right size (kW) for the size of the sauna (cu m).
- Table 1 shows the volumes of the sauna for the different types of stoves.
- If the sauna has non-insulated surfaces, for instance brick, tile or glass,
1.5 cu m must be added to the sauna volume for each square metre of
wall on the basis of which the effect needed for the sauna stove is
defined according to Table 1.
The volume values of the sauna according to Table 1 must not be
exceeded or lowered.
- The minimum height of the sauna and the distances of the minimum
protected areas have been defined in Table 1.
- Make sure that there is a sufficiently steady mounting plate for the
anchor screws. A thin panel alone is not enough. Additional supporting
rails behind the panel or reinforcement boards on the top of the panel
which are fastened to the wall support can be a reinforcement.
TECHNICAL DATA
NM
MINEX
- Width
430 mm
330 mm
- Depth
300 mm
200 mm
- Height
580 mm
630 mm
- Weight
(without stones)
10 kg
7 kg
Heater
model
Capacity
Sauna room
Minimal safety clearances to the heater
Quantity
of stones
Connection *)
Connection *)
Volume
Height
on the
sides
at the
front
at the
front
to the
ceiling
to the
floor
5-10
cm
400 V 3N~ Fuses 230 V 1N~
Fuses
min max
min
A **)
B **)
C **)
D **)
E **)
kW
m
3
m
3
mm
mm
mm
mm
mm
mm
kg
mm
2
A
mm
2
A
NM
4,5
3
6
1900
50
50
20
1150
120
30
5x1,5
3x10
-
-
6
5
8
1900
50
80
20
1150
120
30
5x1,5
3x10
-
-
9
8
14
1900
100
100
20
1150
120
30
5x2,5
3x16
-
-
MINEX
2,3
1,5 2,5
1900
20
50
20
900
150
15
-
-
3x1,5
1x10
3
2
3
1900
20
50
20
900
150
15
-
-
3x2,5
1x16
3,6
2
4
1900
20
50
20
900
150
15
-
-
3x2,5
1x16
Table 1. Installation information for heater
**) See figure 1
*) Connected with rubber cable, type H07RN-F
or corresponding cable
Figure 1. Minimal safety clearances
for the heater.
B
min. 20
min. 20
A
NM:
C
E
D
MINEX:
B
C
A
E
D