3. Installation and 

preheating of the sauna 

heater

3.1 Preheating

Before  use  and  arranging  the  stones,  the  sauna  heater 
must be heated to remove the protective agents. Any pro-
tective films and stickers must have been removed before. 

Preheating shall be carried out on a non-combustible 
surface and outside

, since paint emits harmful solvents 

and  smoke  during  heating.  Use  of  a  connection  pipe  in-
cluded in the delivery of the sauna heater in the upper joint 
improves  draft  during  preheating.  1-2  fireboxes  of  wood 
are  sufficient  for  preheating.  After  preheating  and  before 
arranging  the  stones  loose  cover  material  should  be  re-
moved  from  the  stone  compartment  of  the  sauna  heater 
with a steel brush. In case the external surface of the sauna 
heater is painted, it should not be rubbed or wiped before 
the first heating. The paint of the sauna heater will achieve 
sufficient strength only after the first heating. Do not create 
steam during the first heating.

NB!  If  the  sauna  heater  is  equipped  with  a  water  tank 
please check before preheating that the water tank faucet 
and  safety  plug  are  installed  and  that 

the tank is filled 

with clean water.

3.2 Regulation of the height

The  legs  of  the  sauna  heater  are  adjustable  and  can  be 
used  for  levelling  the  sauna  heater  and  for  adjusting  the 
height. There must be an air gap of at least 25 mm between 
the sauna heater and the floor. Use a spirit level to check if 
the sauna heater is level.

3.3 Connection with the stack

The sauna heater can be connected to the smoke flue from 
the top or back of the sauna heater. Seal the unused open-
ing with the supplied cover. The sauna heater comes with 
a short smoke flue connection pipe, which can be used to 
connect the sauna heater’s smoke flue from the back. If the 
connection with the smoke flue is done from the above, a 
Kota connective flue or Kota smoke flue must be used. In 
case of connection from the above, a Kota smoke flue tank 
for heating water or a Kota stone basket can be installed 
around the connective flue.

Do not push the connective flue too deep in the smoke flue, 
because this would hinder the draft. Any leaks in the con-
nective flue also reduce the draft; therefore the connections 
must be sealed with fireproof sealing material. 

Leakage in 

the connective flue causes combustion gases formed 
in the sauna heater to ignite in the flue.

 The connection 

joint of the flue and the sauna heater must be 25 mm. The 
diameter of the connective flue of the sauna heater and the 
height from the floor are shown in clause 

1.1.

Please  take  into  account  the  clearance  distance  of  the 
modular smoke flue, see the manufacturer’s instructions.

3.4 Installation of a door and changing of the 

opening direction of the door

Figure 7. 

Open the door and raise the hinge pin up so it 

comes out of the bottom hinge barrel. Hold onto the door 
securely and turn the bottom part of the pin and turn the 
bottom end of the pin up enough (2) that you can pull the 
pin down (3) and the pin and door come apart. For instal-
lation proceed in reverse order. First push the upper edge 
of the door in its place and thereafter push the pin through 
the upper eyelet. Thereafter turn the door and pin in their 
places from below and let the pin into the bottom eyelet. 
The pin is correctly installed when the wider areas of the 
pin are facing down. In this case the pin cannot move away 
from its place. Door installation is easier when you use long 
flatnose pliers.

3.5 Installation of the faucet, models with a 

water tank

The water tank is on the side of the stove and it has a large 
opening for filling it. For the water volume, see clause 

1.1.

 

The faucet is installed when the sauna heater is installed.

Figure 8.

 Place the faucet so that the threads are visible on 

the inside of the tank. Place the faucet so that the threads 
are  visible  on  the  inside  of  the  tank.  Place  the  washer  on 

Figure 8.

Figure 7.

Содержание NC 16

Страница 1: ...GB Made by NARVI Oy Finland Narvi NC 16 20 20 VS 24 sauna heaters Installation user and maintenance instructions Version 1 0...

Страница 2: ...Yritt j ntie 14 FI 27230 Lappi tel 358 0207 416 740 fax 358 0207 416 743 www narvi fi en 2 GB...

Страница 3: ...ation of the height 7 3 3 Connection with the smoke flue 7 3 4 Installation of a door and changing of the opening direction of the door 7 3 5 Installation of a water tank faucet models with a water ta...

Страница 4: ...e sauna heater preferably on the lower part of the cover of the sauna heater Do not heat the sauna heater if you lack sufficient knowl edge if you are not allowed to use a sauna because of your health...

Страница 5: ...R UN DERFLOOR HEATING A Kota installation base must be installed under the sauna heater which will protect the floor moisture barrier and un derfloor heating pipes or cables from the thermal radiation...

Страница 6: ...When installing a modular smoke flue safety clearances stipulated in the in stallation manual of the smoke flue shall be followed The minimum recommended diameter of a modular smoke flue is 120 mm The...

Страница 7: ...ue is done from the above a Kota connective flue or Kota smoke flue must be used In case of connection from the above a Kota smoke flue tank for heating water or a Kota stone basket can be installed a...

Страница 8: ...es Before using the stones they must be washed to eliminate any impurities Bigger stones are placed in the bottom of the stone compartment and the rest are piled sparsely so that air can move freely b...

Страница 9: ...from above reduces pollution and ensures cleaner burning The power of the sauna heater can be regulated by the ash drawer If the ash drawer is closed the power of the sauna heater is at its lowest and...

Страница 10: ...n the stones of the sauna heater to dry the sauna room In the ignition phase the closing pan must be fully open Before you close the closing pan after heating check that there is no glowing coal in th...

Страница 11: ...se installation and maintenance meet the requirements stipulated in the instructions The warranty period starts form the moment that the goods are delivered to the end user The supplier is not liable...

Страница 12: ...t i e nominal space heating output Back Side Ceiling 150 mm 150 mm 1 250 mm Pass Pass NPD Pass Pass 0 07 Pass 70 12 Pa 16 kW 7 kg Pass Pass 387 C Narvi Oy 12 EN 15821 2010 Multi firing sauna stoves fi...