NARVI Oy Finland NC 16 Скачать руководство пользователя страница 1

GB

Made by

 

NARVI Oy Finland

Narvi NC 16, 20, 20 VS, 24 sauna heaters 

Installation, user and maintenance instructions

Version 1.0

Содержание NC 16

Страница 1: ...GB Made by NARVI Oy Finland Narvi NC 16 20 20 VS 24 sauna heaters Installation user and maintenance instructions Version 1 0...

Страница 2: ...Yritt j ntie 14 FI 27230 Lappi tel 358 0207 416 740 fax 358 0207 416 743 www narvi fi en 2 GB...

Страница 3: ...ation of the height 7 3 3 Connection with the smoke flue 7 3 4 Installation of a door and changing of the opening direction of the door 7 3 5 Installation of a water tank faucet models with a water ta...

Страница 4: ...e sauna heater preferably on the lower part of the cover of the sauna heater Do not heat the sauna heater if you lack sufficient knowl edge if you are not allowed to use a sauna because of your health...

Страница 5: ...R UN DERFLOOR HEATING A Kota installation base must be installed under the sauna heater which will protect the floor moisture barrier and un derfloor heating pipes or cables from the thermal radiation...

Страница 6: ...When installing a modular smoke flue safety clearances stipulated in the in stallation manual of the smoke flue shall be followed The minimum recommended diameter of a modular smoke flue is 120 mm The...

Страница 7: ...ue is done from the above a Kota connective flue or Kota smoke flue must be used In case of connection from the above a Kota smoke flue tank for heating water or a Kota stone basket can be installed a...

Страница 8: ...es Before using the stones they must be washed to eliminate any impurities Bigger stones are placed in the bottom of the stone compartment and the rest are piled sparsely so that air can move freely b...

Страница 9: ...from above reduces pollution and ensures cleaner burning The power of the sauna heater can be regulated by the ash drawer If the ash drawer is closed the power of the sauna heater is at its lowest and...

Страница 10: ...n the stones of the sauna heater to dry the sauna room In the ignition phase the closing pan must be fully open Before you close the closing pan after heating check that there is no glowing coal in th...

Страница 11: ...se installation and maintenance meet the requirements stipulated in the instructions The warranty period starts form the moment that the goods are delivered to the end user The supplier is not liable...

Страница 12: ...t i e nominal space heating output Back Side Ceiling 150 mm 150 mm 1 250 mm Pass Pass NPD Pass Pass 0 07 Pass 70 12 Pa 16 kW 7 kg Pass Pass 387 C Narvi Oy 12 EN 15821 2010 Multi firing sauna stoves fi...

Отзывы: