3-4
Operating Instruction
3.2.2 Short test mode
Setting test time
and open level
Wait five minutes between three short test cycles.
Using this test it is possible to do a short test with an high level of field, in
fact the maximum current is 1250 A for a maximum time of 5 seconds.
Pressing the SHRT key the display will be the following:
In the top of the display there is the indication of the level with reference to
the standard. The levels available are :
•
Level 4 300 A/m
•
Level 5 1000 A/m if antenna factor is
≥
0,87 otherwise is (1000/0.87)*K.
•
Level X open, in the range 300 - 1000 A/m (depending from antenna
factor)
Pressing the NEXT key it will be changed the level selected, and the
indication will appear in the top of the display.
Setting LEVX level
Pressing the SET key the display will show the following:
Using this menu it is possible to set the level of Level X and the time of the
test. Pressing LEVX the display will show the following