background image

25

W415-0689 / C / 06.13.12

SYMPTOM

PROBLEM

TEST SOLUTION

Burner will not light, 
ignitor sparks.

No gas at the burner.

 

-

Check that the manual valve is turned on.

 

-

Replace the valve.

Out of propane gas.

 

-

Fill the tank.

Ignitor will not spark.

No spark at ignitor.

 

-

Check the power source. (ie. fuse, circuit breaker)

 

-

Check that the wire is connected to both the ignitor 
and the control module.

 

-

Check that the spark is not jumping to ignitor cover.

 

-

Replace the wire if the wire insulation is broken or 
frayed.

 

-

Replace the electrode if the ceramic insulator is 
cracked or broken.

Spark gap is incorrect.

 

-

Spark gap should be 0.125” (1/8” approx.) from the 
electrode tip to the sensor tip.

Remote wall switch 
is in “OFF” position; 
burner comes on.

Wall switch is mounted 
upside down.

 

-

Reverse.

Remote wall switch is 
grounding.

 

-

Replace.

Remote wall switch 
wire is grounding.

 

-

Check for ground (short); repair ground or replace 
wire.

Faulty wire.

 

-

Replace.

CERAMIC
BODY

ELECTRODE

HIGH
VOLTAGE 
IGNITION
CABLE

1/8”

GAP

SENSOR

42.22_2

Содержание Torch GSST8N and

Страница 1: ...ther appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbou...

Страница 2: ...EARANCES TO COMBUSTIBLES 10 5 0 FINISHING 11 5 1 TMCSS MOUNTING CABINET INSTALLATION 11 5 2 RAIN TABS 12 5 3 DOOR REMOVAL 13 5 4 GLASS MEDIA INSTALLATION 14 5 5 TFSSO FRAME INSTALLATION 15 5 6 LOGO PL...

Страница 3: ...1 0 INSTALLATION OVERVIEW Cabinet see MOUNTING CABINET INSTALLATION section Door see DOOR REMOVAL section Glass see DOOR GLASS REPLACEMENT section Frame see FRAMING section Rating plate see RATING PLA...

Страница 4: ...keep toddlers young children and other at risk individuals away from hot surfaces Clothing or other ammable material should not be placed on or near the appliance Furniture or other objects must be k...

Страница 5: ...E WILL DAMAGE VALVE DISCONNECT GAS SUPPLY PIPING BEFORE PRESSURE TESTING GAS LINE AT TEST PRESSURES ABOVE 1 2 PSIG CLOSE THE MANUAL SHUT OFF VALVE BEFORE PRESSURE TESTING GAS LINE AT TEST PRESSURES EQ...

Страница 6: ...hearth products be installed and serviced by professionals who are certified in the U S by the National Fireplace Institute NFI as NFI Gas Specialists www nficertified org 2 3 GENERAL INFORMATION FOR...

Страница 7: ...E APPLIANCE MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS TOP 18 BACK 0 SIDES 1 FLOOR 8 SERIAL NUMBER ELECTRICAL RATING 115v 0 82AMP 60HZ TOP SIDES BACK AS PER ABOVE FOR FINISHING MATERIAL SEE OWNERS MA...

Страница 8: ...se etc G 3 FEET 3 FEET Clearance to each side of the centre line extended above the metre regulator assembly to a maximum vertical distance of 15 ft H 3 FEET 3 FEET Clearance to a service regulator ve...

Страница 9: ...AS CONNECTIONS MUST BE CONTAINED WITHIN THE APPLIANCE WHEN COMPLETE DO NOT USE OPEN FLAME This appliance is intended for installation on an outdoor patio or in your yard It must never be installed ins...

Страница 10: ...IN THE CABINET PROVIDED THE CABINET IS DESIGNED TO BE INSTALLED ON FINISHED SURFACES THE CABINET MAY BE INSTALLED DIRECTLY ONTO A COMBUSTIBLE SURFACE 4 0 FRAMING MINIMUM CLEARANCES TO COMBUSTIBLES 18...

Страница 11: ...4 hole centres on the wall surface using the template B Remove the template Depending on the surface and fasteners drill the appropriate holes Hold the Torch up aligning the mounting brackets to the m...

Страница 12: ...ners and slide the frame down onto the fasteners Ensure the frame is plumb and level before tightening the fasteners NOTE It is recommended that the gas and electrical be connected to the appliance at...

Страница 13: ...RN THE APPLIANCE OFF AND WAIT UNTIL APPLIANCE IS COOL TO THE TOUCH DOORS ARE HEAVY AND FRAGILE SO HANDLE WITH CARE 75 1 B O T TOM DOOR RETAINER T O P DOOR FLANGE SECURING THE DOOR IN PLACE When shippe...

Страница 14: ...tor CLEANING GLASS MEDIA Glass media may have a ne oil residue that needs to be cleaned prior to installation Clean the glass with mild dish soap drain rinse thoroughly and dry before placing around t...

Страница 15: ...e and the bottom hooks of the frame into the slot in the mounting cabinet B Install the trim bracket supplied in your manual baggie to the rebox using 3 screws NOTE If the frame needs to be secured us...

Страница 16: ...the frame E Connect the light assemblies to the appropriate ags on the wire harness The wire harness is labeled TR top right BR bottom right TL Top left and BL bottom left F Secure the wires into the...

Страница 17: ...or disconnecting any connectors it is highly recommended to re apply anti oxidant compound to the relative connections 6 0 ELECTRICAL INFORMATION WARNING RISK OF ELECTRIC SHOCK CONTROL AND VALVE OPER...

Страница 18: ...y to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If yo...

Страница 19: ...2 VENTURI ADJUSTMENT This model has an air shutter that has been factory set open according to the chart below Closing the air shutter will cause a more yellow ame but can lead to carboning Opening t...

Страница 20: ...he ame sensor and or thermocouple thermopile as well as reaches the burner E Replace the cleaned logs rocks or glass Failure to properly position the media may cause carboning which can be distributed...

Страница 21: ...discolour when heated usually to a golden or brown hue This discolouration is normal and does not affect the performance of the appliance 9 2 DOOR GLASS REPLACEMENT WARNING DO NOT USE SUBSTITUTE MATE...

Страница 22: ...RTY DAMAGE OR PERSONAL INJURY WARNING COMPONENTS REF NO PART NO DESCRIPTION 1 W225 0223 DOOR FRAME 2 W562 0008 DOOR GASKET 3 W010 1959 GLASS C W GASKET 4 W300 0110 GLASS 5 W100 0111 BURNER 6 W357 0006...

Страница 23: ...23 W415 0689 C 06 13 12 Items not shown to scale 1 3 5 6 7 11 12 14 22 21 10 18 20...

Страница 24: ...int or other obstructions Flame is impinging on the combustion chamber Open air shutter to increase the primary air Check the input rate check the manifold pressure and ori ce size as speci ed by the...

Страница 25: ...park is not jumping to ignitor cover Replace the wire if the wire insulation is broken or frayed Replace the electrode if the ceramic insulator is cracked or broken Spark gap is incorrect Spark gap sh...

Страница 26: ...es to appliance due to weather long periods of dampness condensation damaging chemicals or cleaners will not be the responsibility of NAPOLEON The bill of sale or copy will be required together with a...

Страница 27: ...27 W415 0689 C 06 13 12 13 0 SERVICE HISTORY 43 1...