Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleon.com
RIVERSIDE
™
36 CLEAN FACE OUTDOOR GAS FIREPLACE
Product information provided is not complete and is subject to change without notice. Please consult the installation manual for
the most up to date installation information.
W415-1914 / 12.17.18
Framing
Minimum Enclosure Clearances
46 9/16"
(118.2cm)
44”
(111.7cm)
20 1/2”
(52cm)
Steel Header
(Supplied)
Steel Header Installation
Type 1 (x3)
Type 2 (x3)
Type 3 (x3)
1.
Slide the 2 steel header pieces together, ensuring to align the 3 slots
(Fig. 1)
.
2.
Insert the 3 supplied bolts (Type 2) through the 3 slots
(Fig. 2)
.
3.
Secure the 3 nuts (Type 1) and the 3 washers (Type 3) to the back of the bolts
(Fig. 3)
.
Fig. 1
Fig. 2
Fig. 3
Reverse Side View
1” (25.4cm)
Top of combustible enclosure
50 3/4”
(128.9cm)
14 1/2”
(36.8cm)
Non-combustible
header (provided)
Non-Combustible Material
Top of
appliance
Combustible Material
Nailing strip
20 1/2” (52cm)
This appliance requires a minimum enclosure height of 50 3/4” (128.9cm).
For temperature requirements, the enclosure space around and above the
appliance must be left unobstructed.
Minimum Clearance to Combustible Enclosures