Problem
Possible Causes
Solution
Low heat / Low flame when
valve turned to high.
For propane - improper lighting
procedure.
Improper preheating.
Ensure lighting procedure is followed carefully.
All gas grill valves must be in the off position
when the tank valve is turned on. Turn tank
on slowly to allow pressure to equalize. See
lighting instructions.
Preheat grill with both main burners on high
for 10 to 15 minutes.
Excessive flare-ups/uneven
heat.
Sear plates installed incorrectly.
Improper preheating.
Excessive grease and ash build on
sear plates and in drip pan.
Ensure sear plates are installed with the holes
towards the front and the slots on the bottom.
See assembly instructions.
Preheat grill with both main burners on high
for 10 to 15 minutes.
Clean sear plates and drip pan regularly. Do
not line pan with aluminum foil. Refer to
cleaning instructions.
Burners burn with yellow
flame, accompanied by the
smell of gas.
Possible spider web or other
debris, or improper air shutter
adjustment.
Thoroughly clean burner by removing. See
general maintenance instructions. Open air
shutter slightly according to combustion air
adjustment instructions. (This must be done
by a qualified gas installer.)
Main burner will not light
with the igniter, but will light
with a match.
Jet-fire outlet is dirty or clogged.
Clean jet-fire outlet with a soft bristle brush.
Humming regulator.
Normal occurrence on hot days.
This is not a defect. It is caused by internal
vibrations in the regulator and does not affect
the performance or safety of the gas grill.
Humming regulators will not be replaced.
Burners will not cross light
each other.
Dirty or corroded cross light
brackets.
Clean or replace as required.
“Paint” appears to be peeling
inside lid or hood.
Grease build-up on inside
surfaces.
This is not a defect. The finish on the lid and
hood is porcelain, and will not peel. The
peeling is caused by hardened grease, which
dries into paint-like shards that flake off.
Regular cleaning will prevent this. See cleaning
instructions.
Burner output on “high”
setting is too low. (Rumbling
noise and fluttering blue
flame at burner surface.)
Lack of gas.
Supply hose is pinched.
Dirty or clogged orifice.
Spider webs or other matter in
venturi tube.
Propane regulator in “low flow”
state.
Check gas level in propane cylinder.
Reposition supply hose as necessary.
Clean burner orifice.
Clean out venturi tube.
Ensure lighting procedure is followed carefully.
All gas grill valves must be in the off position
when the tank valve is turned on. Turn tank
on slowly to allow pressure to equalize. See
lighting instructions.
Содержание PRO825
Страница 43: ...43 www napoleongrills com 1 2 3 4...
Страница 45: ...45 www napoleongrills com...
Страница 46: ...46 www napoleongrills com...
Страница 50: ...50 www napoleongrills com...
Страница 65: ...65 www napoleongrills com Notes...
Страница 66: ...66 www napoleongrills com Notes...
Страница 67: ...67 www napoleongrills com Notes...
Страница 68: ...N415 0306CE GB DE...