background image

6  

www.napoleonfireplaces.com

INSTALLATION

WARNING!

 When the appliance is being used with the optional tripod, it must not be situated on a 

combustible surface, nor can it be located below a combustible overhang.

The glass embers and the burner assembly are shipped together.

•  Remove the glass embers and burner assembly and check for damage. DO NOT install damaged components. 

The glass embers may have sharp edges, wear safety glasses and gloves when handling.

•  Place the appliance on a level/secure surface in desired location. This location must be adjacent to the 

gas supply line or cylinder. 

NOTE: Minimum clearances to combustible construction must be maintained, see "SPECIFICATIONS" section. 

WARNING!

 You must have clear and easy access to the on/off valve AFTER the appliance is installed 

and connected to the gas supply in order to safely turn off the burner.

THE ON/OFF GAS VALVE IS USED TO TURN THE BURNER ON AND OFF.

NATURAL GAS

Connect the incoming gas supply line to the on/off gas valve of the appliance. Make certain ALL gas connections are 

tight, turn the on/off valve at the unit slowly to the on position and use soapy water to test for leaks as indicated in 

the diagrams. 

DO NOT USE AN OPEN FLAME.

LP (PROPANE) GAS

Attach cylinder retaining bracket supplied to the base of the cylinder.  Then secure to the surface to which it 

sits. Cylinder should be on a level surface.
This appliance has been designed for use with a 20lb. (9.1kg) or a 30lb (13.6kg) size propane cylinder only 

(not supplied).

•  Make sure cylinder valve is in its full off position. (Turn clockwise to stop).

•  Check cylinder valve features to ensure it has proper external mating threads. (Cylinder Valve Marked: 

USE WITH TYPE 1)

•  Inspect hose shipped with the unit for damage. Never attempt to use damaged or plugged equipment. See 

your local LP Gas Dealer for repairs.

•  After inspecting the LP hose shipped with the unit, connect the end with the female fitting on the hose to 

the male fitting on the on/off gas valve at the end of the flex tube. Tighten fittings using 2 wrenches.

•  When connecting regulator assembly to the cylinder valve, hand tighten black QCC1 nut clockwise to a 

positive stop. DO NOT use a wrench to tighten. Use of a wrench may damage the quick closing coupling 

nut and result in a hazardous condition.

•  Locate the hose out of pathways where people may trip over it or in areas where the hose may be subject 

to accidental damage.

•  Open cylinder valve fully (counter-clockwise). Turn the on/off valve at the unit slowly to the on position 

and use a soapy water solution to check all connections for leaks  as indicated in the diagrams before 

attempting to light the appliance. If a leak is found, turn tank valve off and do not use the appliance until 

repairs can be made. 

Manual Gas 

Valve (on/off)

Burner Assembly

Manual Gas 

Valve (on/off)

Burner Assembly

Cylinder Retaining 

Bracket

DO NOT USE AN OPEN FLAME.

Содержание PATIOFLAME GPFGN and

Страница 1: ...NSTRUCTIONS CERTIFIED FOR CANADA AND UNITED STATES USING ANSI CSA METHODS Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas su...

Страница 2: ...t year only this warranty extends to the repair or replacement of warranted parts which are defective in material or workmanship provided that the product has been operated in accordance with the operation instructions and under normal conditions After the first year with respect to the President s Limited Lifetime Warranty NAPOLEON may at its discretion fully discharge all obligations with respec...

Страница 3: ...shall be used ONLY outdoors in a well ventilated space and shall NOT be used inside a building garage or any other enclosed area Cylinders must be stored outdoors in a well ventilated area out of reach of children Disconnected cylinders must have threaded valve plugs tightly installed and must not be stored in a building garage or any other enclosed area Storage of this appliance indoors is permis...

Страница 4: ...isconnected from the gas supply piping system during any pressure testing of the system at test pressures in excess of 1 2 psig 3 5kPa This appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5kPa The following clearances to combust...

Страница 5: ...MAX INPUT Btu Hr GPFN Natural Gas 60 000 GPFP Propane Gas 60 000 GAS INLET PRESSURES NATURAL PROPANE Minimum Inlet Pressure 4 5 w c 11 0 w c Maximum Inlet Pressure 14 0 w c 14 0 w c MINIMUM CLEARANCE TO COMBUSTIBLES INCHES MM Side Walls 24 610 Top of unit to ceiling 72 1830 ...

Страница 6: ...s Cylinder should be on a level surface This appliance has been designed for use with a 20lb 9 1kg or a 30lb 13 6kg size propane cylinder only not supplied Make sure cylinder valve is in its full off position Turn clockwise to stop Check cylinder valve features to ensure it has proper external mating threads Cylinder Valve Marked USE WITH TYPE 1 Inspect hose shipped with the unit for damage Never ...

Страница 7: ... the upper edge no more than 5 inches 127mm above the floor The openings shall be equally sized spaced at 180 degrees 3 14 rad and unobstructed c Every opening shall have minimum dimensions so as to permit the entrance of a 1 8 inch 3 2mm diameter rod Cylinder valves shall be readily accessible for hand operation A door on the enclosure to gain access to the cylinder valve is acceptable provided i...

Страница 8: ...ks Notched Rock GLASS MEDIA INSTALLATION WARNING Glass embers may have sharp edges wear safety glasses and gloves when handling Do not change or substitute the glass ember material provided with this fireplace If replacing use only replacement glass embers available from your local authorized dealer distributor 1 Carefully pour the appliance glass media onto the appliance log support as shown 2 Sp...

Страница 9: ...uch any electric switch Do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department LIGHTING INSTRUCTIONS 1 Locate the manual gas control valve 2 Place the firestarter near the burner ports on top of the burner Light the firestarter For a Natural Gas unit turn...

Страница 10: ...ing this appliance at an elevation above 4500 feet in the U S it may be necessary to decrease the input rating by changing the existing burner orifice to a smaller size Input should be reduced four percent 4 for each 1 000 feet beyond the 4 500 feet above sea level unless the heating value of the gas has been reduced in which case this general rule will not apply To identify the proper orifice siz...

Страница 11: ...D DEALER WARNING Failure to position the parts in accordance with this manual or failure to use only parts specifically approved with this appliance may result in property damage or personal injury COMPONENTS REF PART NO DESCRIPTION 1 QA 047 OUTER BASE 2 W655 0176 LOG SUPPORT 3 W010 1030 BURNER ASSEMBLY 4 W080 0618 ORIFICE BRACKET 5 W455 0076 PROPANE ORIFICE 43 W455 0077 NATURAL GAS ORIFICE 25 W45...

Страница 12: ...12 www napoleonfireplaces com 8 1 9 2 5 4 3 7 10 6 ...

Страница 13: ...13 www napoleonfireplaces com 43 1 SERVICE HISTORY ...

Страница 14: ...14 www napoleonfireplaces com 44 1 Notes ...

Страница 15: ...ucun interrupteur électrique n utilisez aucun téléphone dans votre immeuble Appelez immédiatement votre fournisseur de gaz d un téléphone voisin Suivez ses instructions Si vous ne pouvez pas rejoindre votre fournisseur de gaz appelez le service des incendies L installation et l entretien doivent être faits par un installateur qualifié une agence d entretien ou le fournisseur AVERTISSEMENT Si ces i...

Страница 16: ... excessive des produits d entretien chimiques et abrasifs le bris par manipulation des bûches et des braises Au cours de la première année seulement cette garantie s étend à la réparation ou au remplacement des pièces garanties dont les matériaux ou la fabrication sont défectueux sous condition que le produit ait été utilisé conformément aux instructions de fonctionnement et dans des conditions no...

Страница 17: ...nctionner avec un combustible solide Une installation non conforme des ajustements des altérations un service ou un entretien inadéquats peuvent causer des dommages matériels ou des blessures corporelles Lisez attentivement toutes les instructions d installation d opération et d entretien avant d installer ou d effectuer un travail d entretien sur cet appareil Cet appareil doit être utilisé UNIQUE...

Страница 18: ... les pressions d essai excèdent 1 2 lb po2 3 5 kPa L appareil doit être séparé de la ligne d alimentation en gaz en fermant la soupape de sectionnement ma nuelle pendant tout essai de pression du système d alimentation en gaz lorsque la pression est de 1 2 lb po2 3 5 kPa ou moins Les dégagements aux matériaux combustibles ci dessous doivent être maintenus Côtés tout autour 24 pouces 610 mm Dessus ...

Страница 19: ...ATIOFLAME SAILLIE MAX DÉBIT MODÈLE COMBUSTIBLE DÉBIT MAX Btu h GPFN Gaz naturel 60 000 GPFP Propane 60 000 PRESSIONS D ALIMENTATION EN GAZ NATUREL PROPANE Pression d alimentation minimale 4 5 c e 11 0 c e Pression d alimentation maximale 14 0 c e 14 0 c e DÉGAGEMENTS MINIMAUX AUX MATÉRIAUX COMBUSTIBLES POUCES MM Murs latéraux 24 610 Dessus de l appareil jusqu au plafond 72 1830 ...

Страница 20: ...er qu elle possède un filetage externe compatible Soupape de gaz marquée USE WITH TYPE 1 Inspectez le tuyau expédié avec l appareil pour vous assurer qu il n est pas endommagé N utilisez jamais un tuyau qui est endommagé ou obstrué Voir votre détaillant de gaz propane pour toute réparation Une fois l inspection du tuyau de gaz propane terminée branchez le bout du tuyau avec le raccord femelle au r...

Страница 21: ...haut pas plus de 5 pouces 127 mm au dessus de la base Les ouvertures seront d égale grandeur situées à 180 degrés l une de l autre 3 14 rad et sans obstruction c Chaqueouvertureauradesdimensionsminimumspourpermettrel entréed unetigede1 8 3 2mm dediamètre Les soupapes de bonbonne seront facilement accessibles et à portée de la main Une porte peut être installée sur l enclos pour accéder à la soupap...

Страница 22: ...RTISSEMENT Il est possible que les braises vitrifiées soient coupantes portez donc des lunettes de sécurité et des gants protecteurs pour les manipuler Ne pas changer ou substituer les braises vitrifiées fournies avec cet appareil Si vous les remplacez utilisez seulement des braises vitrifiées disponibles chez votre détaillant local autorisé 1 Videz soigneusement les braises vitrifiées sur le supp...

Страница 23: ...NOTE Le régulateur de pression pour les appareils au propane est muni d un dispositif de sécurité qui produit une situation de faible débit Si la soupape de l appareil est ouverte avant la soupape de la bonbonne le débit de gaz sera réduit produisant de très petites flammes Pour réinitialiser ce dispositif fermez la soupape de l appareil puis celle de la bonbonne de propane Débranchez ensuite l ad...

Страница 24: ...rsque l appareil est installé à des élévations dépassant 4 500 pieds aux États Unis il peut être nécessaire de réduire l indice du débit en changeant l injecteur de brûleur existant pour un autre plus petit L indice du débit doit être réduit au taux de 4 pour chaque 1 000 pieds au delà des 4 500 pieds au dessus du niveau de la mer à moins que la valeur calorifique du gaz soit déjà réduite auquel c...

Страница 25: ... conformément à ce manuel ou d utiliser uniquement des pièces spécifiquement approuvées pour cet appareil peut causer des dommages matériels ou des blessures corporelles COMPOSANTS RÉF N DE PIÈCE DESCRIPTION 1 QA 047 ANNEAU EXTÉRIEUR 2 W655 0176 SUPPORT À BÛCHES 3 W010 1030 BRÛLEUR 4 W080 0618 SUPPORT DE L INJECTEUR 5 W455 0076 INJECTEUR DE BRÛLEUR PL 43 W455 0077 INJECTEUR DE BRÛLEUR GN 25 W455 0...

Страница 26: ...26 www napoleonfireplaces com 8 1 9 2 5 4 3 7 10 6 ...

Страница 27: ...aces com HISTORIQUE D ENTRETIEN W415 0676 04 30 08 22 Historique d entretien Wolf Steel Cet appareil doit être entretenu annuellement selon son usage Nom du technicien Détaillant Date Travail effectué Problèmes particuliers ...

Страница 28: ...N415 0232 ...

Отзывы: