6
W45-0536 / C / 09.06.06
A. T
his fireplace is equipped with a pilot which must be
lit by hand while following these instructions exactly.
B. B
efore operating smell all around the fireplace area
for gas and next to the floor because some gas is
heavier than air and will settle on the floor.
C. Use only your hand to turn the gas control knob /
manual shut-off knob. never use tools. if the knob
will not turn by hand, do not try to repair it. call a
qualified service technician. force or attempted re
pair may result in a fire or explosion.
D. D
o not use this fireplace if any part has been under
water. immediately call a qualified service technician
to inspect the fireplace and replace any part of the
control system and any gas control which has been
under water.
gas knob
When lit for the first time, the fireplace will emit a slight odour
for a few hours. This is a normal temporary condition caused
by the curing of paints and lubricants used in the manufactur-
ing process and will not occur again. Simply open a window
to sufficiently ventilate the room.
After extended periods of non-operation such as following a
vacation or a warm weather season, the fireplace may emit a
• Do not touch any electric switch.
• Do not use any phone in your building.
• If you cannot reach your gas supplier, call the fire
department.
• Turn off all gas to the fireplace.
• Do not try to light any appliance.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s instructions.
Warning: if you do not follow these instructions exactly,
a fire or explosion may result causing property damage,
personal injury or loss of life. Initial lighting of the pilot and
main burners must be done with the glass door off.
Do not connect valve or wall switch to electricity. See insta
llation instructions.
When lighting and re-lighting, the gas knob cannot be turned
from pilot to off unless the knob it depressed slightly.
. STOP! read the safety information on the operating
label.
2. Turn off all electric power to the fireplace.
3. Turn the gas knob clockwise
to off.
4. Wait 5 minutes to clear out any gas. If you smell gas,
including near the floor, SToP! Follow “B” on the op
erating label. If you don’t smell gas, go to the next
step.
5. If the fireplace is equipped with a flame adjustment
valve, turn clockwise to off.
6. Find pilot located infront of the back log on the right
side.
7. Turn gas knob counter-clocKwise
to pilot.
8. This unit is equipped with an auto-spark.
Depress and hold gas knob . Keep knob fully de
pressed for one minute, then release. If pilot does not
continue to burn repeat steps 3 through 7.
9. With pilot lit, turn gas knob counter-clockwise
to on.
10. If equipped with flame adjustment valve, push
and turn knob to high.
. If equipped with remote on-off switch, main burner
may not come on when you turn the valve to on or
high. Remote switch must be in the on position to
ignite burner.
12. Turn on all electric power to the fireplace.
1.
Turn off all electric power to the fireplace if service is
to be performed.
2.
For a complete shut-down procedure: push in gas
control knob slightly and turn
clockwise to off.
Do not force.
3.
For a temporary shut-down procedure: set thermostat to
lowest setting or remote switch to off. Press and turn the
gas knob clockwise
to pilot.
OPERATING INSTRUCTIONS
FOR YOUR SAFETY READ BEFORE
LIGHTING INSTRUCTIONS
TO TURN OFF GAS
WHAT TO DO IF YOU SMELL GAS
figure 65
figure 66
slight odour for a few hours. This is caused by dust particles in
the heat exchanger burning off. open a window to sufficiently
ventilate the room.
Purge all gas lines with the glass door of the fireplace
open. Assure that a continuous gas flow is at the
burner before closing the door.
ON/OFF
KNOB
PILOT
SOLENOID
Содержание PARK AVENUE GD82NT
Страница 1: ... W415 0536 C 09 06 06 W415 0536 C 09 06 06 ...
Страница 10: ...10 W415 0536 C 09 06 06 figure 12 ...
Страница 25: ...25 W415 0536 C 09 06 06 dip switch number 0 on 1 off figure 64 ...
Страница 33: ...33 W415 0536 C 09 06 06 NOTES ...
Страница 34: ...34 W415 0536 C 09 06 06 NOTES ...