15
W415-0536 / C / 09.06.06
WARNING
Facing and/or finishing
material must never
overhang into the fireplace
opening.
Do not distort or force the frame
kit components.
When using a rough finish materi
-
al (i.e.; stone), maintain a ¼” - ½”
border from the framing
components.
NON-COMBUSTIBLE
FINISHING MATERIAL
59
3
/
8
"
21
3
/
4
"
32"
4"
4"
STUD
2"
FIRESTOP
SPACER
COMBUSTIBLE
MATERIAL
2"
SPACER
STAND OFF
NON-COMBUSTIBLE
72"
24"
62
1
/
8
"
29
"
44"
1"
MIN
1"
MIN
29"
22
1
/
2
"
2 FT.
MIN
10"
MIN
58
1
/
2
"
72"
29"
22
1
/
2
"
FIGURE 31
FRAMING
CLEARANCE TO COMBUSTIBLES
MAINTAIN THESE MINIMUM CLEARANCES TO COM
-
BUSTIBLES:
Fireplace framing - 0” to stand-offs (top, rear & sides)
Fireplace finishing - 4” to sides of fireplace opening.
- 21
3
/
4
” to top of fireplace opening.
FIGURE 28
FIGURE 29
FIGURE 30
It is best to frame your
fireplace
after it is
positioned
and
the
vent
system is
installed.
Use 2x4’s
and
frame to
local
build
-
ing codes.
Note:
In order to avoid the possibility of exposed insulation
or
vapour
barrier
coming
in
contact
with the
fireplace
body,
it is
recommended
that the
walls
of the
fireplace
enclosure
be
“finished”
(ie:
drywall/sheetrock),
as you
would
finish
any
other outside wall of a home. This will ensure that clearance
to combustibles is maintained within the cavity.
It is
not
necessary
to
install
a hearth
extension,
but the
fire
-
place
should
be
raised
to be
flush
with either the hearth or
the
finished
floor.
When
roughing
in
the
fireplace,
raise the
fireplace
to
accom
-
modate
for the
thickness
of the
finished
floor
materials,
i.e.
tile, carpeting, hard wood, which if not planned for will interfere
with the removal of the hearth strip, which must be removed
to
access
the
firebox.
O
bjects
placed
in
front
of the
fireplace
should
be
kept
a
mini
-
mum of 48” away from the front face.
For convenience, the stand-offs have been shipped flat.
Before framing, ensure the stand-offs are opened and
screwed in place.
IMPORTANT:
The Park Ave. requires
a minimum inside enclo-
sure height of 72”.
For temperature require-
ments, this area must be
left unobstructed.
It is recommended that
the enclosure be ventilat-
ed at the top and bottom
to circulate the hot air.
Non-combustible
finishing material
(ie: cement board,
brick, stone, tile)
may be
used
to
fin
-
ish the front of the
unit.
Содержание PARK AVENUE GD82NT
Страница 1: ... W415 0536 C 09 06 06 W415 0536 C 09 06 06 ...
Страница 10: ...10 W415 0536 C 09 06 06 figure 12 ...
Страница 25: ...25 W415 0536 C 09 06 06 dip switch number 0 on 1 off figure 64 ...
Страница 33: ...33 W415 0536 C 09 06 06 NOTES ...
Страница 34: ...34 W415 0536 C 09 06 06 NOTES ...