Napoleon PARK AVENUE GD82NT Скачать руководство пользователя страница 1

W45-0536  / C / 09.06.06

W45-0536 / C / 09.06.06

Содержание PARK AVENUE GD82NT

Страница 1: ... W415 0536 C 09 06 06 W415 0536 C 09 06 06 ...

Страница 2: ...l your gas supplier from a neighbor s phone Follow the gas supplier s instructions Installation and service must be performed by a qualified installer service agency or the gas supplier Follow the installation directions 1 2 3 4 5 6 Do not store gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance If this fireplace is not properly installed a house fire ma...

Страница 3: ...d out of traffic and away from furniture and draperies Clothing or other flammable material should not be placed on or near the fireplace Any safety screen or guard removed for servicing must be replaced prior to operating the fireplace It is imperative that the control compartments burners and circulating blower and its passageway in the fireplace and venting system are kept clean The fireplace a...

Страница 4: ...nty This limited warranty further does not cover any scratches dents corrosion or discolouring caused by excessive heat abrasive and chemical cleaners nor chip ping on porcelain enamel parts mechanical breakage of phazer logs and embers nor any venting components used in the installation of the fireplace Napoleon warrants its stainless steel burners against defects in workmanship and material for ...

Страница 5: ... know the specifics that apply to your area for example in Massachusetts State The fireplace damper must be removed or welded in the open position prior to installation of a fireplace insert or gas log A carbon monoxide detector is required in all rooms containing gas fired appliances The appliance off valve must be a T handle gas cock The flexible connector must not be longer than 36 inches The a...

Страница 6: ...feet using flexible venting The maximum number of allowable 4 vent connections is three horizontally or vertically exclud ing the fireplace and the air terminal connections For optimum flame appearance and fireplace performance keep the vent length and number of elbows to a minimum figure 3 Care of glass and plated parts Horizontal runs may have a 0 inch rise per foot in all cases using simpson du...

Страница 7: ...ormulas are met this vent configuration is acceptable figure 5 90 90 90 H1 V2 H2 V1 horizontal vent run PLUS OFFSET in feet HT The shaded area within the lines represents acceptable values for HT and VT for the following symbols used in the venting calculations and examples are greater than equal to or greater than less than equal to or less than Ht total of both horizontal vent lengths Hr and off...

Страница 8: ...T 4 2 VT Formula 2 HT VT 24 75 feet Example 2 Example 3 V1 4 ft V2 1 5 ft VT V1 V2 4 1 5 5 5 ft H1 2 ft H2 1 ft H3 1 ft H4 1 5 ft HR H1 H2 H3 H4 2 1 1 1 5 5 5 ft HO 03 four 90 elbows 90 03 360 90 8 1 ft HT HR HO 5 5 8 1 13 6 ft HT VT 13 6 5 5 19 1 ft Formula 1 HT 4 2 VT 4 2 VT 4 2 x 5 5 23 1 ft 13 6 23 1 Formula 2 HT VT 24 75 feet 19 1 24 75 Since both formulas are met this vent configuration is a...

Страница 9: ...the required vertical rise VT for the required horizontal run HT figure 11 V3 1 5 ft VT V1 V2 V3 2 1 1 5 4 5 ft H1 6 ft H2 2 ft HR H1 H2 6 2 8 ft HO 03 four 90 elbows 90 03 90 90 90 90 90 8 1 ft HT HR HO 8 8 1 16 1 ft HT VT 16 1 4 5 20 6 ft Formula 1 HT 3VT 3VT 3 x 4 5 13 5 ft 16 1 13 5 Since this formula is not met this vent configuration is unacceptable Formula 2 HT VT 40 feet 20 6 40 Since only...

Страница 10: ...10 W415 0536 C 09 06 06 figure 12 ...

Страница 11: ... up the 1 air space around the pipe INSTALLATION WALL AND CEILING PROTECTION VERTICAL INSTALLATION VENT PIPE SHIELD VENT PIPE COLLAR FIGURE 15 figure 14 11 11 figure 13 This application occurs when venting through an exterior wall Having determined the air terminal location cut and frame a hole in an exterior wall with a minimum rectangle opening of 12 x 11 IMPORTANT For optimum performance The st...

Страница 12: ...h 3 8 screws Apply a heavy bead of the high temperature sealant 3 Using the 7 diameter flexible aluminum liner slide over the outer combustion air sleeve of the air terminal and secure with 3 8 screws Seal as before 4 Insert the liners through the firestop maintaining the required clearance to combustibles Secure to the exterior 4 7 7 FIGURE 18 Use only approved aluminum flexible liner kits marked...

Страница 13: ... with a twisting motion to ensure that both the terminal sleeves engage into the vent pipes and sealant Secure the terminal to the exterior wall and make weather tight by sealing with caulking not supplied 1 Install the 4 diameter aluminium flexible liner to the fireplace Secure with 3 screws and flat washers Seal the joint and screw holes using the high temperature sealant W573 0007 not provided ...

Страница 14: ...g giv ing a 3 4 margin all around Fasten to the roof Do NOT nail through the lower portion of the flashing Make weather tight by sealing with caulking Where possible cover the sides and top edges of the flashing with roofing material 7 Apply a heavy bead of waterproof caulking 2 inches above the flashing Slide the storm collar around the air ter minal connector and down to the caulking Tighten to ...

Страница 15: ...commended that the walls of the fireplace enclosure be finished ie drywall sheetrock as you would finish any other outside wall of a home This will ensure that clearance to combustibles is maintained within the cavity It is not necessary to install a hearth extension but the fire place should be raised to be flush with either the hearth or the finished floor When roughing in the fireplace raise the firepla...

Страница 16: ... operating the unit It is necessary to hard wire this fireplace Permanently framing the fireplace with an enclosure requires the fireplace junction box to be hardwired This fireplace must be electrically connected and grounded in accordance with local codes In the absence of local codes use the current CSA C22 1 canadian electrical code in Canada or the ANSI NFPA 70 1996 national electri cal code ...

Страница 17: ...sides of the door lift the door out from the retainer along the bottom of the door LOG SHIPPING BRACKET Before installing the logs you must first remove the log ship ping brackets Lift up to remove Log SHIPPING BRACKET door REMOVAL FINISHING Decorative brick panels must be installed before the logs See installation instructions supplied with the panel kit Log Placement phazertm logs exclusive to N...

Страница 18: ...blower and lift through blower access opening figure 37 REMOVE 2 SCREWS Your PARK AVENUE comes equipped with our Night Light The light has been pre wired and is controlled from the remote control If in the event the lamp or lens needs to be replaced follow the instructions below Unplug the wireharness transformer from the junction box inside the fireplace NIGHT LIGHT REPLACEMENT SCREWS LENSE FRAME...

Страница 19: ...e Note Refractory panels require a 24 hour curing period on a low flame 3 2 1 HERRINGBONE PATTERN ILLUSTRATED When shipped the brick panels range in varying shades of tan During initial use the panels will emit a slight odor for a few hours This is a normal condition that will not occur again Simply open a window to sufficiently ventilate the room The appearance of the panels will permanently ligh...

Страница 20: ...illustrated in Fig 47 3 Lift and hook the faceplate over the spacers Then push the top of the faceplate back until it comes in contact with the face plate bracket then secure on the underside by using the 2 1 4 20 screws provided as illustrated in Fig 49 SCREW SPACER NOTE A 1 4 gap must be maintained between the front and all finishing material due to regular removal afk wi face kit installation f...

Страница 21: ...low access and removal of the remote receiver and spark module If valve replacement is necessary following steps 1 and 2 above then proceed with the following 3 Door Removal The glass door is secured at the top front edge of the fireplace Pull the latch forward then lift hook out from slot in the door Pivot door forward then lift out from retainer along the bottom edge of the firebox 4 Burner Remo...

Страница 22: ...ontrol is on otherwise turn on the Remote Control and wait 5 seconds Select the manual flame height until the cursor small triangle is to the left of the big flame Figure 54 Use the RIGHT or LEFT button to set the OPERATION MAINTENANCE FIREPLACE OPERATION HAND HELD REMOTE OPERATIONS desired flame height Six flame levels are included from 1 minimum to 6 maximum An acoustic signal from the Receiver ...

Страница 23: ... lock icon is lit To activate this function press the ON OFF button and within one second the UP key To reactivate the remote control buttonss follow the same se quence press ON OFF key and within one second press the UP button POWER FAILURE During main power loss it is not possible to turn on the appli ance with the Remote Control It is possible to turn the appli ance on manually using the Backup...

Страница 24: ... the address of the Transmitter press the UP key to increase and DOWN to decrease it A beep from the Receiver will confirm the same address as the Transmitter Press LEFT key to exit this function Note The address of the Receiver is acquired only at its power on Changing the address while the Receiver is powered will not have any effect To change the address of the Receiver disconnect the power cab...

Страница 25: ...25 W415 0536 C 09 06 06 dip switch number 0 on 1 off figure 64 ...

Страница 26: ...ity See insta llation instructions When lighting and re lighting the gas knob cannot be turned from pilot to off unless the knob it depressed slightly 1 STOP read the safety information on the operating label 2 Turn off all electric power to the fireplace 3 Turn the gas knob clockwise to off 4 Wait 5 minutes to clear out any gas If you smell gas including near the floor STOP Follow B on the op era...

Страница 27: ...ified service person The fireplace area must be kept clear and free of combustible materials gasoline or other flammable vapours and liquids The flow of combustion and ventilation air must not be ob structed 1 In order to properly clean the burner and pilot assem bly remove the logs to expose both assemblies 2 Keep the control compartment logs burner air shut ter opening and the area surrounding t...

Страница 28: ...ON KIT 56 GA 72 HOT AIR EXHAUST KIT 57 GA 70 EXTENSION KIT 5FT FLEX VENT 58 w010 0370 wall support assembly 59 w175 0001 4 coupler 60 w175 0013 7 coupler 61 W175 0239 CONVERSION KIT ng to lp 62 W175 0240 CONVERSION KIT lp to ng 63 GD811 KT HERRINGBONE SANDSTONE BRICK KIT 64 W135 0148 ANDIRON 65 GD812 KT REFRACTORY PANEL KIT 66 RFK82 RECtangle facing kit 67 afk82 arched facing kit 68 rfk82wI wrough...

Страница 29: ...29 W415 0536 C 09 06 06 44 43 56 55 53 19 9 22 21 20 18 23 32 62 68 AUX ON 0 00 00 ON OFF FEATURE SELECT 63 26 24 25 27 36 35 2 13 11 15 14 12 66 49 50 51 7 1 3 4 52 67 5 6 ...

Страница 30: ...rn around the thermocouple Pilot flame is not engulfing the thermocouple Thermocouple shorting faulty loosen and tighten thermocouple clean thermocouple and valve connection replace thermocouple replace valve Faulty valve replace Main burner flame is a blue lazy transparent flame Blockage in vent remove blockage In really cold conditions ice buildup may occur on the terminal and should be removed ...

Страница 31: ...oken or frayed replace the electrode if the ceramic insulator is cracked or broken replace the push button ignitor No spark at pilot burner fill the tank Out of propane gas Spark gap is incorrect spark gap should be 0 150 to 0 175 5 32 to 11 64 approx from the electrode tip and the pilot burner To ensure proper electrode loca tion tighten securing nut finger tight plus 1 4 turn No gas at the pilot...

Страница 32: ...32 W415 0536 C 09 06 06 Fireplace Service History This fireplace must be serviced annually depending on usage DATE DEALER NAME SERVICE TECHNICIAN NAME SERVICE PERFORMANCE SPECIAL CONCERNS ...

Страница 33: ...33 W415 0536 C 09 06 06 NOTES ...