W415-0585 / B / 11.28.06
6
To operate this hi-efficiency fireplace as a basic system, the
blower is not required, however, to enhance its efficiency a
blower is recommended.
A blower kit (NZ62)
may be purchased
with the op-
tion of adding up to one additional blower. These blowers
are installed in the bottom of the unit and are used to direct
the heat into the room where the fireplace is located. The
blowers are controlled, by a variable speed switch, located
inside the fireplace.
A thermostAtic Air coNtrol (NZ690kt)
may be
used for constant heat,
complete with automatic damper and
thermostat, wall mounted in the room containing the fireplace,
and at least
10 feet (minimum) from the fireplace
.
A hot Air grAvity veNt system (NZ220)
may be
used to distribute heat to an adjoining room (located either
above, or beside the room containing the fireplace) by way
of vents, eliminating the need of an additional blower. While
this system may be used in conjunction with the optional
blowers, it could reduce the flow of hot air being distributed
to additional rooms. It must be experimented with and the
dampers adjusted manually to suit your requirements. This
may take a few attempts; thereafter adjustments should no
longer be required as is normally experienced with your
central heating system registers.
The heat shield cover plate must be removed before
installing the gravity vent. The hot air vent must be in-
stalled in an upward direction! NEVER install in a down-
ward direction
. Figure 6. Th
e hot air gravity vent system
is not to be connected to a central heating system (for
this application use the NZ62CH). This option may not
be used in mobile homes.
No more than
two
hot air gravity vents can be installed to
fireplace. Individual vent runs are not to exceed 10 feet.
All hot air gravity vents must be insulated.
A ceNtrAl heAtiNg system (NZ62ch)
may be
used to heat rooms up to 50 feet from the unit. A wall mounted
thermostat located in the room to be heated controls the
blower supplying warm air from the room containing the fire
-
place. If a hot air duct system exists, the central heat blower
may safely be tied into this system to reduce the amount of
new ducting required. Consult with a heating specialist to
ensure a proper duct layout for your home. If the NZ62CH
is installed at the bottom of the unit, it could introduce a cool
draft into the room that the fireplace is installed in.
A hot Air distributioN kit (gA-566)
may be used
to distribute warm air from the fireplace base (only) into a
separate location in the home.
These options may be incorporated with one another. If the
optional blowers are to be installed, make provision during
framing to route a 110 volt power line to the fireplace. Detailed
installation instructions are included with each venting kit.
figure 6
hI-EFFICIENCY hEATING
FIVE OPTIONS
STOVE TOP
figure 4
HEAT SHIELd COVER PLATE
figure 5b
figure 5
When attached to the top or sides of the unit, it provides a
higher heat output.
This option may not be used in
mobile homes.
REMOTE VIEWING OPTIONS
NOTE: MASONRY REMOTE VENTING OPTIONS COME OFF THE
SIDE INSTEAD OF THE TOP.
NO
DUCTING
CENTRAL HEATING
OPTION
GRAVITY VENT
OPTION (1 DUCT)
CENTRAL HEATING &
GRAVITY VENT OPTION
GRAVITY VENT
OPTION (2 DUCT)
*
RIGHT SIDE
ONLY
NO
DUCTING
CENTRAL HEATING &
GRAVITY VENT OPTION
NZ-26:
NZ-26WI: