Napoleon NZ-26 Скачать руководство пользователя страница 1

W415-0585 / B / 11.28.06

1

INSTALLATION

AND

OPERATING INSTRUCTIONS

Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 4Y8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030

(705)721-1212

 fax(705)722-6031 

 www.napoleonfireplaces.com 

 [email protected]

R-2000

INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.

If the information in these instructions is not followed 

exactly, a fire or explosion may result causing property 

damage, personal injury or death.

SOLID FUEL BURNING - ZERO CLEARANCE

Installation and operation instructions for Hi-Tech 

listed fireplace

THIS FIREPLACE HAS BEEN TESTED AND LISTED BY INTERTEK TESTING SERVICES  TO STANDARDS: CAN/ULC S610, UL 127, FOR ZERO CLEARANCE FIREPLACES, AND TO ULC 
S639 FOR STEEL LINER ASSEMBLIES FOR SOLID FUEL BURNING MASONRY FIREPLACES. CERTIFIED UNDER USA ENVIRONMENTAL PROTECTION AGENCY (E.P.A.) JULY 1990 AND 

THE OREGON DEPARTMENT OF ENVIRONMENTAL  QUALITY (D.E.Q.) PARTICULATE EMISSION STANDARDS

NZ-26

NZ-26WI

Содержание NZ-26

Страница 1: ...exactly a fire or explosion may result causing property damage personal injury or death SOLID FUEL BURNING ZERO CLEARANCE Installation and operation instructions for Hi Tech listed fireplace THIS FIR...

Страница 2: ...W415 0585 B 11 28 06 WARNINGS SAFETY PRECAUTIONS...

Страница 3: ...emoval Procedures 17 Maintenance Gasket Baffle Replacement NZ 26 Door Glass Replacement NZ 26WI Door Glass Replacement Creosote Formation And Removal Run Away or Chimney Fire Fire Extinguishers and Sm...

Страница 4: ...urchaser the wholesale price of any warranted but defective part s After the first year napoleon will not be responsible for installation labour or any other costs or expenses related to the reinstall...

Страница 5: ...discol oration to the gold plated door internal damage to the fireplace or a house and or chimney fire All venting connections must be in compliance with the chimney manufacturers installation instru...

Страница 6: ...ating system for this application use the NZ62CH This option may not be used in mobile homes No more than two hot air gravity vents can be installed to fireplace Individual vent runs are not to exceed...

Страница 7: ...d insulation or vapour bar rier coming in contact with the fireplace body it is recommended that the walls of the fireplace enclosure be finished ie drywall sheetrock as you would finish any other out...

Страница 8: ...nts figure 7c Finishing Requirements Note In order to avoid the possibility of exposed insulation or vapour bar rier coming in contact with the fireplace body it is recommended that the walls of the f...

Страница 9: ...diation shield is required The chimney should not be built with an offset angle in excess of 45 in Canada and 30 in USA CHIMNEY INSTALLATION The chimney must extend at least 3 feet above its point of...

Страница 10: ...wo 15 30 or 45 elbows Minimum overall chimney height is 11 feet Double off set with four 15 30 or 45 elbows Minimum overall chimney height is 11 feet The first flue offset closest to the top of the un...

Страница 11: ...e flashing giving a 3 4 margin all around Fasten to the roof on the top and sides do not nail through the lower portion of the flashing Make weather tight by sealing with caulking Where possible cover...

Страница 12: ...removals the bottom flame spreader must be taped to the top spreader to ease top brick and baffle removal and to avoid damaging the fibre baffles 1 1 2 gasket rope location rear bricks Unscrew and re...

Страница 13: ...lace chimney and the surrounding enclosure top flame spreader bottom flame spreader fibre baffle 1 of 2 shown top firebrick 1 of 2 shown 3a 3b baffle support bracket figures 29 figures 30 figures 32 I...

Страница 14: ...blower single blower installation to be done by a qualified installer and must be electrically connected and grounded in accordance with local codes In the absence of local codes use the current CSA C...

Страница 15: ...through the chimney The amount of draft in your chimney depends on the length of the chimney local geography nearby obstruc tions and other forces Adjusting the draft control regulates the temperatur...

Страница 16: ...l occurrence and does not pose a safety hazard The paint may also smell a little for the first few fires as it cures and you may wish to open a door or window to alleviate the smell To start a brisk f...

Страница 17: ...ce with 1 2 fibreglass rope if necessary To remove the door open and lift out remove the screws and brackets holding the glass in place Remove all broken glass Wrap the edges of the new glass with a U...

Страница 18: ...not illustrated for further information contact your napoleon dealer REPLACEMENTS PART No DESCRIPTION 33 111kt outside air kit 34 NZ 690kt thermostatic air control kit 35 NZ 62 CH central heating kit...

Страница 19: ...W415 0585 B 11 28 06 19...

Страница 20: ...ly drawn into the chimney there may be a downdraft or cold air in the chimney Roll up some newspaper light it and place it near the fireplace flue until the chimney begins to draw During a firing open...

Страница 21: ...W415 0585 B 11 28 06 21 Wolf Steel Fireplace Service History This fireplace must be serviced annually depending on usage Date Service Technician Name Service Performed Special Concerns Dealer Name...

Страница 22: ...W415 0585 B 11 28 06 22 NOTES...