4”
BUILT-IN UNIT OPENING DIMENSIONS
MODEL
OPENING DIMENSIONS
NOTES
W
D
H
BILEX485
29 3/4”
756mm
21 3/8”
543mm
7 1/2”
191mm
SIDE
BURNER
12 3/4”
324mm
16 1/2”
419mm
4 1/2”
114mm
OPENING OF AT LEAST 5 SQ (32cm
2
) IN MUST BE PROVIDED FOR
COMBUSTION AIR FOR SIDE BURNER.
MINIMUM 10 SQ IN (65cm
2
)
OF VENTILATION REQUIRED ON
EACH END OF CABINET
W
W
H
H
D
6” (152mm)
GAS INLET OPENING
OUTDOOR GFI ELECTRICAL OUTLET
REC
OMMENDED - LOCATE ON SAME SIDE
OF GRILL AS ROTISSERIE BRACKET.
W
H
D
1¾”
(44mm)
1¾”
(44mm)
BUILT-IN SIDEBURNER
GAS INLET OPENING
NON-C
OMBUS
TIBLE MA
TERIAL
Note: Accessory frames
overlap opening by 1 ¾”
(
4cm)
on all 4 sides.
WARNING!
CABINET FRAME, CABINET AND
COUNTER TOP MUST BE MADE FROM NON-COMBUSTIBLE
MATERIAL.
WARNING!
A propane tank can
not be stored below the gas grill.
WARNING!
This grill is designed for Non-combustible enclosures only, and must be installed and
serviced by a qualified installer to local codes.
WARNING!
Use only non-combustible materials (certified to ASTM E-136) such as steel studs,
cement board, ceramic tile, marble, paint etc. When adding finishing materials to the appliance.
Do not use wood or drywall.
34” (864mm)
RECOMMENDED
ELECTRICAL OPENING