SAMPLES OF ALLOWABLE PLENUM/DUCTING ARRANGEMENTS:
“ADD ON”
WOOD
FURNACE
EXISTING
FURNACE
“ADD ON”
WOOD
FURNACE
EXISTING
FURNACE
DIVIDER
“ADD ON”
WOOD
FURNACE
ELECTRIC
FURNACE
(downflow
or counterflow)
ALLOWABLE
PROHIBITED
HORIZONTAL
EXISTING
FURNACE
“ADD ON”
WOOD
FURNACE
H
“ADD ON”
WOOD
FURNACE
EXISTING
FURNACE
(downflow
or counterflow)
or counte
“ADD ON”
WOOD
FURNACE
HORIZONTAL
EXISTING
FURNACE
H
○
For installations on combustible
fl
ooring an ember stop protective
fl
oor covering must be installed.
○
An ember stop of minimum 0.015" thick sheet metal extending from 18" off the front of the
fi
rebox door
right through protruding out the back of the furnace and with a width which extends 9" each side of the
fi
rebox door is required.
○
Carpet or other
fl
oor covering shall be removed before placement of ember stop sheet.
○
Refer to Section 7.1 of CAN/CSA-B365-01 for complete details of
fl
oor protection.
6.6 EMBER
STOP