THIS GAS FIREPLACE SHOULD BE INSTALLED AND
SERVICED BY A QUALIFIED INSTALLER

  to conform with

local codes. Installation practices vary from region to re-
gion and  it is important to know the specifics that apply to
your area, for example: in Massachusetts State:

• The appliance off valve must be a “T” handle gas cock.
• The flexible connector must not be longer than 36 inches.
• The appliance is not approved for installation in a bedroom or

bathroom unless the unit is a direct vent sealed combustion
product.

• WARNING: This product must be installed by a licensed

plumber or gas fitter when installed within the commonwealth
of Massachusetts.

• Un-vented room heater shall be installed in accordance with

527 CMR 30.00 and 248 CMR 3.00 through 7.00.

• Sellers of un-vented propane or natural gas-fired

space/room heaters shall provide to each purchaser a copy
of 527 CMR 30.00 upon the sale of the unit from
http://www.napoleonfireplaces.com/Webshare/
installation_manuals/mass_requirements.pdf

 In absence of local codes, install the GVF42 to the current
National Fuel Gas Code, ANSI Z223.1 Installation Code

which can be obtained from:

American Nation Standards Institute Inc.

1430 Broadway

New York, NY 10018

or

National Fire Protection Association Inc.

Batterymarch Park

Quincy, MA 02269

The fireplace and its individual shutoff valve must be dis-
connected from the gas supply piping system during any
pressure testing of that system at test pressures in ex-
cess of 1/2 psig (3.5 kPa). The fireplace must be isolated
from the gas supply piping system by closing its individual
manual shutoff valve during any pressure testing of the
gas supply piping  system at test pressures equal to or
less than 1/2 psig (3.5 kPa).
When the fireplace is installed directly on carpeting, vinyl
tile or other combustible material other than wood floor-
ing, the fireplace shall be installed on a metal or wood
panel extending the full width and depth.
If the optional fan or blower is installed, the junction box
must be electrically connected and grounded in accord-
ance with local codes. In the absence of local codes, use
the current ANSI/NFPA 70 NATIONAL ELECTRICAL CODE
in the United States.

Suitable for mobile home installation where the mobile
home has been permanently placed on its site. This
heater must not be installed in a bedroom or bathroom.

This fireplace may be installed in an aftermarket per-
manently located, manufactured (mobile) home, where
not prohibited by local codes.

This fireplace is only for use with the type of gas indi-
cated on the rating plate. This fireplace is not convert-
ible for use with other gases, unless a certified kit is
used.

FOR YOUR SATISFACTION, THIS FIREPLACE HAS BEEN
TEST-FIRED TO ASSURE ITS OPERATION AND QUAL-
ITY!

  Maximum input is 30,000 BTU/hr for natural gas and

propane. When the fireplace is installed at elevations above
2,000ft, and in the absence of specific recommendations
from the local authority having jurisdiction, the certified
high altitude input rating shall be reduced at the rate of 4%
for each additional 1,000ft.
Minimum inlet gas supply pressure is 4.5 inches water
column for natural gas and 11 inches water column for
propane. Maximum inlet gas pressure is 7 inches water
column for natural gas and 13 inches water column for
propane. Manifold pressure under flow conditions is 3.5
inches water column for natural gas and 10 inches water
column for propane.

No external electricity (110 volts or 24 volts) is required
for the gas system operation.

Expansion / contraction noises during heating up and cool-
ing down cycles are normal and are to be expected.

This heater is equipped with a pilot light safety
system referred to as an 

OXYGEN DEPLETION

SENSOR

 

and is designed to turn off the heater if

not enough fresh air is available.

Use only accessories designed for and

listed with your specific fireplace.

Not designed for use with a glass door.

Screen must be closed when appliance is

in operation.

CARBON MONOXIDE POISONING

MAY LEAD TO DEATH

Early signs of carbon monoxide poisoning re-
semble the flu, with headache, dizziness and/
or nausea. If you have these signs, the heater
may not be working properly. 

Get fresh air

at once! Have heater serviced.

Some people---pregnant women, persons
with heart or lung disease, anaemia, those
under the influence of alcohol, those at high
altitudes--- are more affected by carbon mon-
oxide than others.

GENERAL INSTRUCTIONS

GENERAL INFORMATION

Содержание GVF42N

Страница 1: ...exactly a fire or explosion may result causing property damage personal injury or death FOR YOUR SAFETY Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or a...

Страница 2: ...oung children and animals away when the fireplace is hot Due to high temperatures the heater should be located out of traffic and away from furniture and draperies Clothing or other flammable material...

Страница 3: ...d company official Labour costs to the account of the prior approval of an authorized company official Labour costs to the account of the prior approval of an authorized company official Labour costs...

Страница 4: ...the current ANSI NFPA 70 NATIONAL ELECTRICAL CODE in the United States Suitable for mobile home installation where the mobile home has been permanently placed on its site This heater must not be insta...

Страница 5: ...d ventilation air Add the Btu hr of all fuel burning appliances located within the space such as gas furnace gas water heater etc Do not include direct vent gas appliances which draw their input and o...

Страница 6: ...he outside atmos phere have a continuous water vapour retarder with a rating of 1 perm 6 x 10 11 kg per pa sec m2 or less with openings gasketed or sealed and b Weather stripping has been added on ope...

Страница 7: ...ide wall of a home This will ensure that clearance to combustibles is maintained within the cavity It is not necessary to install a hearth extension with this fireplace system When roughing in the fir...

Страница 8: ...that the front face is offset with the front edge of the corner post approx Centre the nailing tab vertically on the corner post Figure 8 a Drill through the centre of the top and bottom slots in the...

Страница 9: ...ck the burner ports Blocked burner ports can cause an incorrect flame pattern carbon deposits and delayed ignition PHAZERTM logs glow when exposed to direct flame 4 Place the bottom of the left crosso...

Страница 10: ...re the hood using the screws removed in step 1 Ensure that the louvre brackets are positioned in front of the hood CURTAIN MESH SCREWS HOOD CURTAIN MESH FIGURES 12 a c The curtain mesh must be kept fu...

Страница 11: ...17 UPPER LOUVRES Insert the louvre tabs into the slots located at the top left and right corners of the unit SLOT TAB A LOWER LOUVRES Insert the hinge clips into the slots located at the bottom left a...

Страница 12: ...nto the clip C and up against the threaded stud B at the other end The blower must be able to be positioned entirely onto the pad Tilt the blower onto its side Slide it past the controls and into the...

Страница 13: ...IGURE27 This optional kit is meant to be used only in conjunction with the GD65 Fan Kit which may be ordered from your Wolf Steel Napoleon dealer With the thermostatic sensor option the fan when turne...

Страница 14: ...T FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLO SION MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE GAS KNOB OXYGEN DEPLETION SENSOR If heater shuts off do not relight until yo...

Страница 15: ...IREPLACE CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servic ing This heater should be...

Страница 16: ...R NATURAL GAS 28 GD825P VALVE REGULATOR PROPANE 29 W500 0033 VARIABLE SPEED SWITCH WALL MOUNTING PLATE 30 GZ550 KT BLOWER KIT 31 GD65 FAN KIT 32 GD36 THERMOSTATIC SENSOR CONTROL KIT FOR USE WITH GD65...

Страница 17: ...l System is not correctly purged purge the gas line Thermocouple shorting faulty loosen and tighten thermocouple clean thermocouple and valve connection replace Oxygen Depletion Sensor System test and...

Страница 18: ...n main burner comes on when gas knob is turned to ON po sition Wall switch is mounted up side down reverse Faulty valve replace replace Remote wall switch is grounding check for ground short repair gr...

Страница 19: ...19 W415 0379 B 08 03 05 Wolf Steel Fireplace Service History This fireplace must be serviced annually depending on usage Date Service Technician Name Service Performed Special Concerns Dealer Name...