This procedure must be performed by a qualified

service person!

Inspect the pilot for any visible contamination or debris
(usually lint, pet hair, spider webs, carpet fibre, etc.) and
remove.
Disconnect the pilot from the pilot tubing line. Using a 

7

/

16

wrench, remove the injector from the pilot housing. Blow
out the housing in the same direction as the gas flow.
Re-install the injector and the pilot tube, turn on the gas
and check for leaks.
If this does not improve the performance, replace the pilot
with 

an exact replacement.

 The device is tamper resist-

ant with no field serviceable parts.

Air shutter adjustment must only be done by a

qualified gas installer!

Closing the air shutter will cause a more yellow flame, but
can lead to carboning.

WARNING:

 Carbon can be distributed in surrounding liv-

ing area if the air shutter is improperly adjusted.
Opening the air shutter will cause a more blue flame, but
can cause flame lifting from the burner ports. The flame
may not appear yellow immediately; allow 15 to 30 min-
utes for the final flame colour to be established.
Opening the air shutter will also reduce exhaust odours
smelled within the room. 

See Trouble Shooting Guide.

CORRECT PILOT

FLAME

INCORRECT PILOT

FLAME

AIR SHUTTER OPENINGS

TURN OFF THE GAS AND ELECTRICAL POWER

BEFORE SERVICING THE FIREPLACE.

CAUTION: Label all wires prior to disconnection when
servicing controls. Wiring errors can cause improper and
dangerous operation. Verify proper operation after servic-
ing. This heater should be inspected and serviced before
use and at least annually by a qualified service person.
The fireplace area must be kept clear and free of combus-
tible materials, gasoline or other flammable vapours and
liquids. The flow of combustion and ventilation air must
not be obstructed.

1. 

 In order to properly clean the burner and oxygen deple-

tion sensor system, remove the logs to expose both as-
semblies.

2.

  Keep the control compartment, logs, burner, air shutter

opening and the area surrounding the logs clean by vacu-
uming or brushing, 

at least once a year

.

3.  

Check to see that all burner ports are burning. Clean

out any of the ports which may not be burning or are not
burning properly.

4. 

 Check to see that the pilot flame is large enough to

engulf the thermocouple and thermopile and promptly ig-
nites the main burner.

5.

  Replace the cleaned logs as instructed. 

Failure to prop-

erly position the logs may cause carboning  which can
be distributed in the surrounding living area.

6.  

Check to see that the main burner ignites completely

on all openings when the gas knob for the burner is turned
on. A 5 to 10 second total light-up period is satisfactory. If
ignition takes longer, consult your Napoleon dealer / dis-
tributor.

FIGURES 28

FIGURES 29

NG

3/16"

LP

1/4"

MAINTENANCE

OXYGEN DEPLETION SENSOR PILOT

CLEANING

VENTURI ADJUSTMENT

Содержание GVF42N

Страница 1: ...exactly a fire or explosion may result causing property damage personal injury or death FOR YOUR SAFETY Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or a...

Страница 2: ...oung children and animals away when the fireplace is hot Due to high temperatures the heater should be located out of traffic and away from furniture and draperies Clothing or other flammable material...

Страница 3: ...d company official Labour costs to the account of the prior approval of an authorized company official Labour costs to the account of the prior approval of an authorized company official Labour costs...

Страница 4: ...the current ANSI NFPA 70 NATIONAL ELECTRICAL CODE in the United States Suitable for mobile home installation where the mobile home has been permanently placed on its site This heater must not be insta...

Страница 5: ...d ventilation air Add the Btu hr of all fuel burning appliances located within the space such as gas furnace gas water heater etc Do not include direct vent gas appliances which draw their input and o...

Страница 6: ...he outside atmos phere have a continuous water vapour retarder with a rating of 1 perm 6 x 10 11 kg per pa sec m2 or less with openings gasketed or sealed and b Weather stripping has been added on ope...

Страница 7: ...ide wall of a home This will ensure that clearance to combustibles is maintained within the cavity It is not necessary to install a hearth extension with this fireplace system When roughing in the fir...

Страница 8: ...that the front face is offset with the front edge of the corner post approx Centre the nailing tab vertically on the corner post Figure 8 a Drill through the centre of the top and bottom slots in the...

Страница 9: ...ck the burner ports Blocked burner ports can cause an incorrect flame pattern carbon deposits and delayed ignition PHAZERTM logs glow when exposed to direct flame 4 Place the bottom of the left crosso...

Страница 10: ...re the hood using the screws removed in step 1 Ensure that the louvre brackets are positioned in front of the hood CURTAIN MESH SCREWS HOOD CURTAIN MESH FIGURES 12 a c The curtain mesh must be kept fu...

Страница 11: ...17 UPPER LOUVRES Insert the louvre tabs into the slots located at the top left and right corners of the unit SLOT TAB A LOWER LOUVRES Insert the hinge clips into the slots located at the bottom left a...

Страница 12: ...nto the clip C and up against the threaded stud B at the other end The blower must be able to be positioned entirely onto the pad Tilt the blower onto its side Slide it past the controls and into the...

Страница 13: ...IGURE27 This optional kit is meant to be used only in conjunction with the GD65 Fan Kit which may be ordered from your Wolf Steel Napoleon dealer With the thermostatic sensor option the fan when turne...

Страница 14: ...T FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLO SION MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE GAS KNOB OXYGEN DEPLETION SENSOR If heater shuts off do not relight until yo...

Страница 15: ...IREPLACE CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servic ing This heater should be...

Страница 16: ...R NATURAL GAS 28 GD825P VALVE REGULATOR PROPANE 29 W500 0033 VARIABLE SPEED SWITCH WALL MOUNTING PLATE 30 GZ550 KT BLOWER KIT 31 GD65 FAN KIT 32 GD36 THERMOSTATIC SENSOR CONTROL KIT FOR USE WITH GD65...

Страница 17: ...l System is not correctly purged purge the gas line Thermocouple shorting faulty loosen and tighten thermocouple clean thermocouple and valve connection replace Oxygen Depletion Sensor System test and...

Страница 18: ...n main burner comes on when gas knob is turned to ON po sition Wall switch is mounted up side down reverse Faulty valve replace replace Remote wall switch is grounding check for ground short repair gr...

Страница 19: ...19 W415 0379 B 08 03 05 Wolf Steel Fireplace Service History This fireplace must be serviced annually depending on usage Date Service Technician Name Service Performed Special Concerns Dealer Name...

Страница 20: ...20 W415 0379 B 08 03 05 NOTES...

Отзывы: