
24
W415-0810 / 06.11.09
8.0 OPTIONAL BLOWER INSTALLATION
THIS BLOWER IS NOT RECOMMENDED FOR THE 4 SIDED INSTALLATION
INSTALLATION TO BE DONE BY A QUALIFIED INSTALLER
and must be
electrically connected and grounded in accordance with local codes.In the
absence of local codes, use the current ANSI/NFPA 70 National Electrical Code
in the United States. Remove the blower from its mounting bracket and attach to
the bracket supplied with the fireplace. This bracket is found secured on the
mounting stud located at the bottom of the vent side wall.
Route a grounded 2-wire, 60Hz power cable to the
junction box. At this point, it must be strained
relieved and insulatied.
The blower bracket contains two
holes that allow the blower to be
positioned away from the intended
gas supply hole.
Position the vibration reducing pad, centred, onto the threaded stud, piercing a hole
into the pad. The blower must be able to be positioned entirely onto the pad.
Tilt the blower onto its side and slide it past the controls. Position the blower
under the clip and onto the stud. Secure with a wing nut.
Remove
the
thermal
switch
bracket from the top of the
firebox.
Remove the thermal switch from the bracket supplied in the blower
kit and install the thermal switch into the fireplace bracket. Then
replace the bracket in the location it was removed.
Connect the two ends of the unattached wires by the bracket to
the
thermal
switch.
Connect the opposite ends of the wires to the red and black leads
of
the
blower
harness.
Attach and secure the variable speed switch using the nut provided. Plug the harness cord into the recepticle.
The wire harness provided in this kit is a universal harness. When installed, ensure that any excess wire is contained,
preventing it from making contact with moving or hot objects.
Drywall dust will penetrate into the blower bearings, causing irreparable damage.
Care must be taken to prevent drywall dust from coming into
contact with the blower or its compartment. Any damage
resulting from this condition is not covered by the warranty
policy.
Because the blower is thermally activated, when turned on, it will
automatically start approximately 10 minutes after lighting the fireplace
and will run for approximately 30 - 45 minutes after the fireplace has been
turned off. Use of the fan increases the output of heat.
black
white
red
VARIABLE
SPEED
SWITCH
BLOWER
THERMAL SWITCH
VIBRATION
REDUCING PAD
WING NUT
&
LOCK WASHER
IH
O
FF
O
N
P L
O
T
I
O
L
TH
TH
TPTP
TPTP
THTH
PILOT
THERMAL SWITCH WIRES TO
BLOWER
THERMAL SWITCH
BRACKET
51.3
!
WARNING
RISK OF FIRE AND ELECTRICAL SHOCK.
TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THIS APPLIANCE.
USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH
THIS APPLIANCE. USING NON-LISTED ACCESSORIES (BLOWERS, DOORS, LOUVRES, TRIMS, GAS
COMPONENTS, VENTING COMPONENTS, ETC.) COULD RESULT IN A SAFETY HAZARD AND WILL
VOID THE WARRANTY AND CERTIFICATION.
Содержание GVF40P
Страница 35: ...35 W415 0810 06 11 09 15 0 NOTES 44 1 ...
Страница 36: ...36 W415 0810 06 11 09 44 1 ...