Minimum Enclosure Clearances
WARNING!
Use only non-combustible materials such as steel studs, cement board, ceramic tile,
marble, paint etc. When adding finishing materials to the appliance. Do not use wood or drywall.
WARNING!
You must have clear and easy access to the on/off valve AFTER the appliance is installed
and connected to the gas supply in order to safely turn off the burner.
GSS48
Appliance may be
placed at any height
including directly
on the floor with
provisions for gas and
electrical connections.
6 5/16”
(160mm)
6”
(152mm)
6”
(152mm)
16 1/2”
(419mm) (VA)
Nailing Tabs (4 per side)
6” (152mm)
(Minimum
clearance to
combustibles)
1 1/2”
(38mm)
50 3/4” (1289mm)
(Including 1/8” (3mm)
clearance per side)
47 1/2” (1207mm)
(Viewing Area (VA)
Gas and electrical lines protude from the
bottom of the appliance located on the
right side.
All material in shaded
area must be Non
Combustible. (including
framing, sheeting and
finishing materials).
NON COMBUSTIBLE
All material in shaded
area must be Non
Combustible. (including
framing, sheeting and
finishing materials).
36”
(914mm)
minimum
to ceiling.
24 3/4” (629mm)
Including 1/8”
(3mm) clearance
per side.
16 1/2”
(419mm) (VA)
36”
(914mm)
NON C
OMBUS
TIBLE