background image

8

W415-0369 / A / 03.12.03

HINGE SCREEN

C

UPPER LOUVRES:

 In-

sert the upper louvres
into the slots on both
brackets. Press the top
flange of the hood into
the four clips  located
along the top of the unit
as shown.

LOWER LOUVRES:

 At-

tach each hinge to the fire-
box with 2 screws.

HINGE SCREEN:

 Position the hinge screen into place

and with the control door open, secure to the firebox using
three screws.

The curtain mesh must be kept fully closed during opera-
tion to help prevent accidental burns from occurring.

The heater must not be used when the hood is re-

moved.

  Hook the hood over the lip of the curtain support

plate.

Remove the
backing of the
l o g o   s u p p l i e d
and place on the
screen cover, as
indicated.

LOGO PLACEMENT

HOOD

FIGURE 14

LOUVRE

HOOD

SLOT

BRACKET

A

LOUVRE INSTALLATION

LOWER  LOUVRES

(VALVE CONTROL DOOR)

B

FIGURE 15a-c

HOOD

CURTAIN

MESH

FIGURE 12

FIGURE 13

Содержание GSS36P

Страница 1: ...appliance Do not touch any electrical switch Close propane bottle or shut off gas supply Do not use any phone in your building or near the appliance Immediately call your gas supplier from a neighbou...

Страница 2: ...ace temperatures and should stay away to avoid burns or clothing ignition Supervise young children when they are in the vicinity of the fireplace Clothing or other flammable material should not be pla...

Страница 3: ...ON The bill of sale or copy will be required together with a serial number and a model number when making any warranty claims from your authorized dealer The warranty registration card must be returne...

Страница 4: ...TEST FIRED TO ASSURE ITS OPERATION AND QUAL ITY Maximum input is 40 000 BTU hr for natural gas and propane When the fireplace is installed at elevations above 2 000ft and in the absence of specific r...

Страница 5: ...a standard 20lb cylinder is available from your Napoleon Dealer 1 Move the fireplace into position and secure using the nailing tabs and or secure to the floor through the holes located at either end...

Страница 6: ...he tabs will facilitate the in stallation of either a 3 4 or a 1 finished surface thick ness The nailing tabs must not be removed FIGURE 8a b FIGURE 9 NAILING TAB INSTALLATION MANTLE CLEARANCES FIGURE...

Страница 7: ...st in the pocket on the back log 4 Position the notch located on the end of the center log 5 against the middle grate post with the other end of the log resting in the pocket of the left crossover log...

Страница 8: ...e control door open secure to the firebox using three screws The curtain mesh must be kept fully closed during opera tion to help prevent accidental burns from occurring The heater must not be used wh...

Страница 9: ...e ew hour w hour w hour w hour w hours s s s s T T T T This is a normal tempor his is a normal tempor his is a normal tempor his is a normal tempor his is a normal temporary con ary con ary con ary c...

Страница 10: ...PART 5 FINISH FOR FOR FOR FOR FOR WARRANTY WARRANTY WARRANTY WARRANTY WARRANTY REPL REPL REPL REPL REPLA A A A ACEMENT CEMENT CEMENT CEMENT CEMENT P P P P PAR AR AR AR ARTS TS TS TS TS A A A A A PHO P...

Страница 11: ...ned on check the pilot orifice for blockage replace the valve call the gas distributor Pilot goes out when the gas knob is re leased The gas valve has an interlock device which will not allow the pilo...

Страница 12: ...iances and see if pilot flame flutters dimin ishes or extinguishes especially when main burner ignites Monitor appliance supply working pressure check if supply piping size is to code Correct all unde...

Отзывы: