background image

6

W415-0369 / F / 12.10.07

FIGURE 9

FIGURE 6a-b

To install the fireplace face 
fl ush with the fi nished surface, 
position the framework to ac-
commodate the thickness of the 
fi nished surface. Bend out the 
four nailing tabs, attached on 
either side of the fi replace and 
secure to the 2x4 framing. The 
tabs will facilitate the installation 
of either a 

3

/

4

” or a 1” fi nished 

surface thickness.  

The nailing 

tabs must not be removed.

MANTEL DEPTH

15

12

14
13

4

2

16

17

8

6

0

M

A
N
T
E

L

H
E

I

G
H

T

NAILING

NAILING
 TAB

 TAB

FIGURE 8a-b

NAILING TAB INSTALLATION

MINIMUM MANTEL AND ENCLOSURE 

CLEARANCES

FIGURE 10

Combustible mantel clearance can vary according to the mantel 
depth. Use the graph to help evaluate the clearance needed.

Combustible materials may be installed fl ush with the front of the 
fi replace but must not cover any of the outer frame face-areas of 
the fi replace. Non-combustible material (brick, stone or ceramic tile) 
may protrude in these areas. 

It is not necessary to install a hearth extension with this fi replace 
system. 

When roughing in the fi replace, raise the fi replace to accommodate 
for the thickness of the fi nished fl oor materials, i.e. tile, carpeting, 
hard wood, which if not planned for will interfere with the opening 
of the lower access door and the installation of many decorative 
fl ashing accessories.

Objects placed in front of the fi replace should be kept a minimum of 
4 feet away from the front face. 

FIGURE 5

The fi replace requires a minimum enclosure height of 39 1/4”. For 
temperature requirements, the enclosure space around and above 
the fi replace must be left unobstructed. 

FIGURE 7

Содержание GSS36N

Страница 1: ...result causing property damage personal injury or death FOR YOUR SAFETY Do not store or use gasoline or other ammable vapours and liquids in the vicinity of this or any other appliance WHAT TO DO IF...

Страница 2: ...away to avoid burns or clothing ignition Keep young children and animals away when the replace is hot Clothing or other ammable material should not be placed on or near the replace Any safety screen o...

Страница 3: ...this Limited Warranty NAPOLEON may at its discretion fully discharge all obligations with respect to this warranty by refunding to the original warranted purchaser the wholesale price of any warranted...

Страница 4: ...st pressures in excess of 1 2 psig 3 5 kPa The replace must be isolated from the gas supply piping system by clos ing its individual manual shutoff valve during any pressure testing of the gas supply...

Страница 5: ...oved Assure that a continuous gas ow is at the burner before re installing the door GAS INSTALLATION If installing a propane replace the propane cylinder must always be on the exterior of such a struc...

Страница 6: ...e the clearance needed Combustible materials may be installed ush with the front of the replace but must not cover any of the outer frame face areas of the replace Non combustible material brick stone...

Страница 7: ...og 4 against the left rebox side and pulled forward to the grate The top of the log should rest in the pocket on the back log 4 Position the notch located on the end of the center log 5 against the mi...

Страница 8: ...rushing at least once a year 2 Check to see that all burner ports are burning Clean out any of the ports which may not be burning or are not burning properly 3 Check to see that the pilot ame is large...

Страница 9: ...OT INJECTOR 5 W455 0067 PROPANE GAS PILOT INJECTOR 6 W725 0028 NATURAL GAS VALVE 6 W725 0029 PROPANE GAS VALVE 7 W385 0334 NAPOLEON LOGO 8 GL 639OD LOG SET 9 W135 0183OD BACK LOG 1 10 W135 0184OD LEFT...

Страница 10: ...faulty loosen and tighten thermocouple clean thermocouple and valve connection replace thermocouple replace valve Faulty valve replace Pilot burning no gas to main burner gas knob is on HI wall switch...

Страница 11: ...ground or replace wire Remote wall switch wire is grounding Carbon is being deposited on logs or combustion chamber surfaces Flame is impinging on the logs or combustion chamber check that the logs ar...

Страница 12: ...12 W415 0369 F 12 10 07 Wolf Steel Fireplace Service History This fireplace must be serviced annually depending on usage Date Service Technician Name Service Performed Special Concerns Dealer Name...