Napoleon GI3016-N Скачать руководство пользователя страница 14

14

W415-0171 / E / 01.10.05

Gas piping is undersized.

Pilot goes out while
standing; Main burner
is in 'OFF' position.

-  turn on all gas appliances and see if pilot flame flutters,
diminishes or extinguishes, especially when main burners
ignite. Monitor supply pressure.
-  check if supply piping size is to code. Correct all under-
sized piping.

Pilot goes out when the
gas knob is released.

A  - System is not correctly
purged.

-  purge the gas line with the glass door removed.

-  fill the tank and purge the gas line with the glass door
removed.

- Out of propane gas.

-  turn up the pilot flame.

D  - Pilot flame is not engulfing
the thermopile.

-  gently twist the pilot head to improve the flame pattern
around the thermopile.

- Thermopile shorting.

-  clean thermopile and valve connection.
-  check that thermopile insulation is not frayed and ground-
ing out on the housing or the burner support.
-  replace thermopile.
-  replace valve.

- Faulty thermopile.

-  test & replace if necessary.

- Faulty valve.

-  test & replace if necessary.

C  - Pilot flame is not
large enough

Pilot burning; no gas to
main burner; gas knob
is on; wall switch is on;
heat/flame adjustment
valve is on (if so
equipped.

A - Wall switch is defective

-  connect a jumper wire across the wall switch terminals;
if the main burner lights, replace the wall switch.

- Wall switch wiring is defec-
tive.

-  disconnect switch wires from valve and connect a jumper
wire across terminals 1 and 3; if the main burner lights,
check the wires for defects and/or replace wires.

C- Main burner orifice is
plugged.

-  remove stoppage in orifice.

D - Remote gas valve operator
is defective.

-  connect a jumper wire across terminals 1 and 3; if main
burner does not light, replace gas valve.

-  fill the tank and purge the gas line with the glass door
removed.

Pilot will not light.

-  check that the wire is connected to the push button ignitor.
-  check if the push button ignitor needs tightening.
-  replace pilot assembly if the wire insulation is broken or
frayed.
-  replace pilot assembly if the ceramic insulator is cracked
or broken.
-  replace the push button ignitor.

- No spark at pilot burner

- Spark gap is incorrect

-  spark gap should be 1/16" to 1/8" from the electrode tip
and the pilot burner. Light the pilot with a match and adjust
the electrode tip to the required spark gap and proper loca-
tion.

- No gas at the pilot burner

-  check that the manual valve is turned on.
-  check the pilot orifice for blockage.
-  replace the valve.
-  call the gas distributor.

- Out of propane gas

THERMO-
PILE

P I L O T
BURNER

P I E Z O
IGNITER

1

/

16

" TO 

1

/

8

"

TROUBLE SHOOTING GUIDE

B

EFORE

 

ATTEMPTING

 

TO

 

TROUBLESHOOT

PURGE

 

YOUR

 

UNIT

 

AND

 

INITIALLY

 

LIGHT

 

THE

 

PILOT

 

AND

 

THE

 

MAIN

 

BURNER

 

WITH

 

THE

 

GLASS

 

DOOR

 

REMOVED

.

SYMPTOM

PROBLEM

TEST  SOLUTION

Содержание GI3016-N

Страница 1: ...e vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch Do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas sup plier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified ins...

Страница 2: ... vapours and liquids Do not use this fireplace if any part has been under water Immediately call a qualified service techni cian to inspect the fireplace and to replace any part of the control system and any gas control which has been under water Under no circumstances should this fireplace be modified Do not burn wood or other materials in this fire place Adults and especially children should be ...

Страница 3: ...uires the prior approval of an authorized company official Labour costs to the account of to the account of to the account of to the account of to the account of NAPOLEON NAPOLEON NAPOLEON NAPOLEON NAPOLEON are based on a predetermined rate schedule and any repair are based on a predetermined rate schedule and any repair are based on a predetermined rate schedule and any repair are based on a pred...

Страница 4: ... log The appliance off valve must be a T handle gas cock The flexible connector must not be longer than 36 inches The appliance is not approved for installation in a bedroom or bathroom unless the unit is a direct vent sealed combustion product WARNING This product must be installed by a licensed plumber or gas fitter when installed within the commonwealth of Massachusetts In absence of local code...

Страница 5: ... non combustible materials If necessary have any repair work done by a qualified person before installing the in sert Remove the existing fireplace damper or lock into an open position Using screws attach the fireplace warning tag W385 0199 to the inside of the firebox of the fireplace into which the insert is being installed The sheet metal parts of the fireplace in which the gas fireplace insert...

Страница 6: ...y again If the smoke or flame is still not drawn into the spill tube turn the unit off and check for adequate fresh air supply vent blockage or restriction If necessary consult with a qualified inspector SPILL SWITCH VENTING ACTION CHECK Levelling the insert will eliminate rocking or excessive noise when the fan is in operation Replace the securing screw to the front of the dilution plate Install ...

Страница 7: ...harcoal embers available from your Napoleon dealer 1 Place the front log onto the main burner pushing it as close as possible to the burner ports without blocking covering them The left and right spacing between the log ends and the burner ports should be equal 2 Place the back log onto the log support brackets located on the rear wall of the combustion chamber The notch situated at the lower left...

Страница 8: ...king of the logo supplied and place on the glass viewing area as indicated LOWER GLASS BRACKET LOGO 11 8 13 8 SECURING SCREW LOCATIONS LOGO PLACEMENT FLUSH GLASS FRONT KIT GI FF FLASHING SURROUND KITS GI 900 GI 909 UPPER LOUVRES Insert the back edge of the upper louvre into the upper louvre clips LOWER LOUVRES Secure the lower louvre assembly to the insert using the 4 screws supplied FLUSH LOUVRE ...

Страница 9: ...re the bay to the insert front at the top and bottom outside corners using 4 screws Note Black louvre assembly if supplied must be installed as uppers due to the high fireplace temperature Assemble the flashing and mount to the inside of the outer shell using 4 securing screws and spacers supplied as shown Hook the ornamental inlays over the spacers Both these options may be attached to the insert...

Страница 10: ...r turn the gas control knob Never use tools If the knob will not push in or turn by hand do not try to repair it Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire de partment Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building 8 Depress and hol...

Страница 11: ...l automatically start approximately 15 minutes after lighting the fireplace and will run for approxi mately 30 minutes after the fireplace has been turned off Use of the fan increases the output of heat Air drawn in through the lower louvre access door is driven up the back of the firebox and exhausted as hot air between the upper louvres Turn off the gas and electric power to the unit Remove the ...

Страница 12: ...S C W LOWER DOOR TRIM 31 GIB OIG GOLD PLATED BAY ORNAMENTAL INSETS 32 GI 778KT BRICK PANEL KIT 33 W470 0002 ENAMEL TOUCH UP AND BRUSH SPECIFY COLOUR 34 GI 700KT ZERO CLEARANCE SHELL 35 111 KT OUTSIDE AIR KIT 36 W690 0001 MILLIVOLTTHERMOSTAT 37 W660 0011 REMOTE CONTROL ADVANTAGE PLUS 38 GD 660 WALL SWITCH 20FT WIRE 39 W500 0033 V S S MOUNTING PLATE FOR WALL SWITCH 40 GI 900AB6 ANTIQUE BRASS FLASHIN...

Страница 13: ...13 W415 0171 E 01 10 05 ...

Страница 14: ...hts replace the wall switch B Wall switch wiring is defec tive disconnect switch wires from valve and connect a jumper wire across terminals 1 and 3 if the main burner lights check the wires for defects and or replace wires C Main burner orifice is plugged remove stoppage in orifice D Remote gas valve operator is defective connect a jumper wire across terminals 1 and 3 if main burner does not ligh...

Страница 15: ...ed in room head aches check for chimney blockage check that chimney is installed to building code room is in negative pressure increase fresh air supply Fireplace is spilling A Wall switch is mounted up side down B Remote wall switch is grounding C Remote wall switch wire is grounding Remote wall switch is in off position main burner comes on when gas knob is turned to ON posi tion reverse replace...

Страница 16: ...16 W415 0171 E 01 10 05 Wolf Steel Fireplace Service History This fireplace must be serviced annually depending on usage Date Service Technician Name Service Performed Special Concerns Dealer Name ...

Отзывы: