3.7 ELBOW VENT LENGTH VALUES
15.1A
FEET
INCHES MILLIMETERS
1°
0.03
0.5
12.7
15°
0.45
6.0
152.4
30°
0.9
11.0
279.4
45°
1.35
16.0
406.4
90°*
2.7
32.0
812.8
* The
fi
rst 90° offset has a zero value and is shown in the formula as - 90°
3.8 TOP EXIT HORIZONTAL TERMINATION
(H
T
) < (V
T
)
Simple venting configuration (only one 90° elbow)
See graph to determine the required vertical rise
V
T
for the
required horizontal run
H
T
.
0
2.5
(0.8)
5
(1.5)
7.5
(2.3)
10
(3.1)
12.5
(3.8)
15
(4.6)
40 (12.2)
10 (3.1)
20 (6.1)
30 (9.1)
17.5
(5.3)
20
(6.1)
35 (10.7)
REQUIRED
VERTICAL
RISE IN FEET
(METERS)
V
T
HORIZONTAL VENT RUN PLUS OFFSET IN FEET
(METERS)
H
T
For vent configurations requiring more than one 90° elbow, the following formulas apply:
Formula 1: H
T
< V
T
Formula 2: H
T
+ V
T
< 35 feet (10.7m)
Example:
V
1
= 3 FT (0.9m)
V
2
= 8 FT (2.4m)
V
T
=
V
1
+ V
2
= 3 FT (0.9m) + 8 FT (2.4m) = 11 FT (3.4m)
H
1
= 2.5 FT (0.8m)
H
2
= 2 FT (0.6m)
H
R
=
H
1
+ H
2
= 2.5 FT (0.8m) + 2 FT (0.6m) = 4.5 FT (1.4m)
H
O
= .03 (three 90° elbows - 90°) = .03 (270° - 90°) = 5.4 FT (1.7m)
H
T
=
H
R
+ H
O
= 4.5 FT (1.4m) + 5.4 FT (1.7m) = 9.9 FT (3m)
H
T
+ V
T
= 9.9 FT (3m) + 11 FT (3.4m) = 20.9 FT (6.4m)
Formula 1:
H
T
< V
T
9.9 FT (3m) < 11 FT (3.4m)
Formula 2:
H
T
+ V
T
< 35 FT (10.7m)
20.9 FT (6.4m) < 35 FT (10.7m)
Since both formulas are met, this vent configuration is acceptable.
90°
90°
90°
V
1
V
2
H
1
H
2
The shaded area within the lines represents acceptable
values for
H
T
and
V
T
16.6B
Содержание GD19-1N
Страница 40: ...W415 1351 08 29 14 40 EN SCREEN SAFETY SAFETY SCREEN FIG 4...
Страница 62: ...W415 1351 08 29 14 62 EN 43 1 22 0 SERVICE HISTORY...
Страница 63: ...W415 1351 08 29 14 63 EN 44 1 23 0 NOTES...
Страница 105: ...FR W415 1351 09 02 14 105 PROTECTION CRAN DE CRAN DE PROTECTION FIG 4...