Phone 1 (866) 820-8686 • www.napoleon.com • [email protected]

CERTIFIED TO THE CANADIAN AND AMERICAN NATIONAL STANDARDS: 

CSA 2.22 AND ANSI Z21.50 FOR VENTED DECORATIVE GAS APPLIANCES

INSTALLER: 

Leave this manual with the appliance

CONSUMER: 

Retain this manual for future reference

ADD PRODUCT CODE HERE (TRADE GOTHIC LT STD FONT)

NATURAL GAS MODELS:

PROPANE GAS MODELS:

Product Name / Code

(MUST use title from Price Book)

ADD ____ ILLUSTRATED

ADD PRODUCT IMAGE

CSA / 

INTERTEK

LOGO

SAFETY INFORMATION

- Do not store or use gasoline or other 
fl ammable vapors and liquids in the vicinity of 
this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

:

• 

Do not try to light any appliance.

• 

Do not touch any electrical switch; do not 
use any phone in your building.

• 

Immediately call your gas supplier from a 
neighbour’s phone. Follow the gas    
supplier’s  instructions.

• 

If you cannot reach your gas supplier, call 
the fi re department.

- Installation and service must be 
performed by a qualifi ed installer, service 
agency, or the supplier.

This appliance may be installed in an aftermarket, 
permanently located, manufactured home (USA 
only) or mobile home, where not prohibited by 
local codes.

This appliance is only for use with the type of gas  
indicated on the rating plate. This appliance is 
not convertible for use with other gases, unless 
a certifi ed kit is used. 

FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings exactly 
could result in serious injury, death, or 
property damage.

WARNING

!

ENGLISH 

$10.00

FOR INDOOR USE ONLY

IF INSTAL OPERATION, ADD SERIAL 

NUMBER LABEL HERE

IF SEPARATE MANUALS, ADD “PLACE 

BARCODE LABEL ON THE OWNER’S MANUAL”

INSTALLATION MANUAL 

FOR INDOOR USE ONLY

FOR USE WITH ELEVATION™ X 

MODELS ONLY

These installation instructions MUST be used in conjunction with the Elevation™ installation manual.

(Installation Option 2 illustrated)

Dynamic Heat Control™ 

air outlet opening

Содержание Dynamic Heat Control

Страница 1: ...call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a q...

Страница 2: ...gov 1 0 general information 3 2 0 installation planning 4 2 1 installation option 1 open enclosure enclosure stops short of the ceiling 5 2 2 installation option 2 front opening 5 2 3 installation op...

Страница 3: ...g comfort in front of the fireplace Increased real world efficiency as heat is moved into the room rather than retained inside the enclosure Complete flexibility in selection of finish materials Abili...

Страница 4: ...pproved appliance vent system No other items are allowed in this area De ector Clearance to Fire Sprinkler If there is a fire sprinkler system installed in close proximity to the air outlet opening of...

Страница 5: ...air outlet opening must extend around the entire perimeter or the entire front face of the enclosure where the enclosure runs from wall to wall MINIMUM AIR OUTLET OPENING DIMENSIONS EX36 EX42 Q x R 11...

Страница 6: ...opening will allow the appliance the barrier the temperatures on the surfaces above the fireplace opening and the enclosure be at cooler temperatures It will also allow the air to circulate more effec...

Страница 7: ...llation Option 1 with the addition of a hard combustible valance Minimum opening dimensions and valance dimensions must be followed Restricting air movement within the valance area will overheat the a...

Страница 8: ...sure and nishing material MINIMUM AIR OUTLET OPENING DIMENSIONS EX36 EX42 Q x R 2x 56 sq in openings minimum Q must be 3 4 L 72 Grills grates louvers or other covers are only permitted if the free are...

Страница 9: ...llation planning 3 0 appliance overview side view top view frame and de ectors not shown For plate removal see Dynamic Heat Control installation section deflector shown after installation header shiel...

Страница 10: ...not discard fasteners Before starting the Dynamic Heat Control installation remove the barrier Refer to the appliance installation manual Header shield The shipping brackets must only be removed from...

Страница 11: ...is step is crucial for your appliance to work properly If the insulation AND tray are not removed the appliance will overheat the barrier will become excessively hot and the high limit switch will con...

Страница 12: ...W415 2753 A 07 20 20 EN 12 Dynamic Heat Control installation header shield DHC deflector 5 Install the deflector using the fasteners supplied 6 Reinstall header shield using fasteners supplied...

Страница 13: ...om control board marked X4 and install plug with spade connectors to the control board Discard the original jumper plug Control Board Wire Harness Wire Harness Plug with spade connectors X4 Bracket In...

Страница 14: ...cation in the upper left hand corner of the appliance Secure high limit switch assembly with a supplied screw as shown After installing the Dynamic Heat Control system ensure appliance is clean from d...

Страница 15: ...sagging or loose insulation or framing and other combustible materials Block opening into the chase to prevent entry of blown in insulation Make sure insulation and other materials are secured Minimum...

Страница 16: ...2 51mm on the sides and bottom of the vent to combustibles is required Vertical vent sections A minimum clearance of 1 25mm all around the vent pipe on all vertical runs to com bustibles is required R...

Страница 17: ...nce manual for vent shield installation nailing tabs installation electrical installation gas installation etc Ref EX36 EX42 B 42 3 4 48 3 4 C 22 1 4 D 6 L 72 C B note The Elevation series requires a...

Страница 18: ...d 5 Opening must be centered in enclosure on appliance Dimensions represent finished sizes and where applicable should be adjusted to include finish material thickness The appliance must be installed...

Страница 19: ...rea to use non combustible facing due to close proximity to vent note Installation Option 2 illustrated note The Elevation series requires a minimum enclosure height as illustrated measured from the b...

Страница 20: ...of reach of the user Air outlet pening must not be restricted by furnishings or decor Recessed installation with Dynamic Heat Control Dynamic Heat Control front air outlet opening Dynamic Heat Control...

Страница 21: ...ce which increases the operating temperature of the appliance and around the appliance opening This is counterproductive to the benefits of heat management and in extreme cases the appliance may becom...

Страница 22: ...vailable to finish your installation The trim kit can be painted as an accent colour or to blend in with room decor The minimum air opening area must be maintained after the nishing material has been...

Страница 23: ...nge Risk of fire Maintain all specified air space clearances to combustibles Failure to comply with these instructions may cause a fire or cause the appliance to overheat Ensure all clearances i e bac...

Страница 24: ...e around the finshing flange must not project more than 4 38mm from the face of the safety barrier above the door and sides only WARNING 11 0 maximum protrusion 4 10cm Non Combustible Maximum protrusi...

Страница 25: ...t switch installed Wire harness connected to high limit switch and control board Safety Barrier installed Framing Clean all dust and debris Finish the appliance Installation of Dynamic Heat Control re...

Страница 26: ...4 40 0 Y YE EA AR RS S A A A O O O O O OF F F F F F H H H H H H H HO O O O O OM M M M ME E E E E C C CO OM M MF F FO OR RT T P PR RO OD DU UC CT TS S 7200 Route Transcanadienne Montr al Qu bec H4T 1A...