background image

3

Hearth & Home Technologies  •  DVLINEAR36 Gas Conversion Instructions  • 2569-920 Rev. B  •  5/20

14. Turn on fireplace with the green wire disconnected 

from the valve.  Note that only the pilot will ignite with 

the green wire disconnected.

15. Use  a  commercially  available,  non-corrosive  leak 

check solution to test for leaks around the pilot. Be 

sure  to  rinse  off  all  leak  check  solution  following 

testing. See Figure 4 for leak check points. 

Extinguish the pilot.  Turn fireplace OFF.

16. Reinstall burner and secure to valve plate with one 

screw.

17.  Reattach pilot assembly to the burner bracket with two 

screws.

18.   Reattach pilot shield to burner bracket with two screws.
19.  Reinstall base pan with two screws.

20. Reinstall green wire on valve.
21.  Turn fireplace on and use a commercially available, 

non-corrosive  leak  check  solution  to  test  for  leaks 

around the valve regulator.  Shut down appliance.  

Be sure to rinse off all leak check solution following 

testing.  

22. Reinstall the media by following the instructions in 

the appliance installation manual.

23. Reinstall the glass assembly.
24.  Turn on fireplace to check for proper burner flame pattern.
25. Verify that the signed and dated conversion plate has 

been added to appliance.

Verify the performance of the ignition system.

1.  Verify  pilot  sparks,  pilot  lights,  pilot  stops  sparking, 

and  the main burner turns “ON.”

2.  Turn fireplace OFF.  Verify that  both the pilot and burner 

are turned “OFF.”

3.  Repeat Step 1 above.
4.  With  burner  “ON,”  remove  green  wire  connected  to 

valve. The main burner should shut “OFF.”

5.  Reattach green wire to valve.  The main burner should 

turn back “ON.”

6.  Turn the fireplace OFF.
7.  Turn the fireplace ON.
8.  With  the  main  burner  “ON,”  remove  orange  wire 

connected to the valve. The pilot and burner should go 

out, and the pilot will start to spark.

9.  Turn fireplace “OFF“ and reattach orange wire to valve.

Propane Gas Appliance Specifications

Model

Orifice #

Shutter

Input BTU

DVLINEAR36

1.25 mm

1/8 in.

16,500

 

 

        MAXIMUM           MINIMUM 

• Inlet Gas Pressure:  ..................................................................

13.0 in. w.c.

 ......

11.0 in. w.c.

• Manifold Gas Pressure:   ...........................................................

10.0 in. w.c.

 ......N/A

• Input Rate: ....................................................See Below

When installing above 2000 feet  elevation:
•  In the USA: Reduce input rate 4% for each 1000 feet  above 2000 feet.
•   In CANADA: Input ratings are certified without a reduction of input rate for elevations up 

to 4500 feet (1370 m) above sea level. Please consult provincial and/or local authorities 

having jurisdiction for installations at elevations above 4500 feet (1370 m). 

•  See appliance installation manual for details.