Troubleshooting
Problem
Possible Causes
Solution
Low heat / Low flame
when valve turned to
high.
For Universal Liquefied Petroleum
Gas - improper lighting procedure.
For natural gas - undersized supply
line.
For both gases - improper
preheating.
Ensure lighting procedure is followed
carefully. All gas grill valves must be
in the off position when the tank valve
is turned on. Turn tank on slowly to
allow pressure to equalize. See lighting
instructions.
Pipe must be sized according to
installation code.
Preheat grill with both main burners on
high for 10 to 15 minutes.
Excessive flare-ups/
uneven heat.
Sear plates installed incorrectly.
Improper preheating.
Excessive grease and ash build on
sear plates and in drip pan.
Ensure sear plates are installed with
the holes towards the front and the
slots on the bottom. See assembly
instructions.
Preheat grill with both main burners on
high for 10 to 15 minutes.
Clean sear plates and drip pan
regularly. Do not line pan with
aluminum foil. Refer to cleaning
instructions.
Burners burn with yellow
flame, accompanied by
the smell of gas.
Possible spider web or other
debris, or improper air shutter
adjustment.
Thoroughly clean burner by removing.
See general maintenance instructions.
Open air shutter slightly according
to combustion air adjustment
instructions. (This must be done by a
qualified gas installer.)
Flames lift away from
burner, accompanied
by the smell of gas, and
possibly difficulties in
lighting.
Improper air shutter adjustment.
Close air shutter slightly according
to combustion air adjustment
instructions. (This must be done by a
qualified gas installer.)
Rear and Side burners
will not light with the
igniter, but will light with
a match.
Dead battery / or installed
incorrectly.
Loose electrode wire or switch
terminal wires.
Lifting flames on burner.
Replace with premium heavy duty
battery.
Check that electrode wire is firmly
pushed onto the terminal on the back
of the igniter. Check that the lead
wires from the module to the ignition
switch (if equipped) are firmly pushed
onto their respective terminals.
Close air shutter slightly - see previous
problem.
Main burner will not
light with the igniter, but
will light with a match.
Jet-fire outlet is dirty or clogged.
Clean jet-fire outlet with a soft bristle
brush.