W415-1345 / D / 05.01.17
EN
36
framing
!
WARNING
•
Risk of fi re. Maintain all specifi ed air space clearances to combustibles. Failure to comply with these instructions
may cause a fi re or cause the appliance to overheat. Ensure all clearances (i.e. back, side, top, vent, mantel,
front, etc.) are clearly maintained.
•
When using paint or lacquer to fi nish the mantel, the paint or lacquer must be heat resistant to prevent
discolouration
TOP OF FRONT
OPENING
8" (20.3cm) MANTEL
6" (15.2cm) MANTEL
4" (10.2cm) MANTEL
2" (5.1cm) MANTEL
12"
(30.5cm)
18"
(45.7cm)
27 15/16"
(70.9cm)
16"
(40.6cm)
14"
(35.6cm)
0
$
1
7
(
/
+
(
,
*
+
7
2
4
6
8 10 12
MANTEL DEPTH (")
12
14
16
18
20
22
(")
Combustible mantel clearance can vary according to the mantel depth. Use
the graph to help evaluate the clearance needed.
6.7
minimum mantel clearances