background image

W415-2744 / A / 11.04.19

EN

2

  

table of contents

A.

Remove the door, 
refer to installation 
instructions. Remove 
the 8 securing screws 
and lift the plate 
up and out of the 
appliance. Gasket 
may need to be 
replaced if damaged. 

This glass burner assembly is approved for use in the HDX52-1 gas appliance only. It is not approved for use as a 
stand alone appliance or in conjunction with any other appliance.

1.0 general 

information 

2

2.0 installation 

2

2.1 access 

panel 

2

2.2 burner 

assembly 

2

2.3 bulkheads 

3

2.4 media 

tray 

3

2.5 glass 

media 

4

3.0 adjustment 

5

3.1 fl 

ame 

characteristics 

5

3.2 venturi 

adjustment 

5

4.0 replacement 

parts 

6

4.1 overview 

6

4.2 

B52NG-1 glass burner 

7

2.1 access 

panel

2.2 burner 

assembly

INSIDE APPLIANCE

OUTSIDE APPLIANCE

note:

Install decorative panels before burner assembly.

A.

Attach the burner assembly to the 
fi rebox base with the screws supplied.

1.0 general information

2.0 installation

!

WARNING: 

This product can expose you to chemicals including lead and lead compounds,

which are known to the State of California to cause cancer, and chemicals including carbon 
monoxide, which are known to the State of California to cause birth defects or other reproduc-
tive harm. For more information, go to www.P65Warnings.ca.gov.

The information throughout this manual is believed to be correct at the time of printing. Wolf Steel Ltd. reserves 
the right to change or modify any information within this manual at any time without notice. Changes, other than 
editorial are denoted by a vertical line in the margin.

note:

EN

Содержание B52NG-1

Страница 1: ...Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas...

Страница 2: ...ner 7 2 1 access panel 2 2 burner assembly INSIDE APPLIANCE OUTSIDE APPLIANCE note Install decorative panels before burner assembly A Attach the burner assembly to the firebox base with the screws sup...

Страница 3: ...ead to the 1 4 bulkhead spade C Ensure the venturi tube is over the orifices before lighting D Check for gas leaks by brushing on a soap and water solution Do not use open flame E After leak test has...

Страница 4: ...roblems Do not place any media glass or vermiculite in or around the pilot opening and or on the burner ports This will interfere with the pilot operation Evenly spread the glass media onto the media...

Страница 5: ...liance has an air shutter that has been factory set open according to the chart below Regardless of venturi orientation closing the air shutter will cause a more yellow flame but can lead to carboniza...

Страница 6: ...tion Model Serial Number of appliance Installation date of appliance Part number Description of part Finish Parts part numbers and availability are subject to change without notice Parts identified as...

Страница 7: ...edia bowl assembly 8 W010 2863 Pilot assembly NG Ref Part Number Description 10 W010 3388 Pan burner assembly 11 W255 0002 12 W500 0767 Venturi support plate 13 W456 0017 Burner orifice 17 NG 14 W456...

Страница 8: ...TI IN NG G O OV VE ER R 4 40 0 Y YE EA AR RS S A A A O O O O O O OF F F F F F H H H H H H H HO O O O O OM M M M ME E E E E C C CO OM M MF F FO OR RT T P PR RO OD DU UC CT TS S 7200 Route Transcanadien...

Страница 9: ...une agence d entretien ou le fournisseur Cet appareil peut tre install dans une maison pr fabriqu e mobile d j install e demeure si les r glements locaux le permettent Cet appareil doit tre utilis uni...

Страница 10: ...2 1 panneau d acc s 2 2 assemblage de br leur INT RIEUR EXT RIEUR note Installez des panneaux d coratifs avant l assemblage du br leur A Fixez le br leur la base de la chambre de combustion l aide des...

Страница 11: ...lle C Assurez vous que les tubes de venturi sont pas dessus les injecteur avant d allumer D V rifiez pour des fuites de gaz en appliquant une solution d eau savonneuse N utilisez pas une flamme nue E...

Страница 12: ...braises vitrifi es ni vermiculite sur ou autour de l ouverture de la veilleuse ni sur les orifices du br leur Ceci interf rait avec l op ration de la pilote parpillez soigneusement les braises vitrif...

Страница 13: ...ure du volet d air a t pr r gl e en usine selon le tableau ci dessous Ind pendamment de l orientation du venturi plus le volet est ferm plus la flamme est jaune et aura tendance causer des d p ts de c...

Страница 14: ...ante Mod le et num ro de s rie de l appareil Date d installation de l appareil Num ro de la pi ce Description de la pi ce Fini Pi ces num ro des pi ces et s il soit disponible peut changer sans pr avi...

Страница 15: ...Assemblage de veilleuse GN R f No de Partie Description 10 W010 3388 Assemblage de br leur plateau 11 W255 0002 12 W500 0767 Plaque de support de venturi 13 W456 0017 Injecteur de veilleuse 17 GN 14...

Страница 16: ...US S D DE E 4 40 0 A AN NS S D D E EXISTENCE C C C C C CO O O O O ON N N N N N N N NS S S S S SA A A A A AC C CR R R R R S S L L LA A C CO ON NC CE EP PT TIO ON N D DE PR RODUITS DE CONFORT 7200 Rout...

Отзывы: