W415-1793 / A / 05.07.18
EN
28
operation
8.1 general transmitter layout
Low battery alarm
Key Lock
Room
Temperature
Light
Flame ON
Blower
Transmission
CPI mode
8.2 initializing the transmitter / battery holder for the first time
A.
Install the 4 AA batteries into the Proflame 2 battery holder, note the polarity of the batteries and insert as
indicated on the cover (+/-).
B.
Ensure the 3 position slider switch is switched to the “REMOTE” position (middle position).
C.
Press the reset/programming button, use a small object such as a paper clip in order to reach the button
marked PRG, as shown in the illustration below.
D.
The battery holder will beep 3 times to indicate that it’s ready to synchronize with the transmitter.
E.
Install the 3 AAA batteries into the transmitter, as shown in the photograph below, then press the ON
button, The battery holder will beep 4 times to indicate that the transmitter’s command is accepted.
note:
The initializing process must be completed within 10 seconds of pressing the reset/program button (PRG).
(4) AA
Batteries
TRANSMITTER
RESET/PROGRAM
BUTTON (PRG)
BATTERY HOLDER
SLIDER SWITCH
8.3 temperature display
23.3
A. Press the
on / off
key on the transmitter. The transmitter display will
show all active icons on the screen. A single “beep” from the receiver will
confi rm reception of the command.
Blue LCD Display
On / Off Key
Up / Down Arrow Key
Mode Key
Temperature Key
73
23
76
°F
68
Room Temperature
Set Temperature
76
°F
MAX
76
°F
OFF
76
°F
76
°F
76
°F
Hi
Flame Off
Flame at level 1
Flame at level 5
Flame at “Hi” level 6
76
°F
child lock
76
°F
OFF
76
°F
ON
76
°F
76
°F
68
76
°F
Hi
76
°F
OFF
76
°F
76
°F
IPI
76
°F
CPI
ON
SMART
°F
°C
ADD TITLE: TEMPERATURE DISPLAY
A. With the system in the
off
position, press the
temperature key
and the
mode key
at the same time to change from degrees F to
C.
B. Look at the LCD screen on the transmitter to verify that a C or F is
visible to the right of the room temperature display.
ADD TITLE: HAND HELD REMOTE OPERATION
The remote control has six (6) fl ame levels. With the system on and the fl ame level at the maximum, press the
down arrow key
once and it will reduce the fl ame height by one step until the fl ame is turned off.
The
up arrow key
will increase the fl ame height each time it is pressed. If the
up arrow key
is pressed while
the system is on but the fl ame is off, the fl ame will come on at the high position. A single “beep” will confi rm
reception of the command.
ADD TITLE: FLAME HEIGHT
Blue LCD Display
On / Off Key
Up / Down Arrow Key
Mode Key
Temperature Key
73
23
76
°F
68
Room Temperature
Set Temperature
76
°F
MAX
76
°F
OFF
76
°F
76
°F
76
°F
Hi
Flame Off
Flame at level 1
Flame at level 5
Flame at “Hi” level 6
76
°F
child lock
76
°F
OFF
76
°F
ON
76
°F
76
°F
68
76
°F
Hi
76
°F
OFF
76
°F
76
°F
IPI
76
°F
CPI
ON
SMART
°F
°C
If the appliance is equipped with a hot air circulating fan, the speed of
the fan can be controlled by the remote system. The fan speed can be
adjusted through six (6) speeds.
A. Use the
mode key
to guide you to the fan control icon.
B. Use the
up/down arrow keys
to turn
on/off
or adjust the fan
speed. A single “beep” will confi rm reception of the command.
ADD TITLE: FAN SPEED
Blue LCD Display
On / Off Key
Up / Down Arrow Key
Mode Key
Temperature Key
73
23
76
°F
68
Room Temperature
Set Temperature
76
°F
MAX
76
°F
OFF
76
°F
76
°F
76
°F
Hi
Flame Off
Flame at level 1
Flame at level 5
Flame at “Hi” level 6
76
°F
child lock
76
°F
OFF
76
°F
ON
76
°F
76
°F
68
76
°F
Hi
76
°F
OFF
76
°F
76
°F
IPI
76
°F
CPI
ON
SMART
°F
°C
ADD TITLE: CHILD PROOF FUNCTION
This function will lock the keys to avoid unsupervised operation.
A. Press the
mode and up keys
at the same time.
B. To de-activate this function, press the
mode and up keys
at the same time.
Blue LCD Display
On / Off Key
Up / Down Arrow Key
Mode Key
Temperature Key
73
23
76
°F
68
Room Temperature
Set Temperature
76
°F
MAX
76
°F
OFF
76
°F
76
°F
76
°F
Hi
Flame Off
Flame at level 1
Flame at level 5
Flame at “Hi” level 6
76
°F
child lock
76
°F
OFF
76
°F
ON
76
°F
76
°F
68
76
°F
Hi
76
°F
OFF
76
°F
76
°F
IPI
76
°F
CPI
ON
SMART
°F
°C
Blue LCD Display
On / Off Key
Up / Down Arrow Key
Mode Key
Temperature Key
73
23
76
°F
68
Room Temperature
Set Temperature
76
°F
MAX
76
°F
OFF
76
°F
76
°F
76
°F
Hi
Flame Off
Flame at level 1
Flame at level 5
Flame at “Hi” level 6
76
°F
child lock
76
°F
OFF
76
°F
ON
76
°F
76
°F
68
76
°F
Hi
76
°F
OFF
76
°F
76
°F
IPI
76
°F
CPI
ON
SMART
°F
°C
Blue LCD Display
On / Off Key
Up / Down Arrow Key
Mode Key
Temperature Key
73
23
76
°F
68
Room Temperature
Set Temperature
76
°F
MAX
76
°F
OFF
76
°F
76
°F
76
°F
Hi
Flame Off
Flame at level 1
Flame at level 5
Flame at “Hi” level 6
76
°F
child lock
76
°F
OFF
76
°F
ON
76
°F
76
°F
68
76
°F
Hi
76
°F
OFF
76
°F
76
°F
IPI
76
°F
CPI
ON
SMART
°F
°C
Blue LCD Display
On / Off Key
Up / Down Arrow Key
Mode Key
Temperature Key
73
23
76
°F
68
Room Temperature
Set Temperature
76
°F
MAX
76
°F
OFF
76
°F
76
°F
76
°F
Hi
Flame Off
Flame at level 1
Flame at level 5
Flame at “Hi” level 6
76
°F
child lock
76
°F
OFF
76
°F
ON
76
°F
76
°F
68
76
°F
Hi
76
°F
OFF
76
°F
76
°F
IPI
76
°F
CPI
ON
SMART
°F
°C
When the desired blower speed is selected, the blower will automatically come on 5 minutes after the main
burner has been turned on and remain on twelve minutes after it has been turned off.
note:
ADD TITLE: NIGHT LIGHT
T
he auxiliary function controls the
AUX
power outlet on the control module
which controls the
Night Light™
.
A. Use the
mode key
to guide you to the
AUX
icon.
B. Pressing the
up arrow key
will activate the
Night Light™
.
C. Pressing the
down arrow key
will turn the
Night Light™
off. A single
“beep” will confi rm the reception of the command.
Blue LCD Display
On / Off Key
Up / Down Arrow Key
Mode Key
Temperature Key
73
23
76
°F
68
Room Temperature
Set Temperature
76
°F
MAX
76
°F
OFF
76
°F
76
°F
76
°F
Hi
Flame Off
Flame at level 1
Flame at level 5
Flame at “Hi” level 6
76
°F
child lock
76
°F
OFF
76
°F
ON
76
°F
76
°F
68
76
°F
Hi
76
°F
OFF
76
°F
76
°F
IPI
76
°F
CPI
ON
SMART
°F
°C
The life span of the remote batteries depends on various factors: quality of the batteries,
the number of ignitions, etc.
When the transmitter batteries are low, a battery icon will appear on the LCD display
before all battery power is lost. When the batteries are replaced, this icon will disappear.
When the receiver batteries are low, no “beep” will be emitted from the receiver when
it receives an
on/off
command. This in an alert for the receiver that there’s low battery.
When the batteries are replaced the “beep” will be emitted from the receiver when the
on/off key
is pressed.
If the batteries of the receiver or transmitter are low, the appliance can be turned on manually by sliding the
three position slider switch on the receiver to the
on
position. This will bypass the remote control feature and the
appliance main burner will come on if the gas valve is in the
on
position.
ADD TITLE: IN THE EVENT OF A POWER FAILURE
If the receiver is equipped with batteries they will enable fl ame height control or
on/off
function to control the
appliance during a power failure. Blower and
Night Light™
operation is not possible. Refer to
“appliance
operation”
section when communications between receiver and transmitter have been lost. The receiver will
emit a “beep” sound to confi rm programming has been successful once power is restored. During a power
failure, if the appliance was on, the fl ame height will stay at the setting prior to the failure. If off when the failure
occurs and then turned on, the fl ame height will come on at
“Hi”
. The fl ame height can then be controlled by the
remote.
ADD TITLE: LOW BATTERY / MANUAL BYPASS
ADD TITLE: Night Light Dimmer Control
Blue LCD Display
On / Off Key
Up / Down Arrow Key
Mode Key
Temperature Key
73
23
76
°F
68
Room Temperature
Set Temperature
76
°F
MAX
76
°F
OFF
76
°F
76
°F
76
°F
Hi
Flame Off
Flame at level 1
Flame at level 5
Flame at “Hi” level 6
76
°F
child lock
76
°F
OFF
76
°F
ON
76
°F
76
°F
68
76
°F
Hi
76
°F
OFF
76
°F
76
°F
IPI
76
°F
CPI
ON
SMART
°F
°C
The auxiliary function controls the
Night Light™
with dimmable control.
A. Use the
mode key
to guide you to the
Night Light™
icon.
B. The intensity of the output can be adjusted through 6 levels.
Use the
up/down arrow keys
to adjust the output level. A single beep
will confi rm reception of the command.
ADD TITLE: CONTINUOUS PILOT / INTERMITTENT PILOT (CPI / IPI) SELECTION
A. When the transmitter is in the
off
position, use the
mode key
to guide
you to the CPI mode icon.
B. Press the
up/down
to switch between
IPI and CPI modes
. A single
beep will confi rm reception of the command.
Blue LCD Display
On / Off Key
Up / Down Arrow Key
Mode Key
Temperature Key
73
23
76
°F
68
Room Temperature
Set Temperature
76
°F
MAX
76
°F
OFF
76
°F
76
°F
76
°F
Hi
Flame Off
Flame at level 1
Flame at level 5
Flame at “Hi” level 6
76
°F
child lock
76
°F
OFF
76
°F
ON
76
°F
76
°F
68
76
°F
Hi
76
°F
OFF
76
°F
76
°F
IPI
76
°F
CPI
ON
SMART
°F
°C
Blue LCD Display
On / Off Key
Up / Down Arrow Key
Mode Key
Temperature Key
73
23
76
°F
68
Room Temperature
Set Temperature
76
°F
MAX
76
°F
OFF
76
°F
76
°F
76
°F
Hi
Flame Off
Flame at level 1
Flame at level 5
Flame at “Hi” level 6
76
°F
child lock
76
°F
OFF
76
°F
ON
76
°F
76
°F
68
76
°F
Hi
76
°F
OFF
76
°F
76
°F
IPI
76
°F
CPI
ON
SMART
°F
°C
Blue LCD Display
On / Off Key
Up / Down Arrow Key
Mode Key
Temperature Key
73
23
76
°F
68
Room Temperature
Set Temperature
76
°F
MAX
76
°F
OFF
76
°F
76
°F
76
°F
Hi
Flame Off
Flame at level 1
Flame at level 5
Flame at “Hi” level 6
76
°F
child lock
76
°F
OFF
76
°F
ON
76
°F
76
°F
68
76
°F
Hi
76
°F
OFF
76
°F
76
°F
IPI
76
°F
CPI
ON
SMART
°F
°C
If the appliance is equipped with a CPI/IPI toggle switch, set the CPI/IPI
to CPI position to enable remote CPI operation. If the switch is set to IPI
then it will only work in IPI regardless of what is set on the remote control
handset.
note:
Содержание Ascent X 70 Series