W415-1326 / 05.23.14
24
EN
4.8 MOBILE HOME INSTALLATION
4.9 MINIMUM CLEARANCE TO COMBUSTIBLES
As long as clearance to combustibles is kept within required distances, the most desirable and bene
fi
cial
location for an appliance is in the centre of a building, thereby allowing the most ef
fi
cient use of the heat
created. The location of windows, doors and the traf
fi
c
fl
ow in the room where the appliance is to be located
should be considered. If possible, you should choose a location where the vent will pass through the house
without cutting a
fl
oor or roof joist.
MAINTAIN THESE MINIMUM CLEARANCES TO COMBUSTIBLES:
A.
4" (1219mm)
B.
2" (51mm)*
C.
2" (51mm)
Appliance top to ceiling
48" (1219mm)
Horizontal
vent
Sides and bottom**
1" (25mm)
Top
2"
(51mm)
Vertical Vent
All
sides 1"
(25mm)
* At a distance of 2" (51mm) from the wall, access to the blower switch, on-off switch or the blower power cord
may not be practical. A minimum of 5" (127mm) will be required in order to install the blower.
** HORIZONTAL VENT SECTIONS:
A minimum clearance of 1" (25mm) at the bottom and sides and 2"
(51mm) at the top of the vent pipe in all horizontal runs to combustibles is required. Use
fi
restop spacer W585-
0267 (supplied).
** VERTICAL VENT SECTIONS:
A minimum of 1" (25mm) all around the vent pipe on all vertical runs to
combustibles is required. Use
fi
restop spacer W500-0097 (not supplied).
29.6
This Mobile/Manufactured Home Listed appliance comes factory equipped with a means to secure the unit. Built
in appliances are equipped with 1/4” diameter holes located in the front left and right corners of the base. Use #10
hex head screws, inserted through the holes in the base to secure. For free standing products contact your local
authorized dealer / distributor for the appropriate securing kit. For mobile home installations, the appliance must be
fastened in place. It is recommended that the appliance be secured in all installations. Always turn off the pilot and
the fuel supply at the source, prior to moving the mobile home. After moving the mobile home and prior to lighting
the appliance, ensure that the logs are positioned correctly.
This appliance is certi
fi
ed to be installed in an aftermarket permanently located, manufactured (mobile)
home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certi
fi
ed kit is used.
Conversion Kits
This appliance is
fi
eld convertible between Natural Gas (NG) and Propane (LP).
To convert from one gas to another consult your Authorized dealer/distributor.
Содержание Arlington GDS20N
Страница 42: ...W415 1326 05 23 14 42 EN 16 0 SERVICE HISTORY 43 1...
Страница 43: ...W415 1326 05 23 14 43 EN 17 0 NOTES 44 1...
Страница 86: ...16 0 NOTES 44 1 FR W415 1326 05 26 14 86...
Страница 87: ...44 1 FR W415 1326 05 26 14 87...