EN
W415-2212 / G / 02.10.20
17
installation
BLACK (L1)
WHITE (N)
YELLOW (N1)
YELLOW (N2)
GREEN (G)
(G)
Jumper
Jumper
(N)
(L1)
RED (L2)
L
W
L
L
R
Use 2 jumper wires
to connect
N to N1 and N2.
4
6
1
1
-
:
1
0
8
&
3
+
6
/
$
5
*
0
/
'
*
3
&
1
-
"
$
&
GREEN (G)
GREEN (G)
RED (L2)
BLACK (L1)
WHITE (N)
YELLOW (N2)
YELLOW (N1)
BLACK (L1)
JUMPER
JUMPER
WHITE (N)
120V
There are 5 wires from the appliance junction that connect to 120V power supply (breaker panel): 1 white (neu-
tral), 2 yellow (heater & neutral), 1 black (power L1), and 1 green (ground). Do
NOT
connect red wire to power
supply (breaker panel).
note:
4.5.2 NEFL42 / 50 / 60 / 74 CHD 120V hardwiring
Leave enough wire so that the appliance can be removed from the enclosure for ease of disconnecting the
power supply if the appliance needs to be serviced.
note:
1. Remove the securing screws from the electrical cover plate located on the rear left side of the appliance.
2. Loosen the securing screws from the terminal block to remove the cord from the terminal block.
3. KEEP 2 JUMPER WIRES IN THE TERMINAL BLOCK.
4. Add an electrical box connector and feed the supply wires through the 7/8” (22mm) hole from the terminal
block.
5. Insert White (N) wire from power supply to the designated (N) slots in the terminal block. Secure by tightening
the screws on the (N) slots.
ENSURE JUMPER WIRES ARE SECURED.
6. Repeat step 5 with Black (L1) and Green (G), securing them to their designated slots in the terminal block.
7. Re-install cover plate.