W415-1707 / B / 06.04.18
EN
34
venting installation
Type 1 (x2)
The vent shield is telescopic and must be adjusted to shield at least the first 15” of vertical vent always used.
FOR SEE-THRU APPLIANCES, REPEAT STEPS WITH THE OPPOSITE SIDE. (Two vent shields required.)
Fig. 1
Fig. 2
Fig. 3
1. Unscrew the fasteners on the vent shield assembly. DO NOT DISCARD FASTENERS
(Fig. 1
).
2. Adjust vent shield to a minimum of 15”
(Fig. 2)
.
3. Use the fasteners in step 1 to hold the new vent shield height
(Fig. 3)
.
4. Unscrew the fasteners as shown in Figure 4. DO NOT DISCARD FASTENERS.
5. Use the fasteners in step 4 to secure the vent shield to the appliance
(Fig. 5)
.
6. Secure the vent shield with two fasteners (supplied) to the front upper frame
(Fig. 6)
.
note:
5.6 vent shield installation
Fig. 4
Fig. 5
Fig. 6
SEE-THRU EXAMPLE
Front of
appliance
For ease of installation, the front frame can be removed. The front frame must be
reinstalled prior to installing the nailing tabs.
important: