StarLink™ Connect SLE-LTEV-C / SLE-LTEV-Z  Alarm Communicators -- Installation Instructions 

 

 

SLE-LTEV-Z 

- Network Compatible LTE 

(Verizon) alarm capture radio communi-
cator, SIM card included.  Includes the 

SLE-ZWAVE-MOD

 Z-Wave module. 

 

White plastic enclosure.   

 

For Commercial Burglary installations, under the armed con-
dition, any loss of communication must be treated as a Bur-
glary Alarm at the Central Station. 

 

ADDITIONAL COMPONENTS 

  In addition to the models listed above, the following sub-

assemblies are available: 

 

SLE-WIFI-MODULE

 - Allows your Napco iBridge

®

 or Star-

Link

 device to connect to the Internet by means of a 

wireless (Wi-Fi) link, eliminating a wired Ethernet cable 
connection.   

SLE-ZWAVE-MOD

 - Included with the 

SLE-LTEV-Z 

radio, 

the Z-Wave module (PC board) allows your Napco 
iBridge

®

 or StarLink

 device to connect to your Z-Wave 

devices.   

SLE-DLCBL

 - Download Cable, 6 feet. 

SLE-ANTEXT30

 - Extended antenna with 30 feet of cable. 

SLE-ANTEXT50

 - Extended antenna with 50 feet of cable. 

SLE-ANTEXT75

 - Extended antenna with 75 feet of cable. 

  (Any suitable external cellular antenna is permitted by 

UL).  Always follow the manufacturer's installation in-
structions.  

Note:

  Antennas are not Listed by UL.   

 

SPECIFICATIONS

 

 The 

following 

specifications 

apply to all StarLink radio mod-

els unless otherwise stated: 

 

 

Electrical Ratings for +12V (both models powered by the 
control panel) 



Input Voltage:  10-15VDC (regulated power-limited output 
from control panel).  Do NOT connect to full-wave recti-
fied (FWR) power.   



Input Current:  

SLE-LTEV-C

 standby current:  126mA (135mA with 

telco EOLR) 



For Z-Wave add 10mA; for Wi-Fi add 45mA 

SLE-LTEV-Z

 standby current:  135mA (145mA with 

telco EOLR) 



Transmission current (both models):  Add 135mA. 

 

WI2307CLF  6/19 

333 Bayview Avenue Amityville, New York 11701 

For Sales and Repairs, (800) 645-9445 

For Technical Service, (800) 645-9440 or visit us at 

http://tech.napcosecurity.com/ 

(Note:  Technical Service is for security professionals only)

 

Publicly traded on NASDAQ      Symbol: NSSC 

© NAPCO 2019 

OVERVIEW 

 The 

StarLink

 Connect models 

SLE-LTEV-C

 and 

SLE-

LTEV-Z 

are multi-function Commercial Burglary and Resi-

dential Fire alarm radio communicators and supervised sys-
tem interface modules.  They provide several options to the 
home owner: 

 

1. A monitoring path to a central station through a digital 

LTE (Verizon) radio and optionally through a TCP/IP 
network to the Internet using a hardwired Ethernet con-
nection or optional Wi-Fi adapter (Wi-Fi not used for 
Commercial Burglary); 

 

2. Notification alerts of alarm system changes to a mobile 

device.  Notifications use 

iBridge Messenger 

SMS text 

messaging and/or emails to inform the user and/or deal-
er of system state changes.  For this release, these noti-
fications are enabled in the 

iBridge Connected Home 

Services 

website at 

http://ibridge.napconoc2.com

 
 

 

NAPCO control panels are programmed in the tradition-
al way using PCD-Windows Quickloader software.  The 

StarLink Connect

 application is available on the en-

closed CD or can be downloaded from the Napco Tech-
nical Library at 

http://tech.napcosecurity.com/

.   

 

3. Allows users to control Z-WAVE devices in several 

ways: 

a.  Through the use of a mobile device app; 

 

b. Through Z-Wave Schedules; 

 

c. Through Z-Wave Scenes; 

 

  If required, mount the unit to a single-, dual-, or three-gang 

electrical box and route the wires through the back knock-
out(s), or as specified by local codes.  

See WI2140 for pro-

gramming instructions 

(all manuals are available for 

download at 

http://tech.napcosecurity.com/

). 

 

  StarLink SLE Series radios use proprietary data-capture 

technology that captures the alarm report from the control 
panel and transmits the alarm signals to the SLE Control 
Center (the Napco "NOC"); the alarm signals are then for-
warded to ANY central station via Contact ID or 4/2 via 
DACT from the NOC or Sur-Gard System II, Sur-Gard Sys-
tem V, Bosch D6100IPV6 or Bosch D6600 Receiver (with 
ITS-D6686 Ethernet Adapter) via TCP/IP using standard 
line security.  The SLE Control Center reports a trouble sig-
nal in the event that the network does not receive the ex-
pected supervision signal from the wireless communicator.  
In addition, both StarLink radio models can be powered di-
rectly from the control panel.   

 

The StarLink radio model names are as follows: 

 

SLE-LTEV-C 

- Network Compatible LTE (Verizon) alarm 

capture radio communicator, SIM card included.  White 
plastic enclosure.   

StarLink

 Connect LTE Series  

SLE-LTEV-C / SLE-LTEV-Z 

Multi-Function Alarm Communicators  

INSTALLATION INSTRUCTIONS 

AGENCY LISTINGS 



UL 1610 Standard For Central-Station Burglar-Alarm Units 



UL 985 Standard For Household Fire Warning System Units 

LTEV models are Verizon

®

 Network Certified 

Содержание StarLink Connect LTE Series

Страница 1: ...home owner 1 A monitoring path to a central station through a digital LTE Verizon radio and optionally through a TCP IP network to the Internet using a hardwired Ethernet con nection or optional Wi Fi...

Страница 2: ...For this in put to report to a central station the StarLink radio must be configured with the central station telephone number and correct reporting formats and codes TB7 IN 2 See TB9 below TB8 GND Co...

Страница 3: ...s off No network cable detected When DS14 is flashing rapidly No IP connection occurs just after power on while trying to obtain an IP address therefore has priority over any other green flashing LEDs...

Страница 4: ...ides a minimum of 2 blinks c Once a location has been selected based on signal coverage permanently secure the unit using 8 screws not supplied in the two mounting holes When DS15 is flashing slowly 1...

Страница 5: ...persons STEP 3 WIRING 22 gauge wire may be used if mounted up to 50 feet from the control panel and 18 gauge wire should be used for up to 100 feet Reference the wiring diagrams further in this manual...

Страница 6: ...dio supervision timer is restarted For example if a status change is sent the next regular su pervision transmission will occur at the interval determined by your rate plan For radio models powered by...

Страница 7: ...50 Burg Perimeter Alarm E131 Burg Interior Alarm E132 Keypad Holdup Alarm ambush E121 Keypad Panic Alarm E123 Keypad Emergency Alarm E140 Opening E401 Closing R401 A C Trouble E301 Tel 1 Fail E351 Fir...

Страница 8: ...TEL LINE PHONE 2 2K CONTROL PANEL HOUSING STARLINK RADIO HOUSING StarLink Radio Terminals 9 10 11 REMOTE BUS BLK GRN 12 YEL RED Control Panel PC Board un polarized un polarized 9 10 11 REMOTE BUS BLK...

Отзывы: