WI1370 XP-400 Installation Instructions  

Arming/Disarming with a Keyfob  

The system can be armed by pressing the 

K

 

key, and disarmed by pressing the 

L

 key on 

the Keyfob. Zones programmed as 

Exit/Entry 

Follower Zones

 can be bypassed when the 

M

 

or 

N

 keys on the Keyfob have been 

programmed for 

Interior

 

[81-82]. Zones 

programmed as Home

/Away with Delay Zones

 

can be armed regardless of the state of the 

Exit/

Entry Zones

 when the 

M

 or 

N

 keys on the 

Keyfob have been programmed for 

Full Set 

[81-

82].  To arm the system with all zones protected, 
press the 

K

 key.  Press and hold the 

M

 or 

N

 key for 1.5s to fully set the system (The 

LED on the Keyfob indicates the Keyfob is 
tranmitting the signal).  Program 

Keyfob/

Keyswitch Chirp

 [23-4] for an audible indication 

of system arming and disarming. 

 

Arming Instant with a Keyfob  

The panel can be ARMED INSTANT when the 

M

 or 

N

 keys on the Keyfob have been 

programmed for  

Instant 

[81-82]. To arm the 

system with Instant protection press the 

K

 

key, then press and hold the 

M

 or 

N

 key for 

1.5s to arm the panel with INSTANT protection.

 

 

Arming/Disarming with a Keyswitch 

The system can be armed/disarmed by using a 
momentary Keyswitch wired to 

Zone 4

Program 

Keyfob/Keyswitch Chirp 

[23-4] for an audible 

indication of system arming and disarming. 

 

 

 
 
 
Disarming (System OFF) 

After entering the premises through an Exit/
Entry Zone, the keypad will sound the Entry 
Delay Tone.  Enter a valid Arm/Disarm code.  If 
a valid Arm/Disarm code is entered, the keypad 
will beep 6 times, indicating the panel has been 
disarmed.  The red Armed LED will go out.  If an 
incorrect Arm/Disarm Code is entered, the 
keypad will sound a 1-second tone, indicating 
incorrect entry.  Press the 

B

 key and re-enter 

the code.  
 

Disarming after an Alarm 

(Alarm Memory) 

The armed LED and the zone(s) that caused the 
alarm will be be flashing.  Disarm the panel.  
The system is currently not detecting zone faults 
or displaying system trouble.  The zone(s) that 
caused the alarm will continue to flash. The 

Ready and 

H

SYSTEM TRBL LEDs are out 

indicating: 
 

The system is displaying 

Alarm Memory

 
Press the 

B

 key to clear Alarm Memory. 

 

Bypassing  

 
Automatic Bypassing 
Home/Away with Delay  Zones 

This zone type has the following operation 
depending on whether an 

Exit/Entry Zone 

has 

been violated during the 

Exit Delay 

time. 

 

Home   

Exit/Entry Zone

  is not violated 

 

Zones selected as Home/Away with Delay 
Zones

 will be bypassed automatically.   

 
Away with Delay 

Exit/Entry Zone is violated  

Zones selected as Home/Away with Delay 
Zones

 will have a fixed 20-second entry 

delay when violated before an 

Exit/Entry 

Zone

 

N

OTE

:

 

Faulted Keyswitch or silent 24 hour zones normally do not 
display at the keypad.  If a silent 24 hour zone or 
Keyswitch is faulted at the time of arming the faulted zone 
will display only while the priority sound is ON. 

Содержание RPXP4GT

Страница 1: ...XP 400 RPXP4GT keypad Control Panel Communicator Installation Instructions WI1370 1 05 NAPCO 2005...

Страница 2: ...Cut Detection Answering Machine Override Second Call Communicator 2 Telephone Numbers Backup Reporting Pager Format Point ID Format Individually Report 4 Users Opening after Alarm Report Cancel Code C...

Страница 3: ...12V 4 AH Rechargeable Change Battery every 5 years or as required Maximum Charging Current 165 mA Maximum Input Current 2 58 A Loop Characteristics Loop Voltage 5 Volts Loop Current Zones 1 2 0 9 mA...

Страница 4: ...ification HARMONIZED STANDARDS EN50081 1 and EN50082 1 EC DIRECTIVES 89 336 EEC Electromagnetic Compatibility Directive Optional Accessories Wireless Receiver Window Door Transmitter Key Fob Transmitt...

Страница 5: ...ng PCPreset For Site Initiated Downloaded see Auto Download ID Number 93 Local Downloading Wire as shown in Figure 1 Use the power up or A6 method of establishing a connection The power up method is r...

Страница 6: ...as shown in the wiring diagram in the back of this manual WARNING The FCC restricts the use of this equipment on certain telephone lines Read the FCC statement on the back of this manual to ensure co...

Страница 7: ...ode when the Bell or PGM is ON Bell and PGM will turn OFF Keypad LEDs W ARMED LED DEFINITION Armed ON Instant Mode Rapid Flash Zone in Alarm Flashing X READY LED DEFINITION Ready to be Armed ON Zone f...

Страница 8: ...entering the premises through an Exit Entry Zone the keypad will sound the Entry Delay Tone Enter a valid Arm Disarm code If a valid Arm Disarm code is entered the keypad will beep 6 times indicating...

Страница 9: ...sing a zone Disarmed only Press the C key then the number of the zone to be unbypassed Group Bypass Press C C to Bypass all Exit Entry Follower Zones 02 or Home Away Zones 01 only if the system is pro...

Страница 10: ...command to bypass all Exit Entry Follower Zones or Home Away Zones only if the system is programmed exclusively for Home Away with Delay zones A4 Instant Enter this command before or after arming to...

Страница 11: ...eypad will sound a short beep for transmitters with signal strengths of 3 or less Zone Features 00 Exit Entry Zones Delay allows exit and entry through an Exit Entry Zone after the system is armed wit...

Страница 12: ...s restored while the control panel is still armed the zone will automatically be unbypassed and any subsequent violations of the zone will cause an alarm condition 04 24 Hour Protection A zone that pr...

Страница 13: ...am the interval in days between Test Timer reports Test Timer Interval may be programmed from 1 to 255 days 15 Line Cut Time to Fail Enable this feature by programming the delay time required to decla...

Страница 14: ...winger Shutdown Automatically disables armed zones with excessive alarm restores swingers Non 24 Hour Protection zones allows only 3 alarms and 2 restores per zone per arming before the zone is disabl...

Страница 15: ...ion is not permitted for UL installations Telephone Number 1 Programming 30 Subscriber ID Number For 4 2 format enter a 4 digit number If 3 1 format is required enter a 3 digit number then press the i...

Страница 16: ...ager Format Selected Pager PIN Number Program if a PIN number is required by the paging system The digits in Telephone Number 2 will be added on to telephone number 1 and or telephone number 3 allowin...

Страница 17: ...ne detection can be disabled by programming No Dial Tone Detection 46 1 To program any additional delay enter a D where required in the phone number 42 Receiver Format Telco 2 Select the format that w...

Страница 18: ...tore code is the zone number of the restored zone For example if the Zone Restore Code 62 is programmed to E the restore code for that zone would be E4 4 2 format 62 2 Trouble Code Conditional Closing...

Страница 19: ...al Closing Telco 3 see 67 1 3 Reserved 4 Reserved Wireless Up to two receivers can be wired to the XP 400 Each wireless transmitter can be mapped to a zone Only 1 wireless device is permitted per zone...

Страница 20: ...c alarm when the M or N buttons on the Keyfob are pressed Additional programming required Keypad Panic GG 20 3 Panic Report to Telco 1 36 2 and or Telco 3 56 3 Audible Panic Optional 21 1 2 AUX Progra...

Страница 21: ...t 91 2 Answering Machine Override Using the downloading computer call the panel When the operator has determined that the panel has received 1 2 rings pressing the u key will cause the downloading com...

Страница 22: ...nnot be programmed from User Program Mode 96 Dealer Options 1 1 Dealer Code Lockout Program to prevent the Dealer Code from changing with a panel default 2 User 1 Code Lockout If programmed the User 1...

Страница 23: ...will beep once every 10 seconds The keypad will continue to beep until the reset button is pressed or the trouble has been acknowledged by pressing the i key System Trouble Reporting The following sys...

Страница 24: ...EOL2 2K resistor must be installed 3 Rcvr Fail to Respond Rcvr Tamper The receiver is not responding to the panel The red LED on the receiver should be flashing refer to WI848 The cover is off the rec...

Страница 25: ...t loop current flowing through the Bell circuit for supervision To eliminate this cut resistor R26 which is located directly above Terminal 9 just below the heat sink 5 Where are the fuses The control...

Страница 26: ...1 and point 2 is jumped out If using internal reed make sure J1 is cut and both Point 1 and Point 2 terminals are jumped out 10 Keypad LEDs Flicker The Keypad is not receiving a POLL from the Panel Ch...

Страница 27: ...esistors AUX POWER OUTPUT 10 12 5 VDC XP 400 WIRING DIAGRAM REFER TO INSTALLATION INSTRUCTIONS WI1371 RESIDENTIAL BURG 4 HOUR STANDBY COMBINED STANDBY 350 mA BELL 2 0 AMP 1 Z NOT USED Normally Open Zo...

Страница 28: ...sting and due to but not limited to any or all of the following criminal tampering electrical or communications disruption it is possible for the system to fail to perform as expected NAPCO does not r...

Отзывы: