background image

THE LIBRA-DXK4RF SERIES KEYPAD  

 
DESCRIPTION 

The LIBRA-DXK4RF series keypad is a multi-segment LCD digital keypad that is compatible with the LIBRA LIB-
P432EX, LIB-P432EXT, LIB-P432EXT-230 control panels.  Refer to User Guide OI349 for keypad operation 
instructions.  

While the LIBRA-DXK4RF series keypads may be used to fully program the control panel, the 

GEM-DXRP1 or GEM-DXK1 keypads, with their easy to read two-line LCD displays, provide the optimum in 
ease of keypad programming.  Note:  

Do not mix "RP" series keypads with "K Series" keypads within one system. 

 

The wireless system comprises a compatible LIBRA LIB-P432EX series control panel, at least one LIBRA-RECV re-
ceiver and one or more companion LIBRA-Series transmitters.  Built inside the LIBRA-DXK4RF series keypad is a re-
ceiver to save space and simplify installation.  The transmitters may be wireless smoke detectors, space-protection de-
vices, window/door sensors, or other devices that report zone status and supervision information to the receiver with-
out the use of wires. 

 

The integral receiver inside the keypad will accommodate up to 32 wireless points.  The receiver is connected to the 
control panel's 4-wire bus through the same 4 wires as the keypad.  The receiver monitors each transmitter, updating 
transmitter status as reports are received, and conveys this information to the control panel.  Also monitored is the 
elapsed time since the last report from each transmitter.  If no report is received within a programmed time, a Supervi-
sory Failure will result. 

 
COMPATIBLE CONTROL PANELS 

See WI1752 for installation and programming instructions with the GEM-P816, GEM-P1632, GEM-P3200 and GEM-
P9600 control panels.   

 
SPECIFICATIONS 

Operating Voltage:  12VDC (supplied by panel) 
Current Drain:  75 mA Standby 
     

Note:  

Subtract keypad current from combined auxiliary current of the control panel. 

Operating Temperature:  0° C to 49° C 
Storage Temperature:  20° C to + 85° C 
Power Requirements:  12VDC, 75mA (supplied by panel) 
Antenna:  ¼-wave (external wire), and internal antennas. 
Dimensions:  5 7/8" x 4 3/8" x 1" (WxHxD) 

 
ORDERING INFORMATION 

Note:  

Any of the following Napco wireless transmitters may be used with the LIBRA-RECV Series Receivers.  Bat-

teries are included with all transmitters. 

 

LIBRA-TRANS433 - 

Window/Door Sensor.  This supervised, two-point transmitter provides an internal magnetic reed 

switch and/or terminals for two external normally-closed devices, or one external normally-open device. 

LIBRA-PIR433 - 

Wireless PIR Motion Sensor. 

LIBRA-SMK433 - 

Wireless Photoelectric Supervised smoke detector. 

LIBRA-KEYF433 - 

Hand-Held Keyfob Transmitter.  Key chain/Pendant remote arming or emergency transmitter. 

LIBRA-GB433 - 

Glass-break sensor. 

DL123A - 

Replacement Lithium Battery for LIBRA-TRANS433, LIBRA-PIR433 (2), and LIBRA-GB433 (2) (bulk 

packed). 

LIBRA-RECV8-433: 

Wireless Receiver, 8 Zones  

LIBRA-RECV16-433: 

Wireless Receiver, 16 Zones  

LIBRA-RECV96-433: 

Wireless Receiver, 96 Zones (maximum 32 zones supported)

 

LIBRA-RECV255-433: 

Wireless Receiver, 255 Zones (maximum 32 zones supported) 

 
 

For Sales and Repairs, call toll free: (800) 645-9445 

For direct line to Technical Service, call toll free: (800) 645-9440 

Internet: http://www.napcosecurity.com 

Содержание LIBRA DXK4RF-319

Страница 1: ...d telephone wiring NOTE See Installation Instructions for the appropriate control panel 2 Connect AC power first and then the battery 3 Configure the keypad see page 3 4 Access the Easy Menu Driven De...

Страница 2: ...programmed time a Supervi sory Failure will result COMPATIBLE CONTROL PANELS See WI1752 for installation and programming instructions with the GEM P816 GEM P1632 GEM P3200 and GEM P9600 control panels...

Страница 3: ...ith label and felt backing affixed and handle facing forward down the guides at the rear of the keypad until it snaps into place Once installed the Sliding Label Plate cannot be removed without first...

Страница 4: ...umber to which the transmitter will be mapped the 6 digit ID Code 1 digit checksum number printed on the transmitter and box the wireless point number Note When programming the ID Code at the keypad p...

Страница 5: ...r Zone 11 3 Open the loops of points 1 and 2 4 Install the transmitter battery The keypad will beep twice to indicate that two points have been enrolled Transmitter 410078 point 1 will be mapped to Zo...

Страница 6: ...Supervisory failure Indicates that a transmitter has not checked in within the programmed timeout Check the transmitter for a dead battery see note above Also check for an object in the path of the tr...

Страница 7: ...TRY IN THE EASY PROGRAM MODE The data entered in response to an Easy Program Mode question may be reviewed before saving After entering the data before pressing u to save w may be pressed until the 2...

Страница 8: ...zone numbers which are to be used as Exit Entry zones Valid entries are from 01 to 32 Directly enter each zone number including leading zeros Use number buttons 1 through 9 NOTE Press the 0 button fo...

Страница 9: ...each zone number including leading zeros Press u to save and then repeat for any additional zone s Press NEXT r or p to proceed NOTE A chime time of 2 seconds will be automatically programmed Chime 2...

Страница 10: ...to proceed Auto Bypass Re entry Zones allow the system to be armed with the zone faulted but come back into the system armed when the zone is subsequently closed Enable No EOLR Zones New Program Only...

Страница 11: ...Press G1 through G4 for letters B E respectively Press u to save Press NEXT r or p to proceed Enter User Codes Press the w button to set cursor Enter up to 64 User Codes with User Options for each co...

Страница 12: ...0 for Blank Space 2 For User Options press 0 for Blank Space Quick Enroll Method If a receiver is already installed in the panel Napco transmitter wireless points can be programmed automatically enro...

Страница 13: ...to a maximum of 64 controlled zones can be assigned providing multiple wireless panic buttons on a system each reporting to the Central Station or a pager and or annunciating on a keypad the keyfob zo...

Страница 14: ...y to silence the keypad ZONE DESCRIPTIONS GEM DXK3 or GEM DXRP3 cannot be used to enter Zone Descriptions To enter Zone Descriptions you must use the GEM DXK1 or GEM DXRP1 keypad or the Napco Quicklo...

Страница 15: ...locations each left and right as shown in the adjacent diagram ACCESSING DIRECT ADDRESS PROGRAM MODE 1 Enter the Dealer Security Code default 456789 for a new panel or enter your custom Dealer Program...

Страница 16: ...16 This page left blank intentionally...

Страница 17: ...17 MOUNTING TEMPLATE 4 3 8 2 3 8 ANTENNA HOLE KEYPAD BUS WIRES TAMPER DO NOT CUT OR DRILL WALL...

Страница 18: ...18 NOTES...

Страница 19: ...on purporting to act on its behalf to modify to change or to assume for it any other warranty or liability concerning its products In no event shall NAPCO be liable for an amount in excess of NAPCO s...

Страница 20: ...NAPCO 2008 R 333 Bayview Avenue Amityville New York 11701 For Sales and Repairs 800 645 9445 For Technical Service 800 645 9440 Internet http www napcosecurity com Publicly traded on NASDAQ Symbol NS...

Отзывы: