background image

12 

RF Transmitter Points 

(Press the

 (

w

button to set cursor)

 

(For wireless systems only. 

 

Also see Quick Method, which follows).

 

For each transmitter (keyfob transmitters also), enter the zone number (01–64) to which the 
transmitter will be mapped, the 6-digit RF ID#: 1-digit checksum number printed on the transmitter and 
box, the point number (1–4); 

enter “9” for unsupervised

 (all points).  

NOTE:

  When programming the 

ID Code number, “A” = 

G0

; “B” = 

G1

; “C” = 

G2

; “D” = 

G3

; “E” = 

G4

; “F” = 

G5

.  Press 

u

 to save.  Press NEXT ("

r

" or 

p

) to proceed. 

Related User Options:  

“Enable Global Ambush Code” (Address 1422) & “Global 

Ambush Code” (Address 2045). 

CODE TYPE 

EXPLANATION 

Disabled 

User Code not active. 

Arm/Disarm 

Allows User Code to arm/disarm. 

Arm Only 

Prevents User Code from disarming. 

Service 

A Service Code has restricted arm/disarm rights; if an area is armed with a Service Code, 
a “

SERVICE ON

” appears on the GEM-DXRP2 keypad and the area can be disarmed with any 

valid User Code, including a Service Code. If the area is armed with OTHER than a 
Service Code, it CANNOT be disarmed with a Service Code. This is typically used to 
allow tradesmen access to premises under control of the owner. 

Access 

This is normally used to activate a door strike. Also program “Access Control on PGM2 
Output” (Address 0719) and “PGM2 Output Access Control Timeout” (Address 0711). 

Ambush 

There are two types of Ambush Codes:  (1) A 2-digit code (prefix) that is entered 
immediately prior to (and as part of) the regular User Code and (2) A separate and 
unique User Code.  Disarming with an Ambush Code will cause a silent report to be 
sent to a central station. Thus, should a user be forced to disarm, he can silently signal 
an emergency while appearing to be merely disarming the system. 

* User Program 

User Program Option is enabled for Keypad 1 only, wherever it is connected.  To enable 
User Program Option for any user add 8 to the data entry Option (see example). Then, 
User Programming can be performed only at Keypad 1 by a user code with user program 
enabled. 

Bypass Enable 

Security Bypass--Bypass is enabled only with a security code. 

USER OPTIONS:

 Area 1-4 options for 64 Us-

ers:   

Select the desired options from the table 
shown and enter in the remaining boxes 
for each user code. 

Example: 

 Program a code of “1234” for user 02, 

with Area 1 options of “Arm/Disarm” and “User 
Program”: 

 

With “27” displayed in keypad window, press 

w

0

 

2

 (User 2),

 

w

 

1234

G

 

0

 

G

 

0

 (User Code), 

09

 

(User Area 1 

options), 

00

 

(User Area 2 Options), and 

u

 (save).   

Notes: 

 (1) For 

User Code

, press 

G

 

0

 

for Blank Space; (2) For 

User Options

, press 

0

 for Blank Space.   

Quick Enroll Method

 

If a receiver is already installed in the panel, Napco transmitter 
wireless points can be programmed automatically (“enrolled”) 
using the following procedure.  

NOTE:

  The transmitter point will 

be enrolled only if the signal strength is 3 or greater. 

1.  Enter the zone number to which the transmitter point will be 

mapped. 

2.   Press  the 

x

 

button to enter the Enroll Mode.  The red 

and green LEDs on the keypad will flash and the window will 
display as shown at left. 

3.  Open the loop of the point that is to be programmed (GEM-

TRANS2 or GEM-TRANS4 only). 

4.  Install the transmitter battery.  The keypad will beep to 

indicate that the point has been successfully enrolled.  Multi-
point transmitters can be mapped to successive zones 
simultaneously (Example 1) or to selected zones point by 
point (Example 2). 

 
Example 1.  

A 4-point transmitter has the RF ID number 

410078:1. 

 

Map the first three points to Zones 11–13, 

respectively. 

1.   Enter the Enroll mode as described in step 2 above. 
2.   Enter Zone “11”. 

3.   Open the loops of points 1, 2 and 3. 
4.   Install the transmitter battery.  The keypad will beep 3 times 

to indicate that three points have been programmed. 

Transmitter 410078:1, point 1 will be mapped to Zone 11. 

Transmitter 410078:1, point 2 will be mapped to Zone 12. 

Transmitter 410078:1, point 3 will be mapped to Zone 13. 

The keypad will now display Zone 13, the last zone enrolled. 

 
Example 2.

  A 2-point transmitter has the RF ID number 

287613:1. 

 

Map point 1 to Zone 6 and point 2 to Zone 9. 

 

1.   Enter the Enroll mode as described above. 
2.   Enter Zone “06”. 
3.   Open point-1 loop. 
4.   Install the battery.  The keypad will beep once to indicate 

that one point has been programmed.  (Transmitter 
287613:1, point 1 will be mapped to Zone 6). 

5.   Enter Zone “09”. 
6.   Close point-1 loop and open point-2 loop. 
7. 

  Remove the transmitter battery, then re-install it.  The 

keypad will beep once to indicate that one point has been 
programmed.  (Transmitter 287613:1, point 2 is mapped to 
Zone 9). 

CHANGING OR CANCELING A CODE:

  To change 

any code, merely program over the existing code as 

described above and press 

u

 

to save. Similarly, to 

cancel a code, blank out each number of the code 

and press 

u

 

to save.  

Note:  

Duplicate User Codes 

are not allowed; therefore a duplicate Code entered in the 

LCD Window will erase when 

u

 is pressed.   

USER OPTIONS  

USER CODE 

(UP TO 6 DIGITS)  

AREA 1 

OPTIONS  

AREA 2 

OPTIONS  

AREA 3 

OPTIONS  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AREA 4 

OPTIONS  

USER AREA OPTIONS 

DATA ENTRIES 

blank(•) 

blank(•) 

Disabled 

blank(•) 

Arm/Disarm 

blank(•) 

Arm Only 

blank(•) 

Service 

blank(•) 

Access 

blank(•) 

Ambush 

blank(•) 

Add 8 

* User Program 

blank(•) 

Bypass Enable 

OPTION 

ENABLED 

28 

Содержание LIBRA DXK4RF-319

Страница 1: ...d telephone wiring NOTE See Installation Instructions for the appropriate control panel 2 Connect AC power first and then the battery 3 Configure the keypad see page 3 4 Access the Easy Menu Driven De...

Страница 2: ...programmed time a Supervi sory Failure will result COMPATIBLE CONTROL PANELS See WI1752 for installation and programming instructions with the GEM P816 GEM P1632 GEM P3200 and GEM P9600 control panels...

Страница 3: ...ith label and felt backing affixed and handle facing forward down the guides at the rear of the keypad until it snaps into place Once installed the Sliding Label Plate cannot be removed without first...

Страница 4: ...umber to which the transmitter will be mapped the 6 digit ID Code 1 digit checksum number printed on the transmitter and box the wireless point number Note When programming the ID Code at the keypad p...

Страница 5: ...r Zone 11 3 Open the loops of points 1 and 2 4 Install the transmitter battery The keypad will beep twice to indicate that two points have been enrolled Transmitter 410078 point 1 will be mapped to Zo...

Страница 6: ...Supervisory failure Indicates that a transmitter has not checked in within the programmed timeout Check the transmitter for a dead battery see note above Also check for an object in the path of the tr...

Страница 7: ...TRY IN THE EASY PROGRAM MODE The data entered in response to an Easy Program Mode question may be reviewed before saving After entering the data before pressing u to save w may be pressed until the 2...

Страница 8: ...zone numbers which are to be used as Exit Entry zones Valid entries are from 01 to 32 Directly enter each zone number including leading zeros Use number buttons 1 through 9 NOTE Press the 0 button fo...

Страница 9: ...each zone number including leading zeros Press u to save and then repeat for any additional zone s Press NEXT r or p to proceed NOTE A chime time of 2 seconds will be automatically programmed Chime 2...

Страница 10: ...to proceed Auto Bypass Re entry Zones allow the system to be armed with the zone faulted but come back into the system armed when the zone is subsequently closed Enable No EOLR Zones New Program Only...

Страница 11: ...Press G1 through G4 for letters B E respectively Press u to save Press NEXT r or p to proceed Enter User Codes Press the w button to set cursor Enter up to 64 User Codes with User Options for each co...

Страница 12: ...0 for Blank Space 2 For User Options press 0 for Blank Space Quick Enroll Method If a receiver is already installed in the panel Napco transmitter wireless points can be programmed automatically enro...

Страница 13: ...to a maximum of 64 controlled zones can be assigned providing multiple wireless panic buttons on a system each reporting to the Central Station or a pager and or annunciating on a keypad the keyfob zo...

Страница 14: ...y to silence the keypad ZONE DESCRIPTIONS GEM DXK3 or GEM DXRP3 cannot be used to enter Zone Descriptions To enter Zone Descriptions you must use the GEM DXK1 or GEM DXRP1 keypad or the Napco Quicklo...

Страница 15: ...locations each left and right as shown in the adjacent diagram ACCESSING DIRECT ADDRESS PROGRAM MODE 1 Enter the Dealer Security Code default 456789 for a new panel or enter your custom Dealer Program...

Страница 16: ...16 This page left blank intentionally...

Страница 17: ...17 MOUNTING TEMPLATE 4 3 8 2 3 8 ANTENNA HOLE KEYPAD BUS WIRES TAMPER DO NOT CUT OR DRILL WALL...

Страница 18: ...18 NOTES...

Страница 19: ...on purporting to act on its behalf to modify to change or to assume for it any other warranty or liability concerning its products In no event shall NAPCO be liable for an amount in excess of NAPCO s...

Страница 20: ...NAPCO 2008 R 333 Bayview Avenue Amityville New York 11701 For Sales and Repairs 800 645 9445 For Technical Service 800 645 9440 Internet http www napcosecurity com Publicly traded on NASDAQ Symbol NS...